Construction of a ratiometric fluorescent probe with an extremely large emission shift for imaging hypochlorite in living cells

被引:37
|
作者
Song, Xuezhen [1 ]
Dong, Baoli [1 ]
Kong, Xiuqi [1 ]
Wang, Chao [1 ]
Zhang, Nan [1 ]
Lin, Weiying [1 ]
机构
[1] Univ Jinan, Sch Mat Sci & Engn, Sch Chem & Chem Engn, Inst Fluorescent Probes Biol Imaging, Jinan 250022, Shandong, Peoples R China
关键词
Fluorescent probe; Hypochlorite; Ratiometric fluorescence imaging; HYDROGEN-PEROXIDE; REACTIVE OXYGEN; CANCER-CELLS; OXIDATIVE STRESS; RATIONAL DESIGN; MYELOPEROXIDASE; ACID; SELECTIVITY; DISEASE; SYSTEMS;
D O I
10.1016/j.saa.2017.07.011
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
Hypochlorite is one of the important reactive oxygen species (ROS) and plays,critical roles in many biologically vital processes. Herein, we present a unique ratiometric fluorescent probe (CBP) with an extremely large emission shift for detecting hypochlorite in living cells. Utilizing positively charged alpha,beta-unsaturated carbonyl group as the reaction site, the probe CBP itself exhibited near-infrared (NIR) fluorescence at 662 nm, and can display strong blue fluorescence at 456 nm when responded to hypochlorite. Notably, the extremely large emission shift of 206 nm could enable the precise measurement of the fluorescence peak intensities and ratios. CBP showed high sensitivity, excellent selectivity, desirable performance at physiological pH, and low cytotoxicity. The bioimaging experiments demonstrate the biological application of CBP for the ratiometric imaging of hypo chlorite in living cells. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:394 / 399
页数:6
相关论文
共 50 条
  • [21] A ratiometric fluorescent probe for hydrogen sulfide imaging in living cells
    Jiang, Yin
    Wu, Qiong
    Chang, Xijun
    TALANTA, 2014, 121 : 122 - 126
  • [22] A ratiometric fluorescent probe for selective imaging of methylglyoxal in living cells
    Liang, Zhaolun
    Jiang, Zhiyong
    Zhang, Changli
    Liu, Zhipeng
    JOURNAL OF MOLECULAR STRUCTURE, 2023, 1285
  • [23] A ratiometric fluorescent probe for imaging hydroxyl radicals in living cells
    Soh, N
    Makihara, K
    Sakoda, E
    Imato, T
    CHEMICAL COMMUNICATIONS, 2004, (05) : 496 - 497
  • [24] A novel fluorescent probe with red emission and a large Stokes shift for selective imaging of endogenous cysteine in living cells
    Chen, Dugang
    Long, Zi
    Dang, Yecheng
    Chen, Li
    ANALYST, 2018, 143 (23) : 5779 - 5784
  • [25] Development of an ICT-based ratiometric fluorescent hypochlorite probe suitable for living cell imaging
    Yuan, Lin
    Lin, Weiying
    Song, Jizeng
    Yang, Yueting
    CHEMICAL COMMUNICATIONS, 2011, 47 (47) : 12691 - 12693
  • [26] A fluorescent probe for hypochlorite with colorimetric and fluorometric characteristics and imaging in living cells
    Hu, Cunjie
    Li, Jianping
    Yan, Liqiang
    ANALYTICAL BIOCHEMISTRY, 2019, 566 : 32 - 36
  • [27] Dicyanoisophorone-based fluorescent probe with large Stokes shift for ratiometric detection and imaging of exogenous/endogenous hypochlorite in cell and zebrafish
    Kong, Xiang-yu
    Shuang, Shao-Min
    Zhang, Yue-tao
    Wang, Yu
    Dong, Chuan
    Talanta, 2022, 242
  • [28] Dicyanoisophorone-based fluorescent probe with large Stokes shift for ratiometric detection and imaging of exogenous/endogenous hypochlorite in cell and zebrafish
    Kong, Xiang-yu
    Shuang, Shao-Min
    Zhang, Yue-tao
    Wang, Yu
    Dong, Chuan
    TALANTA, 2022, 242
  • [29] A novel ratiometric fluorescent probe for the detection and imaging of cysteine in living cells
    Zheng, Cheng
    Zhou, Xiaoqin
    Wang, Huizhe
    Ji, Min
    Wang, Peng
    BIOORGANIC CHEMISTRY, 2022, 127
  • [30] A ratiometric near-infrared fluorescent probe with a large emission peak shift for sensing and imaging hypochlorous acid
    He, Meng
    Ye, Miantai
    Wang, Zhengguo
    Liu, Pan
    Li, Huiyue
    Lu, Chunfeng
    Wang, Yanying
    Liang, Tao
    Li, Haiyan
    Li, Chunya
    SENSORS AND ACTUATORS B-CHEMICAL, 2021, 343