Some industrial applications of gamma-ray tomography

被引:45
作者
Kalaga, Dinesh V. [1 ]
Kulkarni, Anand V. [1 ]
Acharya, Rajesh [2 ]
Kumar, Umesh [2 ]
Singh, Gurusharan [2 ]
Joshi, Jyeshtharaj B. [1 ]
机构
[1] Inst Chem Technol, Mumbai 400019, Maharashtra, India
[2] Bhabha Atom Res Ctr, Isotope Ind Div, Bombay 400085, Maharashtra, India
关键词
Tomography; Gamma-ray; Packed column; Scanning; Image reconstruction; PACKED-COLUMNS; FLOW DISTRIBUTION; LIQUID HOLDUP; GAS; SYSTEMS; REACTOR; PROFILES;
D O I
10.1016/j.jtice.2009.05.012
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Various tomographic techniques such as electrical capacitance, electrical resistivity, MRI, X-ray/gamma-ray tomography have been reviewed with special emphasis on applicability for the industrial set-ups are discussed. It was found that gamma-ray tomography is most suitable technique which could be used for industrial set-ups. Gamma-ray tomography was also applied for variety of industrial equipment, such as paddle bed dryer, packed distillation column, to explore the possibility of their use for diagnosis of unidentified problems. From the preset work it is recommended to undertake tomographic scanning of critical equipments periodically to enhance the efficiency and reduce possible downtime. (C) 2009 Published by Elsevier B.V. on behalf of Taiwan Institute of Chemical Engineers.
引用
收藏
页码:602 / 612
页数:11
相关论文
共 29 条
[1]  
[Anonymous], 1983, MEASUREMENT DETECTIO
[2]   MAPPING SOLID CONCENTRATION IN A CIRCULATING FLUID BED USING GAMMAMETRY [J].
AZZI, M ;
TURLIER, P ;
BERNARD, JR ;
GARNERO, L .
POWDER TECHNOLOGY, 1991, 67 (01) :27-36
[3]   MEASURING SOLIDS CONCENTRATION IN FLUIDIZED SYSTEMS BY GAMMA-RAY ABSORPTION [J].
BARTHOLOMEW, RN ;
CASAGRANDE, RM .
INDUSTRIAL AND ENGINEERING CHEMISTRY, 1957, 49 (03) :428-431
[4]   Quantitative measurement of gas hold-up distribution in a stirred chemical reactor using X-ray cone-beam computed tomography [J].
Boden, Stephan ;
Bieberle, Martina ;
Hampel, Uwe .
CHEMICAL ENGINEERING JOURNAL, 2008, 139 (02) :351-362
[5]   Imaging immiscible liquid-liquid systems by capacitance tomography [J].
Bolton, GT ;
Korchinsky, WJ ;
Waterfall, RC .
CHEMICAL ENGINEERING RESEARCH & DESIGN, 1999, 77 (A8) :699-708
[6]   Measurement of liquid flow distribution in trickle bed reactor of large diameter with a new gamma-ray tomographic system [J].
Boyer, C ;
Fanget, B .
CHEMICAL ENGINEERING SCIENCE, 2002, 57 (07) :1079-1089
[7]   X-ray computer tomography - potential and limitation for the measurement of local solids distribution in circulating fluidized beds [J].
Grassler, T ;
Wirth, KE .
CHEMICAL ENGINEERING JOURNAL, 2000, 77 (1-2) :65-72
[8]   ANALYSIS OF GAS-FLUIDIZED SOLID SYSTEMS BY X-RAY ABSORPTION [J].
GROHSE, EW .
AICHE JOURNAL, 1955, 1 (03) :358-365
[9]   Gas and liquid phase distribution and their effect on reactor performance in the monolith film flow reactor [J].
Heibel, AK ;
Scheenen, TWJ ;
Heiszwolf, JJ ;
Van As, H ;
Kapteijn, F ;
Moulijn, JA .
CHEMICAL ENGINEERING SCIENCE, 2001, 56 (21-22) :5935-5944
[10]  
HESSELINK L, 1989, HDB FLOW VISUALIZATI, P307