Assessing dynamic change in muscle during treatment of patients with cancer: Precision testing standards

被引:15
作者
Arribas, Lorena [1 ,2 ,3 ,4 ]
Sabate-Llobera, Aida [2 ,5 ]
Cos Domingo, Monica [3 ,6 ]
Taberna, Miren [2 ,3 ,7 ]
Sospedra, Maria [8 ]
Martin, Lisa [9 ]
Regina Gonzalez-Tampan, Ana [1 ,3 ]
Pallares, Natalia [10 ]
Mesia, Ricard [2 ,3 ,11 ]
Baracos, Vickie E. [9 ]
机构
[1] Catalan Inst Oncol ICO, Clin Nutr Unit, Gran Via Hosp 199-203, Barcelona 08908, Spain
[2] Bellvitge Biomed Res Inst IDIBELL, Barcelona, Spain
[3] Bellvitge Univ Hosp, Head & Neck Canc Unit, Catalan Inst Oncol ICO, Barcelona, Spain
[4] Univ Barcelona, Barcelona, Spain
[5] Bellvitge Univ Hosp, PET Unit IDI, Dept Nucl Med, Barcelona, Spain
[6] IDI Bellvitge Univ Hosp, Dept Neuroradiol, Barcelona, Spain
[7] ONCOBELL, Med Oncol Dept, Catalan Inst Oncol ICO, Barcelona, Spain
[8] Hosp Univ Germans Trias I Pujol HUGTIP, Unitat Nutr Clin Dietet 1, Barcelona, Spain
[9] Univ Alberta, Dept Oncol, Div Palliat Care Med, Edmonton, AB, Canada
[10] Bellvitge Univ Hosp, Unitat Bioestadist UBiDi, Barcelona, Spain
[11] Catalan Inst Oncol ICO Badalona, Med Oncol Dept, B ARGO Grp, Barcelona, Spain
关键词
Precision test; Least significant change; Squamous cell carcinoma of the head and neck; Body composition; Muscle wasting; Positron emission tomography-computed tomography (PET/CT); X-RAY ABSORPTIOMETRY; SKELETAL-MUSCLE; INTERNATIONAL SOCIETY; OFFICIAL POSITIONS; BODY-COMPOSITION; ADIPOSE-TISSUE; NECK-CANCER; GUIDELINES; CACHEXIA; HEAD;
D O I
10.1016/j.clnu.2022.03.016
中图分类号
R15 [营养卫生、食品卫生]; TS201 [基础科学];
学科分类号
100403 ;
摘要
Background: Computed tomography images acquired during routine cancer care provide an opportunity to determine body composition with accuracy and precision. Quantification of skeletal muscle is of interest owing to its association with clinical outcomes. However, the standards of precision testing considered mandatory in other areas of radiology are lacking from the literature in this area. We aim to describe the change in skeletal muscle over time at different anatomical levels using the precision error. Methods: Thirty-eight male patients with squamous cell carcinoma of the head and neck were evaluated at two time points encompassing their treatment plan. Precision testing consisted of analyzing the crosssectional area (CSA) of the skeletal muscle and total adipose tissue of 76 CT studies (38 images at baseline repeated twice and 38 follow-up images repeated twice) measured by a skilled observer. The % coeffi-cient of variation (%CV), the root-mean-square standard deviation (RMS SD) and the corresponding 95% least significant change (LSC) were calculated for four anatomical levels: upper arm, thigh, chest and abdomen. Results: The median time between scans was 223.6 (SD 31.2) days. Precision error (% CV) for total skeletal muscle cross sectional area was 0.86% for upper arm, 0.26% for thigh, 0.39% for chest and 0.63% for abdomen. The corresponding LSC values in upper arm, thigh, chest and abdomen were 2.4%, 0.7%, 1.1% and 1.8%, respectively. Based on the LSC for RMS SD, patients were classified in two categories according to muscle crosssectional area: stable (i.e within LSC value) or gained and loss. To compare the four anatomical levels, the proportion of patients with muscle loss exceeding the LSC value was 74.3% for arm, 86.2% for thigh, 82.9% for chest and 76.3% for abdomen. For these same anatomic regions, the mean muscle loss for those patients classified below the LSC was 14.6% (SD 9.3), 13.4% (SD 7.8), 11.9% (SD 6.5) and 11.6% (SD 5.5), respectively. Only the loss of muscle area was significantly higher in thigh (p = 0.023), using L3 as the reference level. Conclusions: We recommend the uniform use of a standard precision test when reporting muscle change over time. LSC values vary from 0.7 to 2.4% depending on anatomic site; with the lowest precision error to detect change in the thigh. Based on this analysis, muscle wasting appears to be systemic and while present in limbs and trunk is significantly higher in the thigh than in the chest, abdomen or upper arm. (C) 2022 Elsevier Ltd and European Society for Clinical Nutrition and Metabolism. All rights reserved.
引用
收藏
页码:1059 / 1065
页数:7
相关论文
共 39 条
[1]   Nutritional changes in patients with locally advanced head and neck cancer during treatment [J].
Arribas, L. ;
Hurtos, L. ;
Taberna, M. ;
Peiro, I. ;
Vilajosana, E. ;
Lozano, A. ;
Vazquez, S. ;
Mesia, R. ;
Virgili, N. .
ORAL ONCOLOGY, 2017, 71 :67-74
[2]   Adequacy of nutritional support using computed tomography (CT) in patients with head and neck cancer (HNC) during chemo-radiotherapy (CRT) [J].
Arribas, Lorena ;
Sabate-Llobera, Aida ;
Taberna, Miren ;
Pallares, Natalia ;
Marin, Alicia Narro ;
Virgili, Nuria ;
Hurtos, Laura ;
Peiro, Inmaculada ;
Vilajosana, Esther ;
Lozano, Alicia ;
Baracos, Vickie ;
Mesia, Ricard .
EUROPEAN JOURNAL OF CLINICAL NUTRITION, 2021, 75 (10) :1515-1519
[3]   Precision assessment and radiation safety for dual-energy X-ray absorptiometry [J].
Baim, S ;
Wilson, CR ;
Lewiecki, EM ;
Luckey, MM ;
Downs, RW ;
Lentle, BC .
JOURNAL OF CLINICAL DENSITOMETRY, 2005, 8 (04) :371-378
[4]   Cancer cachexia is defined by an ongoing loss of skeletal muscle mass [J].
Baracos, Vickie E. ;
Mazurak, Vera C. ;
Bhullar, Amritpal S. .
ANNALS OF PALLIATIVE MEDICINE, 2019, 8 (01) :3-12
[5]   Cancer-associated cachexia [J].
Baracos, Vickie E. ;
Martin, Lisa ;
Korc, Murray ;
Guttridge, Denis C. ;
Fearon, Kenneth C. H. .
NATURE REVIEWS DISEASE PRIMERS, 2018, 4
[6]   FDG PET/CT: EANM procedure guidelines for tumour imaging: version 2.0 [J].
Boellaard, Ronald ;
Delgado-Bolton, Roberto ;
Oyen, Wim J. G. ;
Giammarile, Francesco ;
Tatsch, Klaus ;
Eschner, Wolfgang ;
Verzijlbergen, Fred J. ;
Barrington, Sally F. ;
Pike, Lucy C. ;
Weber, Wolfgang A. ;
Stroobants, Sigrid ;
Delbeke, Dominique ;
Donohoe, Kevin J. ;
Holbrook, Scott ;
Graham, Michael M. ;
Testanera, Giorgio ;
Hoekstra, Otto S. ;
Zijlstra, Josee ;
Visser, Eric ;
Hoekstra, Corneline J. ;
Pruim, Jan ;
Willemsen, Antoon ;
Arends, Bertjan ;
Kotzerke, Joerg ;
Bockisch, Andreas ;
Beyer, Thomas ;
Chiti, Arturo ;
Krause, Bernd J. .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2015, 42 (02) :328-354
[7]   Importance of precision in bone density measurements [J].
Bonnick, SL ;
Johnston, CC ;
Kleerekoper, M ;
Lindsay, R ;
Miller, P ;
Sherwood, L ;
Siris, E .
JOURNAL OF CLINICAL DENSITOMETRY, 2001, 4 (02) :105-110
[8]   Effect of Chemotherapy on Dual-Energy X-ray Absorptiometry (DXA) Body Composition Precision Error in Head and Neck Cancer Patients [J].
Chang, Ho-Chuen ;
Lin, Yu-Ching ;
Ng, Shu-Hang ;
Cheung, Yun-Chung ;
Wang, Cheng-Hsu ;
Chen, Fang-Ping ;
Chang, Hui-Ping ;
Sung, Chen-Ming ;
Fan, Chih-Ming ;
Yeh, Kun-Yun ;
Wu, Jim S. .
JOURNAL OF CLINICAL DENSITOMETRY, 2019, 22 (03) :437-443
[9]   Patterns, Predictors, and Prognostic Value of Skeletal Muscle Mass Loss in Patients with Locally Advanced Head and Neck Cancer Undergoing Cisplatin-Based Chemoradiotherapy [J].
Chargi, Najiba ;
Wegner, Inge ;
Markazi, Navid ;
Smid, Ernst ;
de Jong, Pim ;
Devriese, Lot ;
de Bree, Remco .
JOURNAL OF CLINICAL MEDICINE, 2021, 10 (08)
[10]   Precision of the Hologic Horizon A dual energy X-ray absorptiometry in the assessment of body composition [J].
Cheung, Y. M. ;
Roff, G. ;
Grossmann, M. .
OBESITY RESEARCH & CLINICAL PRACTICE, 2020, 14 (06) :514-518