Synthesis of new copper nanoparticle-decorated anchored type ligands: Applications as non-enzymatic electrochemical sensors for hydrogen peroxide

被引:25
|
作者
Ensafi, Ali A. [1 ]
Zandi-Atashbar, N. [1 ]
Ghiaci, M. [1 ]
Taghizadeh, M. [1 ]
Rezaei, B. [1 ]
机构
[1] Isfahan Univ Technol, Dept Chem, Esfahan 8415683111, Iran
来源
MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS | 2015年 / 47卷
关键词
Cu nanoparticles-decorated anchored type ligands; Modified electrodes; Hydrogen peroxide detection; Electrocatalytic; Amperometry; HORSERADISH-PEROXIDASE; CARBON NANOTUBE; SENSITIVE DETERMINATION; SILVER NANOPARTICLES; GRAPHENE NANOSHEETS; AMPEROMETRIC SENSOR; GOLD NANOPARTICLES; PRUSSIAN BLUE; LIVING CELLS; BIOSENSOR;
D O I
10.1016/j.msec.2014.11.042
中图分类号
TB3 [工程材料学]; R318.08 [生物材料学];
学科分类号
0805 ; 080501 ; 080502 ;
摘要
In this work, copper nanoparticles (CuNPs) decorated on two new anchored type ligands were utilized to prepare two electrochemical sensors. These ligands are made from bonding amine chains to silica support including SiO2-pro-NH2 (compound I) and SiO2-pro-NH-cyanuric-NH2 (compound II). The morphology of synthesized CuNPs was characterized by transmission electron microscopy (TEM). The nano-particles were in the range of 13-37 nm with the average size of 23 nm. These materials were used to modify carbon paste electrode. Different electrochemical techniques, including cyclic voltammetry, electrochemical impedance spectroscopy and hydrodynamic chronoamperometry, were used to study the sensor behavior. These electrochemical sensors were used as a model for non-enzymatic detection of hydrogen peroxide (H2O2). To evaluate the abilities of the modified electrodes for H2O2 detection, the electrochemical signals were compared in the absence and presence of H2O2. From them, two modified electrodes showed significant responses vs. H2O2 addition. The amperograms illustrated that the sensors were selective for H2O2 sensing with linear ranges of 5.14-1250 mu mol L-1 and 1.14-1120 mu mol L-1 with detection limits of 0.85 and 0.27 mu mol L-1 H2O2, sensitivities of 3545 and 11,293 mu A mmol(-1) Land with response times less than 5 s for I/CPE and II/CPE, respectively. As further verification of the selected sensor, H2O2 contained in milk sample was analyzed and the obtained results were comparable with the ones from classical control titration method. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:290 / 297
页数:8
相关论文
共 50 条
  • [1] Non-Enzymatic Electrochemical Sensor Based on Sliver Nanoparticle-Decorated Carbon Nanotubes
    Xu, Dongqing
    Hou, Bingbing
    Qian, Lisheng
    Zhang, Xueji
    Liu, Guodong
    MOLECULES, 2019, 24 (18):
  • [2] Electrochemical determination of hydrogen peroxide using copper/porous silicon based non-enzymatic sensor
    Ensafi, Ali A.
    Abarghoui, M. Mokhtari
    Rezaei, B.
    SENSORS AND ACTUATORS B-CHEMICAL, 2014, 196 : 398 - 405
  • [3] Green synthesis of silver nanoparticle-decorated porous reduced graphene oxide for antibacterial non-enzymatic glucose sensors
    Le Thuy Hoa
    Ngo Thi Yen Linh
    Chung, Jin Suk
    Hur, Seung Hyun
    IONICS, 2017, 23 (06) : 1525 - 1532
  • [4] A simple non-enzymatic strategy for adenosine triphosphate electrochemical aptasensor using silver nanoparticle-decorated graphene oxide
    Mashhadizadeh, Mohammad Hossein
    Naseri, Niloofar
    Mehrgardi, Masoud A.
    JOURNAL OF THE IRANIAN CHEMICAL SOCIETY, 2017, 14 (09) : 2007 - 2016
  • [5] Non-enzymatic electrochemical sensors for the detection of hydrogen peroxide based on Cu2O/Cu nanocomposites
    Luo, Binbin
    Li, Xueming
    Yang, Jianchun
    Li, Xianli
    Xue, Longping
    Li, Xiaolin
    Gu, Jiakun
    Wang, Mengzhen
    Jiang, Lu
    ANALYTICAL METHODS, 2014, 6 (04) : 1114 - 1120
  • [6] Ferrocene-grafted carbon nanotubes for sensitive non-enzymatic electrochemical detection of hydrogen peroxide
    Wu, Bo
    Yeasmin, Sanjida
    Liu, Ye
    Cheng, Li-Jing
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2022, 908
  • [7] Synthesis of PtxSn/MWCNTs and their Application in Non-enzymatic Glucose and Hydrogen Peroxide Sensors
    Min, Hui
    Wu, Wenqin
    Wu, Huimin
    Wang, Shengfu
    Feng, Chuanqi
    Ding, Yu
    ELECTROANALYSIS, 2017, 29 (03) : 730 - 738
  • [8] A simple non-enzymatic strategy for adenosine triphosphate electrochemical aptasensor using silver nanoparticle-decorated graphene oxide
    Mohammad Hossein Mashhadizadeh
    Niloofar Naseri
    Masoud A. Mehrgardi
    Journal of the Iranian Chemical Society, 2017, 14 : 2007 - 2016
  • [9] Non-Enzymatic Electrochemical Hydrogen Peroxide Sensor Based on Copper Oxide Hollow Microspheres
    Shuai, Ying
    Liu, Chuanghua
    Wang, Jia
    Ma, Jun
    Cui, Xiaoyan
    SENSOR LETTERS, 2013, 11 (10) : 1945 - 1949
  • [10] Bimetallic PdCu/SPCE non-enzymatic hydrogen peroxide sensors
    Uzunoglu, Aytekin
    Scherbarth, Austin D.
    Stanciu, Lia A.
    SENSORS AND ACTUATORS B-CHEMICAL, 2015, 220 : 968 - 976