Investigation on the Accuracy of Approximate Solutions Obtained by Perturbation Method for Galloping Equation of Iced Transmission Lines

被引:6
|
作者
Liu, Xiaohui [1 ]
Yang, Shuguang [2 ]
Min, Guangyun [2 ]
Cai, Mengqi [3 ]
Wu, Chuan [4 ]
Jiang, Yantao [1 ]
机构
[1] Chongqing Jiaotong Univ, State Key Lab Mt Bridge & Tunnel Engn, Chongqing 400074, Peoples R China
[2] Chongqing Jiaotong Univ, Sch Civil Engn, Chongqing 400074, Peoples R China
[3] Chengdu Univ, Sch Architecture & Civil Engn, Chengdu 610106, Peoples R China
[4] State Grid Henan Elect Power Res Inst, Zhengzhou 450052, Peoples R China
基金
中国博士后科学基金; 中国国家自然科学基金;
关键词
All Open Access; Gold;
D O I
10.1155/2021/6651629
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Perturbation method is a commonly used method to solve galloping equation of iced transmission lines, but few scholars have studied the influences of perturbation method on the accuracy of approximate solutions of the galloping equation. In order to analyze the accuracy of approximate solutions obtained by perturbation method for galloping equation of iced transmission lines, the partial differential galloping equation of iced transmission lines with quadratic and cubic nonlinear terms is obtained firstly. Then, the partial differential galloping equation is transformed into ordinary differential galloping equation by Galerkin method. Finally, the approximate solutions of the partial differential galloping equation are obtained by averaging method and first-order, second-order, third-order, and fourth-order multiple scales methods, and the results obtained by these methods are compared systematically. By comparing the numerical solutions and the approximate solutions obtained by averaging method, it can be found that, with the increasing in wind velocity and Young's modulus of iced transmission lines, the nonlinearity of the system would strengthen and the drift of the vibration center of the system would also increase. The larger the drift is, the greater the error between the approximate solutions obtained by averaging method and the numerical solutions will be. And when the wind velocity reaches 32 m/s, the error would arrive at 17.321%. By comparing the numerical solutions and the approximate solutions obtained by the first-order, the second-order, the third-order, and the fourth-order multiple scales methods, it can be concluded that the first-order multiple scales method is less complex computationally. The accuracy of approximate solutions obtained by the fourth-order multiple scales method is better than that obtained by the first-order, the second-order, and the third-order multiple scales methods, and the error between the approximate solutions obtained by the fourth-order multiple scales method and the numerical solutions is less than 0.639%. The conclusions obtained in this paper would be helpful to the solutions of galloping equation of iced transmission lines and could also give some references to practical engineering.
引用
收藏
页数:18
相关论文
共 50 条
  • [1] Analysis on galloping models of iced transmission lines
    You Yi
    Yan Zhi-tao
    Wang Ling-zhi
    Li Peng
    PROCEEDINGS OF THE 2017 2ND INTERNATIONAL CONFERENCE ON CIVIL, TRANSPORTATION AND ENVIRONMENTAL ENGINEERING (ICCTE 2017), 2017, 135 : 147 - 151
  • [2] Two Simplified Methods for Galloping of Iced Transmission Lines
    Liu, Xiaohui
    Min, Guangyun
    Cai, Mengqi
    Yan, Bo
    Wu, Chuan
    KSCE JOURNAL OF CIVIL ENGINEERING, 2021, 25 (01) : 272 - 290
  • [3] Two Simplified Methods for Galloping of Iced Transmission Lines
    Xiaohui Liu
    Guangyun Min
    Mengqi Cai
    Bo Yan
    Chuan Wu
    KSCE Journal of Civil Engineering, 2021, 25 : 272 - 290
  • [4] Matrix perturbation method for analysis of 3 DOF iced transmission line galloping mechanism
    Jiang X.
    Lou W.-J.
    Zhendong Gongcheng Xuebao, 6 (1070-1078): : 1070 - 1078
  • [5] Study on galloping behavior of iced eight bundle conductor transmission lines
    Zhou, Linshu
    Yan, Bo
    Zhang, Liang
    Zhou, Song
    JOURNAL OF SOUND AND VIBRATION, 2016, 362 : 85 - 110
  • [6] Dynamic aerodynamic characteristics of the galloping of bundled iced power transmission lines
    Li, Wanping
    Kongqi Donglixue Xuebao/Acta Aerodynamica Sinica, 2000, 18 (04): : 413 - 420
  • [7] Nonlinear galloping of internally resonant iced transmission lines considering eccentricity
    Yan, Zhimiao
    Yan, Zhitao
    Li, Zhengliang
    Tan, Ting
    JOURNAL OF SOUND AND VIBRATION, 2012, 331 (15) : 3599 - 3616
  • [8] WIND TUNNEL STUDIES ON THE GALLOPING OF LIGHTLY-ICED TRANSMISSION LINES
    Fleming, Patrick H.
    Popplewell, Neil
    PROCEEDINGS OF THE ASME FLUIDS ENGINEERING DIVISION SUMMER MEETING - 2010 - VOL 3, PTS A AND B, 2010, : 155 - 164
  • [9] Study on galloping control of iced four split conduction transmission lines
    Liu, Chuncheng
    Jiang, Tao
    Wang, Meng
    Zhendong yu Chongji/Journal of Vibration and Shock, 2024, 43 (24): : 1 - 13
  • [10] Analysis of Transverse-Torsional Coupling Galloping Trajectory of Iced Transmission Lines
    Li, G. Q.
    Zhu, H.
    Han, Z. B.
    Guo, J. X.
    Zhang, G. H.
    Shan, F. X.
    Su, Y. H.
    Liu, Y. H.
    Cheng, S. C.
    Liu, Y. J.
    STRENGTH OF MATERIALS, 2024, 56 (04) : 898 - 906