Magneto-actuated immunoassay for the detection of Mycobacterium fortuitum in hemodialysis water

被引:10
作者
Brugnera, Michelle Fernanda [1 ,3 ]
Bundalian, Reynaldo, Jr. [1 ,4 ]
Laube, Tamara [1 ]
Julian, Esther [2 ]
Luquin, Marina [2 ]
Boldrin Zanoni, Maria Valnice [3 ]
Pividori, Maria Isabel [1 ]
机构
[1] Univ Autonoma Barcelona, Dept Quim, Grp Sensors & Biosensors, Bellaterra, Spain
[2] Univ Autonoma Barcelona, Fac Biociencies, Dept Genet & Microbiol, Bellaterra, Spain
[3] UNESP Univ Estadual Paulista, Inst Chem, Dept Analyt Chem, Araraquara, SP, Brazil
[4] Angeles Univ Fdn, Coll Arts & Sci, Dept Chem, Angeles City, Philippines
基金
巴西圣保罗研究基金会;
关键词
Magneto-actuated immunoassay; Immunomagnetic separation; Mycobacterium fortuitum; Hemodialysis water; FLUIDS; ASSAY;
D O I
10.1016/j.talanta.2016.02.041
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This paper addresses a sensitive method for the detection of mycobacteria in hemodialysis water samples based on a magneto-actuated immunoassay with optical readout. In this approach, micro (2.8 mu m) sized magnetic particles were modified with an antibody against the lipoarabinomannan (LAM) located in the mycobacterial cell wall. The system relies on the immunocapturing of the mycobacteria with the tailored antiLAM magnetic particles to pre-concentrate the bacteria from the hemodialysis samples throughout an immunological reaction. The performance of the immunomagnetic separation on the magnetic carrier was evaluated using confocal microscopy to study the binding pattern, as well as a magneto-actuated immunoassay with optical readout for the rapid detection of the bacteria in spiked hemodialysis samples. In this approach, the antiLAM polyclonal antibody was labeled with fluorescein isothiocyanate. The optical readout was achieved by the incubation with a secondary anti-fluorescein antibody labeled with peroxidase as optical reporter. The magneto-actuated immunoassay was able to detect mycobacteria contamination in hemodialysis water at a limit of detection of 13 CFU mL(-1) in a total assay time of 3 h without any previous culturing pre-enrichment step. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:38 / 44
页数:7
相关论文
共 15 条
[1]   COMPARISON OF MICROBIOLOGIC ASSAY-METHODS FOR HEMODIALYSIS FLUIDS [J].
ARDUINO, MJ ;
BLAND, LA ;
AGUERO, SM ;
CARSON, L ;
RIDGEWAY, M ;
FAVERO, MS .
JOURNAL OF CLINICAL MICROBIOLOGY, 1991, 29 (03) :592-594
[2]   Immunomagnetic separation of Salmonella with tailored magnetic micro and nanocarriers. A comparative study [J].
Brandao, Delfina ;
Liebana, Susana ;
Campoy, Susana ;
Alegret, Salvador ;
Isabel Pividori, Maria .
TALANTA, 2015, 143 :198-204
[3]   Biofilm development by potentially pathogenic non-pigmented rapidly growing mycobacteria [J].
Esteban, Jaime ;
Martin-de-Hijas, Nieves Z. ;
Kinnari, Teemu J. ;
Ayala, Guillermo ;
Fernandez-Roblas, Ricardo ;
Gadea, Ignacio .
BMC MICROBIOLOGY, 2008, 8 (1)
[4]  
Hall-Stoodley L, 1998, FEMS MICROBIOL LETT, V168, P77, DOI 10.1111/j.1574-6968.1998.tb13258.x
[5]   Essential Components of an Infection Prevention Program for Outpatient Hemodialysis Centers [J].
Hess, Sally ;
Bren, Virginia .
SEMINARS IN DIALYSIS, 2013, 26 (04) :384-398
[6]   Rapid monitoring of CFP-10 during culture of Mycobacterium tuberculosis by using a magnetophoretic immunoassay [J].
Kim, Jeonghyo ;
Lee, Jaewook ;
Lee, Kang-In ;
Park, Tae Jung ;
Kim, Hwa-Jung ;
Lee, Jaebeom .
SENSORS AND ACTUATORS B-CHEMICAL, 2013, 177 :327-333
[7]   Mycobacterium chelonae peritonitis in peritoneal dialysis. Literature review [J].
Kunin, M. ;
Knecht, A. ;
Holtzman, E. J. .
EUROPEAN JOURNAL OF CLINICAL MICROBIOLOGY & INFECTIOUS DISEASES, 2014, 33 (08) :1267-1271
[8]   Rapid detection of Salmonella in milk by electrochemical magneto-immunosensing [J].
Liebana, Susana ;
Lermo, Anabel ;
Campoy, Susana ;
Pilar Cortes, Maria ;
Alegret, Salvador ;
Isabel Pividori, Maria .
BIOSENSORS & BIOELECTRONICS, 2009, 25 (02) :510-513
[9]   Rapid detection of influenza A virus infection utilizing an immunomagnetic bead-based microfluidic system [J].
Lien, Kang-Yi ;
Hung, Lien-Yu ;
Huang, Tze-Bin ;
Tsai, Yi-Che ;
Lei, Huan-Yao ;
Lee, Gwo-Bin .
BIOSENSORS & BIOELECTRONICS, 2011, 26 (09) :3900-3907
[10]  
Martin J.M., 1996, THESE INCLUDE MONOCL