Cuff-Less Blood Pressure Estimation Using Pulse Waveform Analysis and Pulse Arrival Time

被引:65
作者
Yoon, Young-Zoon [1 ]
Kang, Jae Min [1 ]
Kwon, Yongjoo [1 ]
Park, Sangyun [1 ]
Noh, Seungwoo [1 ]
Kim, Younho [1 ]
Park, Jongae [1 ]
Hwang, Sung Woo [1 ]
机构
[1] Samsung Adv Inst Technol, Suwon 16678, South Korea
关键词
Cuff-less blood pressure measurement; photoplethysmography; pulse arrival time; pulse waveform analysis; wearable device; TRANSIT-TIME; NONINVASIVE ESTIMATION; VELOCITY; EXERCISE; SIGNALS; MARKER; ECG; PPG;
D O I
10.1109/JBHI.2017.2714674
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Using the massive MIMIC physiological data base, we tried to validate pulse wave analysis (PWA) based on multiparameters model whether it can continuously estimate blood pressure (BP) values on single site of one hand. In addition, to consider the limitation of insufficient data acquirement for home user, we used pulse arrival time (PAT) driven BP information to determine the individual scale factors of the PWA-BP estimation model. Experimental results indicate that the accuracy of the average regression model has error standard deviations of 10.6 +/- 3.3 mmHg (PAT), 8.7 +/- 3.2 mmHg (PWA) for SBP and 6.0 +/- 2.3 mmHg (PAT), 4.4 +/- 1.6 mmHg (PWA) for DBP on 23 subjects over a 1 day period. We defined a local-model which is extracted regression model from sparsely selected small dataset, contrast to full dataset for 24h (average-model). The limit of BP estimation accuracy from the local-model of PWA is lower than that of PAT-BP average-model. Whereas the error of the BP estimation local-model was reduced using more data for scaling, it required more than four times the 1 min data extracted over the 12 h calibration period to predict BP for 1 day. This study shows that PWA has possibility to estimate BP value and PAT-driven BP information could be used to determine the individual scale factors of the PWA-BP estimation model for home users.
引用
收藏
页码:1068 / 1074
页数:7
相关论文
共 22 条
[1]  
[Anonymous], 2002, ANSI AAMI SP, V10
[2]  
Cattivelli FS, 2009, SIXTH INTERNATIONAL WORKSHOP ON WEARABLE AND IMPLANTABLE BODY SENSOR NETWORKS, PROCEEDINGS, P114, DOI [10.1109/BSN.2009.35, 10.1109/P3644.34]
[3]  
Chen Y, 2010, I C CONT AUTOMAT ROB, P1018, DOI 10.1109/ICARCV.2010.5707813
[4]   Continuous Blood Pressure Measurement From Invasive to Unobtrusive: Celebration of 200th Birth Anniversary of Carl Ludwig [J].
Ding, Xiao-Rong ;
Zhao, Ni ;
Yang, Guang-Zhong ;
Pettigrew, Roderic I. ;
Lo, Benny ;
Miao, Fen ;
Li, Ye ;
Liu, Jing ;
Zhang, Yuan-Ting .
IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS, 2016, 20 (06) :1455-1465
[5]   PhysioBank, PhysioToolkit, and PhysioNet - Components of a new research resource for complex physiologic signals [J].
Goldberger, AL ;
Amaral, LAN ;
Glass, L ;
Hausdorff, JM ;
Ivanov, PC ;
Mark, RG ;
Mietus, JE ;
Moody, GB ;
Peng, CK ;
Stanley, HE .
CIRCULATION, 2000, 101 (23) :E215-E220
[6]   Evaluation of Noninvasive Methods to Assess Wave Reflection and Pulse Transit Time From the Pressure Waveform Alone [J].
Kips, Jan G. ;
Rietzschel, Ernst R. ;
De Buyzere, Marc L. ;
Westerhof, Berend E. ;
Gillebert, Thierry C. ;
Van Bortel, Luc M. ;
Segers, Patrick .
HYPERTENSION, 2009, 53 (02) :142-U77
[7]  
Kurylyak Y, 2013, IEEE IMTC P, P280
[8]   Attenuation of Systolic Blood Pressure and Pulse Transit Time Hysteresis During Exercise and Recovery in Cardiovascular Patients [J].
Liu, Qing ;
Yan, Bryan P. ;
Yu, Cheuk-Man ;
Zhang, Yuan-Ting ;
Poon, Carmen C. Y. .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2014, 61 (02) :346-352
[9]   Weighing Scale-Based Pulse Transit Time is a Superior Marker of Blood Pressure than Conventional Pulse Arrival Time [J].
Martin, Stephanie L. -O. ;
Carek, Andrew M. ;
Kim, Chang-Sei ;
Ashouri, Hazar ;
Inan, Omer T. ;
Hahn, Jin-Oh ;
Mukkamala, Ramakrishna .
SCIENTIFIC REPORTS, 2016, 6
[10]   Determinants of pulse wave velocity in healthy people and in the presence of cardiovascular risk factors: 'establishing normal and reference values' [J].
Mattace-Raso, Francesco U. S. ;
Hofman, Albert ;
Verwoert, Germaine C. ;
Witteman, Jacqueline C. M. ;
Wilkinson, Ian ;
Cockcroft, John ;
McEniery, Carmel ;
Yasmin ;
Laurent, Stephane ;
Boutouyrie, Pierre ;
Bozec, Erwan ;
Hansen, Tine Willum ;
Torp-Pedersen, Christian ;
Ibsen, Hans ;
Jeppesen, Jorgen ;
Vermeersch, Sebastian J. ;
Rietzschel, Ernst ;
De Buyzere, Marc ;
Gillebert, Thierry C. ;
Van Bortel, Luc ;
Segers, Patrick ;
Vlachopoulos, Charalambos ;
Aznaouridis, Constantinos ;
Stefanadis, Christodoulos ;
Benetos, Athanase ;
Labat, Carlos ;
Lacolley, Patrick ;
Stehouwer, Coen D. A. ;
Nijpels, Giel ;
Dekker, Jacqueline M. ;
Ferreira, Isabel ;
Twisk, Jos W. R. ;
Czernichow, Sebastien ;
Galan, Pilar ;
Hercberg, Serge ;
Pannier, Bruno ;
Guerin, Alain ;
London, Gerard ;
Cruickshank, J. Kennedy ;
Anderson, Simon G. ;
Paini, Anna ;
Rosei, Enrico Agabiti ;
Muiesan, Maria Lorenza ;
Salvetti, Massimo ;
Filipovsky, Jan ;
Seidlerova, Jitka ;
Dolejsova, Milena .
EUROPEAN HEART JOURNAL, 2010, 31 (19) :2338-2350