Simultaneous measurement of folate cycle intermediates in different biological matrices using liquid chromatography-tandem mass spectrometry

被引:27
|
作者
Nandania, Jatin [1 ,3 ]
Kokkonen, Meri [1 ,4 ]
Euro, Liliya [2 ]
Velagapudi, Vidya [1 ]
机构
[1] Univ Helsinki, Metabol Unit, Inst Mol Med Finland FIMM, HiLIFE, Tukholmankatu 8,Biomed 2U, FIN-00290 Helsinki, Finland
[2] Univ Helsinki, Res Programmes Unit, Mol Neurol, Biomed 1, FIN-00290 Helsinki, Finland
[3] Roche Diagnost GmbH, Nonnenwald 2, D-82377 Penzberg, Germany
[4] Finnish Customs Lab, Tekniikantie 13, Espoo 02150, Finland
基金
芬兰科学院;
关键词
Folate cycle metabolites; Mass spectrometry; Chromatography; biological matrices; analytical method; validation; ONE-CARBON METABOLISM; MICROBIOLOGIC ASSAY;
D O I
10.1016/j.jchromb.2018.06.008
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The folate cycle is an essential metabolic pathway in the cell, involved in nucleotide synthesis, maintenance of the redox balance in the cell, methionine metabolism and re-methylation reactions. Standardised methods for the measurement of folate cycle intermediates in different biological matrices are in great demand. Here we describe a rapid, sensitive, precise and accurate liquid chromatographic-tandem mass spectrometric (LC-MS/ MS) method with a wide calibration curve range and a short run time for the simultaneous determination of folate cycle metabolites, including tetrahydrofolic acid (THF), 5-methyl THF, 5-formyl THF, 5,10-methenyl THF, 5,10-methylene THF, dihydrofolic acid (DHF) and folic acid in different biological matrices. Extraction of folate derivatives from soft and hard tissue samples as well as from adherent cells was achieved using homogenisation in buffer, while extraction from the whole blood and plasma relied on the anion exchange solid-phase extraction (SPE) method. Chromatographic separation was completed using a Waters Atlantis dC(18) 2.0 x 100 mm, 3-mu column with a gradient elution using formic acid in water (0.1% v/v) and acetonitrile as the mobile phases. LC gradient started with 95% of the aqueous phase which was gradually changed to 95% of the organic phase during 2.70 min in order to separate the selected metabolites. The analytes were separated with a run time of 5 min at a flow rate of 0.300 mL/min and detected using a Waters Xevo-TQS triple quadrupole mass spectrometer in the multiple reaction monitoring mode (MRM) at positive polarity. The instrument response was linear over a calibration range of 0.5 to 2500ng/mL (r(2) > 0.980). The developed bioanalytical method was thoroughly validated in terms of accuracy, precision, linearity, recovery, sensitivity and stability for tissue and blood samples. The matrix effect was compensated by using structurally similar isotope labelled internal standard (IS), C-13(5)-methyl THF, for all folate metabolites. However, not all folate metabolites can be accurately quantified using this method due to their high interconversion rates especially at low pH. This applies to 5,10-methylene THF which interconverts into THF, and 5,10-methenyl-THF interconverting into 5-formyl-THF. Using this method, we measured folate cycle intermediates in mouse bone marrow cells and plasma, in human whole blood; in mouse muscle, liver, heart and brain samples.
引用
收藏
页码:168 / 178
页数:11
相关论文
共 50 条
  • [1] Analysis of β-agonists in different biological matrices by liquid chromatography-tandem mass spectrometry
    Sniegocki, Tomasz
    Sell, Bartosz
    Posyniak, Andrzej
    JOURNAL OF VETERINARY RESEARCH, 2021, 65 (04) : 469 - 475
  • [2] Determination of Corticosteroids in Different Matrices Using Liquid Chromatography-Tandem Mass Spectrometry
    Adam, Tolgyesi
    ProQuest Dissertations and Theses Global, 2011,
  • [3] Simultaneous Measurement of Tricarboxylic Acid Cycle Intermediates in Different Biological Matrices Using Liquid Chromatography-Tandem Mass Spectrometry; Quantitation and Comparison of TCA Cycle Intermediates in Human Serum, Plasma, Kasumi-1 Cell and Murine Liver Tissue
    Rathod, Ramji
    Gajera, Bharat
    Nazir, Kenneth
    Wallenius, Janne
    Velagapudi, Vidya
    METABOLITES, 2020, 10 (03)
  • [4] Analysis of acrylamide in different foodstuffs using liquid chromatography-tandem mass spectrometry and gas chromatography-tandem mass spectrometry
    Hoenicke, K
    Gatermann, R
    Harder, W
    Hartig, L
    ANALYTICA CHIMICA ACTA, 2004, 520 (1-2) : 207 - 215
  • [5] Quantification of urinary folate catabolites using liquid chromatography-tandem mass spectrometry
    Niesser, Mareile
    Harder, Ulrike
    Koletzko, Berthold
    Peissner, Wolfgang
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2013, 929 : 116 - 124
  • [6] Simultaneous Measurement of Serum Testosterone and Dihydrotestosterone by Liquid Chromatography-Tandem Mass Spectrometry
    Shiraishi, Steve
    Lee, Paul W. N.
    Leung, Andrew
    Goh, Victor H. H.
    Swerdloff, Ronald S.
    Wang, Christina
    CLINICAL CHEMISTRY, 2008, 54 (11) : 1855 - 1863
  • [7] Simultaneous Method for Selected PBDEs and HBCDDs in Foodstuffs Using Gas Chromatography-Tandem Mass Spectrometry and Liquid Chromatography-Tandem Mass Spectrometry
    Lipicar, Eva
    Fras, Danijela
    Javernik, Nino
    Prosen, Helena
    TOXICS, 2023, 11 (01)
  • [8] Measurement of cystine in granulocytes using liquid chromatography-tandem mass spectrometry
    Chabli, A.
    Aupetit, J.
    Raehm, M.
    Ricquier, D.
    Chadefaux-Vekemans, B.
    CLINICAL BIOCHEMISTRY, 2007, 40 (9-10) : 692 - 698
  • [9] Measurement of cyclooxygenase inhibition using liquid chromatography-tandem mass spectrometry
    Cao, Hongmei
    Yu, Rui
    Tao, Yi
    Nikolic, Dejan
    van Breemen, Richard B.
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2011, 54 (01) : 230 - 235
  • [10] Liquid Chromatography-Tandem Mass Spectrometry Analysis of Folate and Folate Catabolites in Human Serum
    Hannisdal, Rita
    Ueland, Per Magne
    Svardal, Asbjorn
    CLINICAL CHEMISTRY, 2009, 55 (06) : 1147 - 1154