Bedside monitoring of subcutaneous interstitial glucose in healthy individuals using microdialysis and infrared spectrometry

被引:26
作者
Heise, H. Michael
Damm, Uwe
Bodenlenz, Manfred
Kondepati, Venkata Radhakrishna
Koehler, Gerd
Ellmerer, Martin
机构
[1] Univ Dortmund, Inst Analyt Sci, D-44139 Dortmund, Germany
[2] Jaonneum Res Forschungsgesellsch GmbH, Inst Med Technol & Hlth Management, A-8010 Graz, Austria
[3] Med Univ Graz, Dept Internal Med, Div Diabet & Metab, A-8036 Graz, Austria
关键词
infrared spectroscopy; microdialysis; blood glucose analysis; continuous monitoring; interstitial fluid;
D O I
10.1117/1.2714907
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
An IR-spectroscopy-based bedside device, coupled to a subcutaneously implanted microdialysis probe, is developed for quasicontinuous glucose monitoring with intermittent readouts at 10-min intervals, avoiding any sensor recalibration under long-term operation. The simultaneous estimation of the microdialysis recovery rate is possible using an acetate containing perfusate and determining its losses across the dialysis membrane. Measurements are carried out on four subjects, with experiments lasting either 8 or 28 h, respectively. Using the spectral interval data either from 1180 to 950 or 1560 to 1000 cm(-1), standard errors of prediction (SEPs) between 0.13 and 0.28 mM are achieved using multivariate calibration with partial least-squares (PLS) or classical least-squares (CLS) calibration models, respectively. The transfer of a PLS calibration model using the spectral and reference concentration data of the dialysates from the three 8-h-long experiments to a 28-h monitoring episode with another healthy subject is tested. Including microdialysis recovery for the determination of the interstitial glucose concentrations, an SEP of 0.24 mM is obtained versus whole blood glucose values. The option to determine other metabolites such as urea or lactate offers the possibility to develop a calibration- and reagent-free point-of-care analyzer. (C) 2007 Society of Photo-Optical Instrumentation Engineers.
引用
收藏
页数:12
相关论文
共 40 条
[21]   Determination of glucose in whole blood samples by mid-infrared spectroscopy [J].
Kim, YJ ;
Hahn, S ;
Yoon, G .
APPLIED OPTICS, 2003, 42 (04) :745-749
[22]   Infrared transmission spectrometry for the determination of urea in microliter sample volumes of blood plasma dialysates [J].
Kondepati, Venkata Radhakrishna ;
Damm, Uwe ;
Heise, H. Michael .
APPLIED SPECTROSCOPY, 2006, 60 (08) :920-925
[23]   Continuous glucose monitoring by means of fiber-based, mid-infrared laser spectroscopy [J].
Lambrecht, A. ;
Beyer, T. ;
Hebestreit, K. ;
Mischler, R. ;
Petrich, W. .
APPLIED SPECTROSCOPY, 2006, 60 (07) :729-736
[24]  
LENTNER C, 1979, WISSENSCHAFTLICHE TA
[25]   Middle infrared, quantum cascade laser optoelectronic absorption system for monitoring glucose in serum [J].
Martin, WB ;
Mirov, S ;
Venugopalan, R .
APPLIED SPECTROSCOPY, 2005, 59 (07) :881-884
[26]   Using two discrete frequencies within the middle infrared to quantitatively determine glucose in serum [J].
Martin, WB ;
Mirov, S ;
Venugopalan, R .
JOURNAL OF BIOMEDICAL OPTICS, 2002, 7 (04) :613-617
[27]   Acetazolamide-mediated decrease in strong ion difference accounts for the correction of metabolic alkalosis in critically ill patients [J].
Moviat, Miriam ;
Pickkers, Peter ;
van der Voort, Peter H. J. ;
van der Hoeven, Johannes G. .
CRITICAL CARE, 2006, 10 (01)
[28]   Tunable laser diode system for noninvasive blood glucose measurements [J].
Olesberg, JT ;
Arnold, MA ;
Mermelstein, C ;
Schmitz, J ;
Wagner, J .
APPLIED SPECTROSCOPY, 2005, 59 (12) :1480-1484
[29]  
OMRON E, 2005, J INTENSIVE CARE MED, V20, P269
[30]   Comparison of mid-infrared and Raman spectroscopy in the quantitative analysis of serum -: art. no. 031108 [J].
Rohleder, D ;
Kocherscheidt, G ;
Gerber, K ;
Kiefer, W ;
Köhler, W ;
Möcks, J ;
Petrich, W .
JOURNAL OF BIOMEDICAL OPTICS, 2005, 10 (03)