Reference measurements of cadmium and lead contents in candidates for new environmental certified materials by isotope dilution inductively coupled plasma mass spectrometry

被引:23
作者
Krata, Agnieszka Anna [1 ]
Wojciechowski, Marcin [1 ]
Kalabun, Mateusz [1 ,2 ]
Bulska, Ewa [1 ]
机构
[1] Univ Warsaw, Fac Chem, Biol & Chem Res Ctr, Zwirki & Wigury 101, PL-02089 Warsaw, Poland
[2] Univ Warsaw, Interfac Interdisciplinary Doctoral Studies Nat, Zwirki & Wigury 93, PL-02089 Warsaw, Poland
关键词
New environmental reference material; Isotope dilution; Mass spectrometry; Cadmium; Lead; Quality control; ICP-MS; UNCERTAINTY CONTRIBUTIONS; MERCURY; COAST; CERTIFICATION; FRACTIONS; COPPER; ZINC;
D O I
10.1016/j.microc.2018.06.013
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The analytical procedures for the reference measurements of cadmium and lead concentrations in four candidates for new environmental certified reference materials were developed. Cadmium and lead content was determined in bottom sediment (M-2 BotSed), Baltic herring tissue (M-3 HerTis), cormorant tissue (M-4 CormTis) and codfish tissue (M-5 CodTis). The measurements were carried out with the use of a direct isotope dilution inductively coupled plasma mass spectrometry (ID ICP-MS). The isotope dilution approach and the combined uncertainty of results are based on the mathematical equations as from definition of a primary method of measurement. All factors influencing the final results included: the procedural blank, the moisture content in the materials, the factors affecting the blend ratio measurements (instrumental background, spectral interferences, dead time, mass discrimination effects and the repeatability of measured isotopic ratios) as well as the isotopic equilibrium were systematically investigated and included in the uncertainty budget. The content of cadmium in candidates for new environmental reference materials, after correction for moisture contents, matrix separation on ion-exchange resin AG1-X8 of the blended samples and after using for the ICP-MS measurements ratio of pair of isotopes n(110Cd)/n(111Cd) was found to be: (2.18 +/- 0.06) mu g g(-1) in M-2 BotSed, (337 +/- 2) ng g(-1) in HerTis, (16.4 +/- 0.6) ng g(-1) in CormTis) and (2.7 +/- 0.4) ng g(-1) in CodTis, respectively. The content of lead in candidates for new environmental reference materials, after correction for moisture contents, matrix separation on ion-exchange resin AG1-X8 of the blended samples and after using for the ICP-MS measurements ratio of pair of isotopes n(Pb-208)/n(Pb-207) was found to be: (108 +/- 5) ng g(-1) in M-3 HerTis, (2.34 +/- 0.12) mu g g(-1) in M-4 CormTis and (43 +/- 2) ng g(-1) in M-5 CodTis, respectively. The Cd and Pb contents determined in this work were used as a contribution of the Faculty of Chemistry, Biological and Chemical Research Centre University of Warsaw in the characterisation of the abovementioned candidates for new certified reference materials in the frame of the Inter-Laboratory Comparison, organized by the Institute Nuclear Chemistry and Technology (Warsaw, Poland). The obtained excellent agreement within uncertainties with the reference values further validated the methods developed in this study.
引用
收藏
页码:36 / 42
页数:7
相关论文
共 50 条
  • [41] Orthodox uncertainty budgeting for high accuracy measurements by isotope dilution inductively coupled plasma-mass spectrometry
    Briche, CSJW
    Harrington, C
    Catterick, T
    Fairman, B
    ANALYTICA CHIMICA ACTA, 2001, 437 (01) : 1 - 10
  • [42] Determination of mercury in fish by isotope dilution inductively coupled plasma-mass spectrometry
    Wang Meng
    Zhang Yu
    Feng Wei-Yue
    Guan Ming
    Wang Bing
    Shi Jun-Wen
    Zhu Mo-Tao
    Li Bai
    Zhao Yu-Liang
    Chai Zhi-Fang
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2007, 35 (07) : 945 - 948
  • [43] Certification of Ca, Mg, and K in human plasma reference material using isotope dilution inductively coupled plasma mass spectrometry
    Baharom, Norliza
    Yim, Yong-Hyeon
    BULLETIN OF THE KOREAN CHEMICAL SOCIETY, 2021, 42 (12) : 1593 - 1601
  • [44] Determination of germanium by isotope dilution hydride generation inductively coupled plasma mass spectrometry
    Mortlock, RA
    Froelich, PN
    ANALYTICA CHIMICA ACTA, 1996, 332 (2-3) : 277 - 284
  • [45] Determination of Platinum Group Elements in Fall Dust by Isotope Dilution Inductively Coupled Plasma Mass Spectrometry
    Zhu Yan
    Li Xiao-Lin
    Li Yu-Lan
    Gao Song
    Xu Qi
    Wang Zheng
    Tan Ming-Guang
    Li Yan
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2011, 39 (05) : 695 - 699
  • [46] Uncertainty evaluation in reference material characterization by double isotope dilution inductively coupled plasma mass spectrometry (ID-ICP-MS)
    Lee, Jong Wha
    METROLOGIA, 2022, 59 (06)
  • [47] SOFTWARE SOLUTION FOR POST-COLUMN ISOTOPE DILUTION LIQUID CHROMATOGRAPHY-INDUCTIVELY COUPLED PLASMA MASS SPECTROMETRY
    Kana, Antonin
    Koplik, Richard
    Eichler, Stepan
    Mestek, Oto
    ANALYTICAL LETTERS, 2013, 46 (15) : 2430 - 2443
  • [48] Determination of Pb in lipsticks by flow injection chemical vapor generation isotope dilution inductively coupled plasma mass spectrometry
    Chen, Wei-Ni
    Jiang, Shiuh-Jen
    Chen, Yen-Ling
    Sahayam, A. C.
    MICROCHEMICAL JOURNAL, 2015, 119 : 128 - 132
  • [49] Accurate determination of lead in Chinese herbs using isotope dilution inductively coupled plasma mass spectrometry (ID-ICP-MS)
    Lam, James Chung-wah
    Chan, Kam-kit
    Yip, Yiu-chung
    Tong, Wai-fong
    Sin, Della Wai-mei
    FOOD CHEMISTRY, 2010, 121 (02) : 552 - 560
  • [50] On-line electrolytic dissolution for lead determination in high-purity copper by isotope dilution inductively coupled plasma mass spectrometry
    Packer, AP
    Gervasio, APG
    Miranda, CES
    Reis, BF
    Menegário, AA
    Giné, MF
    ANALYTICA CHIMICA ACTA, 2003, 485 (02) : 145 - 153