Three-Dimensional Analysis of MgB2 Wire by use of X-ray Micro-Tomography

被引:6
|
作者
Inoue, Masayoshi [1 ]
Tatara, Hiroshi [1 ]
Harada, Kazutaka [1 ]
Higashikawa, Kohei [1 ]
Ye, Shujun [2 ]
Matsumoto, Akiyoshi [2 ]
Kumakura, Hiroaki [2 ]
Kiss, Takanobu [1 ]
机构
[1] Kyushu Univ, Grad Sch Informat Sci & Elect Engn, Dept Elect Engn, Fukuoka 8190395, Japan
[2] Natl Inst Mat Sci, Tsukuba, Ibaraki 3050047, Japan
基金
日本科学技术振兴机构;
关键词
Internal magnesium diffusion process; MgB2; non-destructive inspection; X-ray micro-tomography; TAPES;
D O I
10.1109/TASC.2016.2542738
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
For the further development of MgB2 wires, investigation of 3-D structures for MgB2 filaments and sheath materials is important. However, typical cross-sectional observation such as optical microscopy and scanning electron microscopy are essentially 2-D, therefore, not enough to understand the 3-D filament structures. In this paper, we have adopted X-ray microtomography and carried out a 3-D analysis for MgB2 wire. X-ray microtomography (Skyscan 1172, Bruker) allows us to visualize the internal filament structure of a centimeter-long MgB2 wire with a high spatial resolution of 1.1 mu m, with a nondestructive manner. We investigated the boundary between the sheath material and the MgB2 filament of an internal Mg-diffusion-processed MgB2 wire. Furthermore, by improving the signal-to-noise ratio for the X-ray microtomography, we have also identified the boundary between the MgB2 filament and the hole (air) in spite of the low X-ray absorption coefficient for boron and magnesium. From the 3-D analysis, we can reveal the shape and area of MgB2 filament quantitatively and also their statistical distribution.
引用
收藏
页数:4
相关论文
共 50 条
  • [41] Micro-tomography based Geometry Modeling of Three-Dimensional Braided Composites
    Fang, Guodong
    Chen, Chenghua
    Yuan, Shenggang
    Meng, Songhe
    Liang, Jun
    APPLIED COMPOSITE MATERIALS, 2018, 25 (03) : 469 - 483
  • [42] X-ray micro-tomography of a coronary stent deployed in a model artery
    Connolley, Thomas
    Nash, Derek
    Buffiere, Jean-Yves
    Sharif, Faisal
    McHugh, Peter Edward
    MEDICAL ENGINEERING & PHYSICS, 2007, 29 (10) : 1132 - 1141
  • [43] Laboratory-based x-ray micro-tomography with submicron resolution
    Mayo, S.
    Miller, P.
    Wilkins, S. W.
    Gao, D.
    Gureyev, T.
    DEVELOPMENTS IN X-RAY TOMOGRAPHY V, 2006, 6318
  • [44] X-ray micro-tomography for investigations of brain tissues on cellular level
    Khimchenko, Anna
    Schulz, Georg
    Deyhle, Hans
    Thalmann, Peter
    Zanette, Irene
    Zdora, Marie-Christine
    Bikis, Christos
    Hipp, Alexander
    Hieber, Simone E.
    Schweighauser, Gabriel
    Hench, Juergen
    Mueller, Bert
    DEVELOPMENTS IN X-RAY TOMOGRAPHY X, 2016, 9967
  • [45] Three-Dimensional Analysis of the Porosity in MgB2 Wires Using FIB Nanotomography
    Hagner, M.
    Fritz, J. M.
    Alknes, P.
    Scheuerlein, C.
    Zielke, L.
    Vierrath, S.
    Thiele, S.
    Bordini, B.
    Ballarino, A.
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2016, 26 (03)
  • [46] Superior techniques for eliminating ring artifacts in X-ray micro-tomography
    Vo, Nghia T.
    Atwood, Robert C.
    Drakopoulos, Michael
    OPTICS EXPRESS, 2018, 26 (22): : 28396 - 28412
  • [47] X-ray micro-tomography an attractive characterisation technique in materials science
    Salvo, L
    Cloetens, P
    Maire, E
    Zabler, S
    Blandin, JJ
    Buffière, JY
    Ludwig, W
    Boller, E
    Bellet, D
    Josserond, C
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2003, 200 : 273 - 286
  • [48] High Resolution X-ray Micro-Tomography of the Posterior Ampullary Nerve
    Labrousse, Marc
    Blanchot, Delphine
    Dubernard, Xavier
    Settembre, Nicla
    Avisse, Claude
    Devy, Jerome
    Renard, Yohann
    FASEB JOURNAL, 2018, 32 (01):
  • [49] Dose fractionation in synchrotron radiation x-ray phase micro-tomography
    Frachon, Thibaut
    Weber, Loriane
    Hesse, Bernhard
    Rit, Simon
    Dong, Pei
    Olivier, Cecile
    Peyrin, Francoise
    Langer, Max
    PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (19): : 7543 - 7566
  • [50] Fast X-ray micro-tomography for low-Z materials
    Xu, L.
    Chen, R.
    Du, G.
    Xie, H.
    Xiao, T.
    JOURNAL OF INSTRUMENTATION, 2015, 10