Construction of a ratiometric fluorescent probe with an extremely large emission shift for imaging hypochlorite in living cells

被引:37
|
作者
Song, Xuezhen [1 ]
Dong, Baoli [1 ]
Kong, Xiuqi [1 ]
Wang, Chao [1 ]
Zhang, Nan [1 ]
Lin, Weiying [1 ]
机构
[1] Univ Jinan, Sch Mat Sci & Engn, Sch Chem & Chem Engn, Inst Fluorescent Probes Biol Imaging, Jinan 250022, Shandong, Peoples R China
关键词
Fluorescent probe; Hypochlorite; Ratiometric fluorescence imaging; HYDROGEN-PEROXIDE; REACTIVE OXYGEN; CANCER-CELLS; OXIDATIVE STRESS; RATIONAL DESIGN; MYELOPEROXIDASE; ACID; SELECTIVITY; DISEASE; SYSTEMS;
D O I
10.1016/j.saa.2017.07.011
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
Hypochlorite is one of the important reactive oxygen species (ROS) and plays,critical roles in many biologically vital processes. Herein, we present a unique ratiometric fluorescent probe (CBP) with an extremely large emission shift for detecting hypochlorite in living cells. Utilizing positively charged alpha,beta-unsaturated carbonyl group as the reaction site, the probe CBP itself exhibited near-infrared (NIR) fluorescence at 662 nm, and can display strong blue fluorescence at 456 nm when responded to hypochlorite. Notably, the extremely large emission shift of 206 nm could enable the precise measurement of the fluorescence peak intensities and ratios. CBP showed high sensitivity, excellent selectivity, desirable performance at physiological pH, and low cytotoxicity. The bioimaging experiments demonstrate the biological application of CBP for the ratiometric imaging of hypo chlorite in living cells. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:394 / 399
页数:6
相关论文
共 50 条
  • [1] A highly sensitive ratiometric fluorescent probe with a large emission shift for imaging endogenous cysteine in living cells
    Zhu, Baocun
    Guo, Bingpeng
    Zhao, Yunzhou
    Zhang, Bing
    Du, Bin
    BIOSENSORS & BIOELECTRONICS, 2014, 55 : 72 - 75
  • [2] A ratiometric fluorescent probe with large Stokes shift and emission shift for sensing hydrazine in living organisms
    Su, Hang
    Wang, Jingpei
    Yue, Xiuxiu
    Wang, Benhua
    Song, Xiangzhi
    Spectrochimica Acta - Part A: Molecular and Biomolecular Spectroscopy, 2022, 274
  • [3] A ratiometric fluorescent probe with large Stokes shift and emission shift for sensing hydrazine in living organisms
    Su, Hang
    Wang, Jingpei
    Yue, Xiuxiu
    Wang, Benhua
    Song, Xiangzhi
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2022, 274
  • [4] A red-emitting ratiometric fluorescent probe with large Stokes shift and emission peak shift for imaging hypochlorous acid in living cells and zebrafish
    Zhang, Yan
    Yang, Haiyan
    Li, Mingxin
    Gong, Shuai
    Song, Jie
    Wang, Zhonglong
    Wang, Shifa
    DYES AND PIGMENTS, 2022, 197
  • [5] Development of a ratiometric fluorescent probe with a large emission shift for imaging ONOO- in live cells and zebrafish
    Jia, Pan
    Zhuang, Zihan
    Liu, Caiyun
    Wang, Zuokai
    Duan, Qingxia
    Li, Zilu
    Zhu, Hanchuang
    Zhang, Fenfen
    Sheng, Wenlong
    Zhu, Baocun
    DYES AND PIGMENTS, 2020, 173
  • [6] A ratiometric fluorescent probe for rapid and sensitive visualization of hypochlorite in living cells
    Zha, Jiayu
    Fu, Boqiao
    Qin, Caiqin
    Zeng, Lintao
    Hu, Xichao
    RSC ADVANCES, 2014, 4 (81): : 43110 - 43113
  • [7] A mitochondria-targeted colorimetric and ratiometric fluorescent probe for hydrogen peroxide with a large emission shift and bio-imaging in living cells
    Shen, Youming
    Zhang, Xiangyang
    Zhang, Youyu
    Wu, Yanyang
    Zhang, Chunxiang
    Chen, Yuandao
    Jin, Junling
    Li, Haitao
    SENSORS AND ACTUATORS B-CHEMICAL, 2018, 255 : 42 - 48
  • [8] Ratiometric Emission Fluorescent pH Probe for Imaging of Living Cells in Extreme Acidity
    Niu, Weifen
    Fan, Li
    Nan, Ming
    Li, Zengbo
    Lu, Dongtao
    Wong, Man Shing
    Shuang, Shaomin
    Dong, Chuan
    ANALYTICAL CHEMISTRY, 2015, 87 (05) : 2788 - 2793
  • [9] A colorimetric and ratiometric fluorescent probe for Cu2+ with a large red shift and its imaging in living cells
    Chen, Song
    Hou, Peng
    Foley, James W.
    Song, Xiangzhi
    RSC ADVANCES, 2013, 3 (16) : 5591 - 5596
  • [10] A ratiometric fluorescent probe with an extremely large emission shift for detecting ClO- and its application in test strips and cell imaging
    Xu, Xiaohang
    Ding, Haichang
    Zhang, Qian
    Liu, Gang
    Pu, Shouzhi
    DYES AND PIGMENTS, 2022, 207