Effect of Low-Intensity Pulsed Ultrasound on Distraction Osteogenesis Treatment Time A Meta-analysis of Randomized Clinical Trials

被引:21
|
作者
Raza, Hasnain [1 ]
Saltaji, Humam [2 ]
Kaur, Harmanpreet [1 ]
Flores-Mir, Carlos [3 ]
El-Bialy, Tarek [3 ]
机构
[1] Univ Alberta, Sch Dent, Edmonton, AB T6G 2E1, Canada
[2] Univ Alberta, Sch Dent, Orthodont Grad Program, Edmonton, AB T6G 2E1, Canada
[3] Univ Alberta, Sch Dent, Div Orthodont, Edmonton, AB T6G 2E1, Canada
关键词
distraction osteogenesis; low intensity-pulsed ultrasound; musculoskeletal ultrasound; therapeutic ultrasound; BONE-FORMATION; CALLUS; MATURATION; CONSOLIDATION; ENHANCEMENT; ADJUVANT;
D O I
10.7863/ultra.15.02043
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Objectives-The objectives of this systematic review with a meta-analysis were to critically analyze the available scientific literature regarding the effects of low-intensity pulsed ultrasound (US) on stimulating bone regeneration and bone maturation during distraction osteogenesis in humans and to determine whether the stimulatory effect of low-intensity pulsed US can effectively reduce the associated treatment time. Methods-Studies were considered for inclusion if they were randomized clinical trials that examined the effect of low-intensity pulsed US on distraction osteogenesis compared to conventional distraction osteogenesis. The primary outcome was reduced treatment time. Study selection, risk of bias assessment, and data extraction were performed in duplicate. A random-effects meta-analysis model was used when more than 3 trials were eligible for a quantitative analysis and considering the expected differences in interventions and measurement tools. Results-Five randomized clinical trials, with a moderate to high risk of bias, met the eligibility criteria. Four trials examining tibial distraction osteogenesis in 118 patients were combined in a meta-analysis. A statistically significant difference for reduced treatment time between distraction osteogenesis with low-intensity pulsed US and standard distraction osteogenesis was evident (mean difference, -15.236 d/cm; random-effects 95% confidence interval, -19.902 to -10.569 d/cm; P < .0001). As for the mandible, only 1 clinical trial was available, which showed no significant effect of low-intensity pulsed US therapy on distraction osteogenesis. Conclusions-Current available evidence suggests that low-intensity pulsed US therapy may provide a reduction in the overall treatment time for tibial distraction osteogenesis. However, this conclusion should be considered with caution, given the moderate to high risk of bias in the included randomized clinical trials.
引用
收藏
页码:349 / 358
页数:10
相关论文
共 50 条
  • [31] Effect of low-intensity pulsed ultrasound on postoperative rehabilitation of rotator cuff tears: Protocol for a systematic review and meta-analysis
    Xue, Xiali
    Kuati, Amila
    Fu, Hao
    Song, Qingfa
    Liu, Qiang
    Cui, Guoqing
    PLOS ONE, 2024, 19 (08):
  • [32] Low-intensity pulsed ultrasound in the conservative treatment of pseudoarthrosis
    Pigozzi, F
    Moneta, MR
    Giombini, A
    Giannini, S
    Di Cesare, A
    Fagnani, F
    Mariani, PP
    JOURNAL OF SPORTS MEDICINE AND PHYSICAL FITNESS, 2004, 44 (02): : 173 - 178
  • [33] Low-intensity pulsed ultrasound does not enhance distraction callus in a rabbit model
    Taylor, Kenneth F.
    Rafiee, Bahman
    Tis, John E.
    Inoue, Nozumu
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2007, (459) : 237 - 245
  • [34] Healing of fracture nonunions treated with low-intensity pulsed ultrasound (LIPUS): A systematic review and meta-analysis
    Leighton, Ross
    Watson, J. Tracy
    Giannoudis, Peter
    Papakostidis, Costas
    Harrison, Andrew
    Steen, R. Grant
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2017, 48 (07): : 1339 - 1347
  • [35] The effect of low intensity pulsed ultrasound applied to rabbit tibiae during the consolidation phase of distraction osteogenesis
    Tis, JE
    Meffert, RH
    Inoue, N
    McCarthy, EF
    Machen, MS
    McHale, KA
    Chao, EYS
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2002, 20 (04) : 793 - 800
  • [36] Enhanced Bone Regeneration by Bone Morphogenetic Protein-2 after Pretreatment with Low-Intensity Pulsed Ultrasound in Distraction Osteogenesis
    Han, Jeong Joon
    Yang, Hoon Joo
    Hwang, Soon Jung
    TISSUE ENGINEERING AND REGENERATIVE MEDICINE, 2022, 19 (04) : 871 - 886
  • [37] Enhanced Bone Regeneration by Bone Morphogenetic Protein-2 after Pretreatment with Low-Intensity Pulsed Ultrasound in Distraction Osteogenesis
    Jeong Joon Han
    Hoon Joo Yang
    Soon Jung Hwang
    Tissue Engineering and Regenerative Medicine, 2022, 19 : 871 - 886
  • [38] Application of low intensity, pulsed ultrasound on distraction osteogenesis of the humerus. Case report
    Dudda, M
    Pommer, A
    Muhr, G
    Esenwein, SA
    UNFALLCHIRURG, 2005, 108 (01): : 69 - 74
  • [39] High-intensity electroacupuncture is superior to low-intensity electroacupuncture for knee osteoarthritis: a meta-analysis of randomized controlled trials
    Yuan, Shi-Guo
    Chen, Jung
    Chen, Mei-Xiong
    Zheng, Nan-Sheng
    Zhang, Zhi-Wei
    Wang, Hua-Jun
    Li, Jia
    Li, Ling
    Gao, Yan-Ping
    ACUPUNCTURE IN MEDICINE, 2024, 42 (06) : 303 - 310
  • [40] Low-intensity pulsed ultrasound in the treatment of nonunions - Editorial comment
    Ziran, BH