An Association Between ICP-Derived Data and Outcome in TBI Patients: The Role of Sample Size

被引:25
作者
Cabella, Brenno [1 ]
Donnelly, Joseph [1 ]
Cardim, Danilo [1 ]
Liu, Xiuyun [1 ]
Cabeleira, Manuel [1 ]
Smielewski, Peter [1 ]
Haubrich, Christina [1 ]
Hutchinson, Peter J. A. [1 ]
Kim, Dong-Joo [1 ,2 ]
Czosnyka, Marek [1 ]
机构
[1] Univ Cambridge, Div Neurosurg, Dept Clin Neurosci, Cambridge, England
[2] Korea Univ, Dept Brain & Cognit Engn, Seoul, South Korea
基金
美国国家卫生研究院;
关键词
Traumatic brain injury; Outcome prediction; Statistical inference; Intracranial pressure; Autoregulation; TRAUMATIC BRAIN-INJURY; CONFIDENCE-INTERVALS; POWER;
D O I
10.1007/s12028-016-0319-x
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background Many demographic and physiological variables have been associated with TBI outcomes. However, with small sample sizes, making spurious inferences is possible. This paper explores the effect of sample sizes on statistical relationships between patient variables (both physiological and demographic) and outcome. Methods Data from head-injured patients with monitored arterial blood pressure, intracranial pressure (ICP) and outcome assessed at 6 months were included in this retrospective analysis. A univariate logistic regression analysis was performed to obtain the odds ratio for unfavorable outcome. Three different dichotomizations between favorable and unfavorable outcomes were considered. A bootstrap method was implemented to estimate the minimum sample sizes needed to obtain reliable association between physiological and demographic variables with outcome. Results In a univariate analysis with dichotomized outcome, samples sizes should be generally larger than 100 for reproducible results. Pressure reactivity index, ICP, and ICP slow waves offered the strongest relationship with outcome. Relatively small sample sizes may overestimate effect sizes or even produce conflicting results. Conclusion Low power tests, generally achieved with small sample sizes, may produce misleading conclusions, especially when they are based only on p values and the dichotomized criteria of rejecting/not-rejecting the null hypothesis. We recommend reporting confidence intervals and effect sizes in a more complete and contextualized data analysis.
引用
收藏
页码:103 / 107
页数:5
相关论文
共 18 条
  • [1] Guidelines for the Management of Severe Traumatic Brain Injury: Editor's commentary
    Bullock, M. Ross
    Povlishock, John T.
    [J]. JOURNAL OF NEUROTRAUMA, 2007, 24 : VII - VIII
  • [2] Power failure: why small sample size undermines the reliability of neuroscience
    Button, Katherine S.
    Ioannidis, John P. A.
    Mokrysz, Claire
    Nosek, Brian A.
    Flint, Jonathan
    Robinson, Emma S. J.
    Munafo, Marcus R.
    [J]. NATURE REVIEWS NEUROSCIENCE, 2013, 14 (05) : 365 - 376
  • [3] THINGS I HAVE LEARNED (SO FAR)
    COHEN, J
    [J]. AMERICAN PSYCHOLOGIST, 1990, 45 (12) : 1304 - 1312
  • [4] The statistical recommendations of the American Psychological Association Publication Manual: Effect sizes, confidence intervals, and meta-analysis
    Cumming, Geoff
    Fidler, Fiona
    Kalinowski, Pav
    Lai, Jerry
    [J]. AUSTRALIAN JOURNAL OF PSYCHOLOGY, 2012, 64 (03) : 138 - 146
  • [5] Age, intracranial pressure, autoregulation, and outcome after brain trauma
    Czosnyka, M
    Balestreri, M
    Steiner, L
    Smielewski, P
    Hutchinson, PJ
    Matta, B
    Pickard, JD
    [J]. JOURNAL OF NEUROSURGERY, 2005, 102 (03) : 450 - 454
  • [6] Czosnyka Marek, 2007, Neurosurg Focus, V22, pE10
  • [7] CONFIDENCE-INTERVALS RATHER THAN P-VALUES - ESTIMATION RATHER THAN HYPOTHESIS-TESTING
    GARDNER, MJ
    ALTMAN, DG
    [J]. BMJ-BRITISH MEDICAL JOURNAL, 1986, 292 (6522): : 746 - 750
  • [8] The fickle P value generates irreproducible results
    Halsey, Lewis G.
    Curran-Everett, Douglas
    Vowler, Sarah L.
    Drummond, Gordon B.
    [J]. NATURE METHODS, 2015, 12 (03) : 179 - 185
  • [9] Why most discovered true associations are inflated
    Ioannidis, John P. A.
    [J]. EPIDEMIOLOGY, 2008, 19 (05) : 640 - 648
  • [10] JENNETT B, 1975, LANCET, V1, P480