EIS analysis on the corrosion resistance of X80 steel under AC interference in simulated soil solution

被引:4
|
作者
Li, Zhong [1 ]
Sun, Baozhuang [2 ]
Pan, Yue [2 ]
Huang, Liang [2 ]
机构
[1] Chinese Soc Corros & Protect, CSCP, Beijing 100083, Peoples R China
[2] Univ Sci & Technol Beijing, Minist Educ, Corros & Protect Ctr, Key Lab Corros & Protect, Beijing 100083, Peoples R China
来源
INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE | 2021年 / 16卷 / 06期
关键词
AC corrosion; pipeline steel; EIS; charge transfer resistance; ALTERNATING-CURRENT; CRACKING BEHAVIOR; PIPELINE STEEL; CATHODIC PROTECTION; MECHANISTIC ASPECT; CURRENT-DENSITY; CARBON-STEEL; MILD-STEEL; VOLTAGE;
D O I
10.20964/2021.06.08
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
In this work, the corrosion mechanism of X80 steel under AC interference was studied with electrochemical measurements. The surface potential was monitored at various AC current densities. EIS (electrochemical impedance spectroscopy) measurements were conducted at various AC voltage amplitudes and for various time durations. Variations in the modulus values of the real part and imaginary part were studied. In addition, to simplify the problem, EIS was measured under the effect of various DC potentials. The surface potential was of the same frequency as the AC interference, and the amplitude of the electrode surface potential was linear with the applied current density. As the AC current density increased, the charge transfer resistance decreased due to the acceleration of both the anodic and cathodic processes. When the AC current density reached a certain value, hydrogen and oxygen evolution occurred because the effective Faraday potential exceeded the corresponding critical reaction potential. With an increasing AC time, the charge transfer resistance increased, which was due to the formation of a protective corrosion product film. With the application of low-amplitude AC voltages, there was only a small change in the capacitance of the electric double layer. Nevertheless, with the application of AC voltages at higher amplitudes, the modulus values of the real and imaginary parts of EIS were all less rapid, and the ratio of the imaginary part and real part decreased.
引用
收藏
页码:1 / 13
页数:13
相关论文
共 50 条
  • [21] A study on corrosion of X80 steel in a simulated tidal zone
    Zhou, Xiaobao
    Wu, Tangqing
    Tan, Lin
    Deng, Jiahao
    Li, Cong
    Qiu, Wei
    JOURNAL OF MATERIALS RESEARCH AND TECHNOLOGY-JMR&T, 2021, 12 : 2224 - 2237
  • [22] Corrosion Behavior of X80 Pipe Steel under HVDC Interference in Sandy Soil
    Qin, Runzhi
    Du, Yanxia
    Jiang, Zitao
    Wang, Xiuyun
    Fu, Anqing
    Lu, Yi
    METALS, 2018, 8 (10)
  • [23] Effect of alternating current and Bacillus cereus on the stress corrosion behavior and mechanism of X80 steel in a Beijing soil solution
    Wan, Hongxia
    Song, Dongdong
    Du, Cuiwei
    Liu, Zhiyong
    Li, Xiaogang
    BIOELECTROCHEMISTRY, 2019, 127 : 49 - 58
  • [24] Study on hydrogen permeation behavior of X80 steel under AC stray current interference
    Wang, Ailing
    Deng, Yong
    Li, Kaihong
    Li, Wenlei
    Yu, Dongliang
    Cui, Gan
    Liu, JianGuo
    Li, Zili
    ANTI-CORROSION METHODS AND MATERIALS, 2021, 68 (02) : 64 - 76
  • [25] Effect of applied potentials on stress corrosion cracking susceptibility of X80 pipeline steel in simulated soil solution
    Cheng, Yuan
    Yu, Hongying
    Zhang, Lixin
    Wang, Ying
    Meng, Xu
    Sun, Dongbai
    ADVANCES IN SUPERALLOYS, PTS 1 AND 2, 2011, 146-147 : 920 - +
  • [26] Effect of HCO3- Concentration on the Corrosion Behaviour of X80 Pipeline Steel in Simulated Soil Solution
    Xie, Fei
    Wang, Dan
    Yu, Chengxiang
    Zong, Yue
    Wu, Ming
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2017, 12 (10): : 9565 - 9574
  • [27] Corrosion Behavior of X80 Steel with Coupled Coating Defects under Alternating Current Interference in Alkaline Environment
    Li, Zhong
    Li, Caiyu
    Qian, Hongchang
    Li, Jun
    Huang, Liang
    Du, Cuiwei
    MATERIALS, 2017, 10 (07):
  • [28] Effect of CO32- Concentration on the Corrosion Behavior of X80 Pipeline Steel in Simulated Soil Solution
    Zhang, Qiu Li
    Xue, Meng Han
    Wang, Dan
    Zi, Yang
    Zhou, Jun
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2020, 15 (05): : 4592 - 4601
  • [29] Corrosion Behavior of X70 and X80 Pipeline Steels in Simulated Soil Solution
    Wang, Xinhua
    Song, Xuting
    Chen, Yingchun
    Wang, Zuquan
    Zhang, Liuwei
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2018, 13 (07): : 6436 - 6450
  • [30] Corrosion Behavior of Pipeline Steel with Different Microstructures Under AC Interference in Acid Soil Simulation Solution
    Zhu, M.
    Yuan, Y. F.
    Yin, S. M.
    Yu, G. H.
    Guo, S. Y.
    Huang, Y. Z.
    Du, C. W.
    JOURNAL OF MATERIALS ENGINEERING AND PERFORMANCE, 2019, 28 (03) : 1698 - 1706