The determination of glutamine with flow-injection chemiluminescence detection and mechanism study

被引:7
作者
Liu, Yan-Ming [1 ]
Liu, Zhuan-Li [1 ]
Shi, Yan-Mei [1 ]
Tian, Wei [1 ]
机构
[1] Xinyang Normal Univ, Coll Chem & Chem Engn, Xinyang 464000, Peoples R China
基金
中国国家自然科学基金;
关键词
glutamine; chemiluminescence; flow-injection; mechanism study; AMINO-ACIDS; CAPILLARY-ELECTROPHORESIS; LUMINOL; NUTRITION; FLUIDS; MEDIA; ASSAY;
D O I
10.1002/bio.1143
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The main purpose of this study was to develop an inexpensive, simple, rapid and sensitive chemiluminescence (CL) method for the determination of glutamine (Gln) using a flow-injection (FI) system. Gin was found to strongly inhibit the CL signal of the luminol-H2O2-CuSO4 system in Na2B4O7 solution. A new FI-CL method was developed for the determination of Gin. Parameters affecting the reproducibility and CL detection were optimized systematically. Under the optimized conditions, the corresponding linear regression equation was established over the range of 5.0 x 10(-7) to 2.5 x 10(-6) mol/L with the detection limit of 1.8 x 10(-8) mol/L. The relative standard deviation was found to be 1.8% for 11 replicate determinations of 1.5 x 10(-6) mol/L Gln. The proposed method has been satisfactorily applied for the determination of Gln in real samples (Marzulene-s granules) with recoveries in the range of 98.7-108.6%. The minimum sampling rate was about 100 samples/h. The possible mechanism of this inhibitory CL was studied by fluorescence spectrophotometer and UV-vis spectrophotometer. Copyright (C) 2009 John Wiley & Sons, Ltd.
引用
收藏
页码:50 / 54
页数:5
相关论文
共 33 条
[1]  
Afanas'ev I.B., 1989, SUPEROXIDE ION CHEM, V1
[2]   The determination of levofloxacin by flow injection analysis using UV detection, potentiometry, and conductometry in pharmaceutical preparations [J].
Altiokka, G ;
Atkosar, Z ;
Can, NO .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2002, 30 (03) :881-885
[3]   Glutamine alimentation in catabolic state [J].
Boelens, PG ;
Nijveldt, RJ ;
Houdijk, APJ ;
Meijer, S ;
van Leeuwen, PAM .
JOURNAL OF NUTRITION, 2001, 131 (09) :2569S-2577S
[4]   Real-time monitoring of picomolar concentrations of iron(II) in marine waters using automated flow injection-chemiluminescence instrumentation [J].
Bowie, AR ;
Achterberg, EP ;
Sedwick, PN ;
Ussher, S ;
Worsfold, PJ .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2002, 36 (21) :4600-4607
[5]   NUTRITION NEEDS OF MAMMALIAN CELLS IN TISSUE CULTURE [J].
EAGLE, H .
SCIENCE, 1955, 122 (3168) :501-504
[6]  
[方卢秋 FANG Luqiu], 2006, [四川师范大学学报. 自然科学版, Journal of Sichuan Normal University. Natural Science Edition], V29, P333
[7]   Automated flow injection analyzer with on-line solid-phase extraction and chemiluminescence detection for the determination of dodecylamine in diesel fuels [J].
Fletcher, PJ ;
Andrew, KN ;
Forbes, S ;
Worsfold, PJ .
ANALYTICAL CHEMISTRY, 2003, 75 (11) :2618-2625
[8]   Electrogenerated chemiluminescence of CdSe quantum dots dispersed in aqueous solution [J].
Han, Heyou ;
You, Zihan ;
Liang, Jiangong ;
Sheng, Zonghai .
FRONTIERS IN BIOSCIENCE-LANDMARK, 2007, 12 :2352-U131
[9]  
HAUAOKA S, 2000, ANAL CHIM ACTA, V409, P65
[10]   Rapid Determination of l-Glutamine using Engineered Escherichia coli Overexpressing Glutamine Synthetase [J].
Hong, Ni-Ning ;
Yang, Guang ;
Li, Jian ;
Zhang, Yao-Ping ;
Li, Ji-Lun .
APPLIED BIOCHEMISTRY AND BIOTECHNOLOGY, 2009, 158 (02) :398-407