Performance of functional materials and components in a fusion reactor: the issue of radiation effects in ceramics and glass materials for diagnostics

被引:59
作者
Decreton, M
Shikama, T
Hodgson, E
机构
[1] CEN SCK, Fus Res Unit, Belgian Nucl Res Ctr, B-2400 Mol, Belgium
[2] Tohoku Univ, Inst Mat Sci, Sendai, Miyagi 980, Japan
[3] CIEMAT, E-28040 Madrid, Spain
关键词
D O I
10.1016/j.jnucmat.2004.04.012
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Reliable plasma diagnostics systems are key elements for an efficient operation of future fusion reactors. They represent a major challenge, as existing systems must be upgraded to the harsh environment of a burning plasma and to the stringent requirements of real-time control actions. Radiation effects bring in this respect specific constraints. The front ends of most of the diagnostics systems are inside the vacuum vessel, and therefore subject to intense neutron and gamma radiations. These systems use particular components, such as ceramic insulators, dielectric and optical windows, optical fibres and complete sensor assemblies. Studying radiation effects for these components requires particular attention to the material choice and a specific methodology. The paper makes a review of the research performed worldwide on this subject and discusses the state of the art and the future priorities to be set. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:125 / 132
页数:8
相关论文
共 66 条
[1]  
ADAMS L, 2002, HDB RAD EFFECTS
[2]  
ALLAN C, 1980, IEEE T, P764
[3]   Investigation of RIEMF nature in magnetic sensors for ITER [J].
Bender, SE ;
Chernov, VM ;
Demenkov, PV ;
Plaksin, OA ;
Stepanov, VA .
FUSION ENGINEERING AND DESIGN, 2001, 56-57 (56-57) :911-915
[4]   Round-robin evaluation of optical fibres for plasma diagnostics [J].
Brichard, B ;
Van Uffelen, M ;
Fernandez, AF ;
Berghmans, F ;
Decréton, M ;
Hodgson, E ;
Shikama, T ;
Kakuta, T ;
Tomashuk, A ;
Golant, K ;
Krasilnikov, A .
FUSION ENGINEERING AND DESIGN, 2001, 56-57 :917-921
[5]  
BRICHARD B, 2003, IEEE T, P2024
[6]  
BRICHARD B, UNPUB
[7]  
BRICHARD B, 2002, R3699 SCK CEN
[8]   Optical absorption and luminescence of 14-MeV neutron-irradiated CaF2 single crystals [J].
Cooke, DW ;
Bennett, BL .
JOURNAL OF NUCLEAR MATERIALS, 2003, 321 (2-3) :158-164
[9]  
Costley AE, 2002, ADVANCED DIAGNOSTICS FOR MAGNETIC AND INERTIAL FUSION, P1
[10]   ITER R&D: Auxiliary systems: Plasma diagnostics [J].
Costley, AE ;
Campbell, DJ ;
Kasai, S ;
Young, KE ;
Zaveriaev, V .
FUSION ENGINEERING AND DESIGN, 2001, 55 (2-3) :331-346