Development and evaluation of raloxifene hydrochloride-loaded subdermal implants using hot-melt extrusion technology

被引:14
|
作者
Muhindo, Derick [1 ]
Ashour, Eman A. [1 ]
Almutairi, Mashan [1 ,2 ]
Repka, Michael A. [1 ,3 ]
机构
[1] Univ Mississippi, Sch Pharm, Dept Pharmaceut & Drug Delivery, University, MS 38677 USA
[2] Univ Hail, Coll Pharm, Dept Pharmaceut, Hail 81442, Saudi Arabia
[3] Univ Mississippi, Sch Pharm, Pii Ctr Pharmaceut Technol, University, MS 38677 USA
基金
美国国家卫生研究院;
关键词
Raloxifene hydrochloride; Hot-melt extrusion; Subdermal implants; Osteoporosis; Polycaprolactone; Biodegradable; Extended drug release; IN-VITRO RELEASE; TRYPANOCIDAL DRUGS; SUSTAINED-RELEASE; POLY(EPSILON-CAPROLACTONE); OSTEOPOROSIS; PRAZIQUANTEL; POLYESTERS; DEVICES;
D O I
10.1016/j.ijpharm.2022.121834
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Implantable drug delivery systems are known to provide great patient compliance and allow for controlled delivery of drugs over a prolonged period of time. This study aimed to prepare novel polycaprolactone/polyethylene glycol-based raloxifene hydrochloride subdermal solid cylindrical implants using a single-step hot-melt extrusion (HME) continuous process, for the provision of a sustained and prolonged release of RX-HCl as a cornerstone and alternative treatment and prevention option of osteoporosis, most especially post-menopausal osteoporosis, and invasive breast cancer, while providing better clinical outcomes by circumventing clinical and biopharmaceutical hurdles like first-pass metabolism and patient non-adherence and incompliance associated with the oral dosage forms of raloxifene hydrochloride. The 11-mm co-rotating twin-screw extruder was used to prepare the implants. The prepared cylindrical-shaped solid implants with dimensions of 10 mm (length) by 2 mm (diameter) were characterized by DSC, PXRD, FTIR, SEM, and in vitro dissolution analysis. Based on the physicochemical characterization of the prepared implants, the HME fabrication technology and optimized process parameters were determined to be acceptable and suitable. The prepared implants showed no obvious burst release and no significant amounts of drug on the surface of the implants. F-1, F-2, and F-3 implant batches showed a maximum cumulative percent drug release of 82.9%, 42.2%, and 20.6%, respectively, in a period of 30 days, and 100% drug release would be expected in a period of about 40 days (F-1), 72 days (F-2), and up to 150 days (F-3) by simple extrapolation. Interestingly, implant batches with a low drug load exhibited a relatively faster and higher rate of release of the drug compared to implant batches with high drug loading. In the present study, a single-step HME process was successfully used to fabricate RX-HCl-loaded subdermal implants, that could potentially be used as a cornerstone regimen in the treatment and prevention of osteoporosis, most especially post-menopausal osteoporosis, by providing release of RX-HCl over a long time period, and avoiding the clinical inconveniences and possible patient incompliance caused by daily administration of the drug.
引用
收藏
页数:11
相关论文
共 50 条
  • [11] Development and evaluation of a novel biodegradable implants with excellent inflammatory response suppression effect by hot-melt extrusion
    Fan, Rangrang
    Chuan, Di
    Hou, Huan
    Chen, Haifeng
    Xu, Jianguo
    Guo, Gang
    EUROPEAN JOURNAL OF PHARMACEUTICAL SCIENCES, 2021, 166
  • [12] Development and evaluation of an oral fast disintegrating anti-allergic film using hot-melt extrusion technology
    Pimparade, Manjeet B.
    Vo, Anh
    Maurya, Abhijeet S.
    Bae, Jungeun
    Morott, Joseph T.
    Feng, Xin
    Kim, Dong Wuk
    Kulkarni, Vijay I.
    Tiwari, Roshan
    Vanaja, K.
    Murthy, Reena
    Shivakumar, H. N.
    Neupane, D.
    Mishra, S. R.
    Murthy, S. N.
    Repka, Michael A.
    EUROPEAN JOURNAL OF PHARMACEUTICS AND BIOPHARMACEUTICS, 2017, 119 : 81 - 90
  • [13] Hot-Melt Extrusion: a Roadmap for Product Development
    Simoes, Marta F.
    Pinto, Rui M. A.
    Simoes, Sergio
    AAPS PHARMSCITECH, 2021, 22 (05)
  • [14] Hot-Melt Extrusion: a Roadmap for Product Development
    Marta F. Simões
    Rui M. A. Pinto
    Sérgio Simões
    AAPS PharmSciTech, 22
  • [15] QbD-Based Development and Evaluation of Pazopanib Hydrochloride Extrudates Prepared by Hot-Melt Extrusion Technique: In Vitro and In Vivo Evaluation
    Gupta, Amit
    Dahima, Rashmi
    Panda, Sunil K.
    Gupta, Annie
    Singh, Gaurav Deep
    Wani, Tanveer A.
    Hussain, Afzal
    Rathore, Devashish
    PHARMACEUTICS, 2024, 16 (06)
  • [16] Advances in hot-melt extrusion technology toward pharmaceutical objectives
    Hwang I.
    Kang C.-Y.
    Park J.-B.
    Journal of Pharmaceutical Investigation, 2017, 47 (2) : 123 - 132
  • [17] A Novel Approach for the Development of a Nanostructured Lipid Carrier Formulation by Hot-Melt Extrusion Technology
    Bhagurkar, Ajinkya M.
    Repka, Michael A.
    Murthy, S. Narasimha
    JOURNAL OF PHARMACEUTICAL SCIENCES, 2017, 106 (04) : 1085 - 1091
  • [18] Formulation, Development, and Characterization of AMB-Based Subcutaneous Implants using PCL and PLGA via Hot-Melt Extrusion
    Chitnis, Kshitij
    Narala, Nagarjuna
    Vemula, Sateesh Kumar
    Narala, Sagar
    Munnangi, Sivaram
    Repka, Michael A.
    AAPS PHARMSCITECH, 2024, 26 (01):
  • [19] Production of Lysozyme-PLGA-Loaded Microparticles for Controlled Release Using Hot-Melt Extrusion
    Farinha, Susana
    Moura, Claudia
    Afonso, Maria Dina
    Henriques, Joao
    AAPS PHARMSCITECH, 2020, 21 (07)
  • [20] Production of Lysozyme-PLGA-Loaded Microparticles for Controlled Release Using Hot-Melt Extrusion
    Susana Farinha
    Cláudia Moura
    Maria Diná Afonso
    João Henriques
    AAPS PharmSciTech, 21