Active damping control of a high power PWM current source rectifier for line current THD reduction

被引:2
|
作者
Wiseman, J [1 ]
Wu, B [1 ]
机构
[1] Rockwell Automat Canada, Cambridge, ON N1R 5X1, Canada
关键词
D O I
10.1109/PESC.2004.1355807
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The use of active damping to reduce the total harmonic distortion (THD) of the line current for medium voltage (2.3KV to 7.2KV) high-power PWM current source rectifiers is investigated. The rectifier requires an LC filter connected at its input terminals, which constitutes an LC resonant mode. The lightly damped LC filter is prone to series and parallel resonances when tuned to a system harmonic either from the utility or from the PWM rectifier. These issues are traditionally addressed at the design stage by properly choosing the filter resonant frequency. This approach may result in a limited performance since the LC resonant frequency is a function of the power system impedance, which usually varies with power system operating conditions. In this paper, an active damping control method is proposed for the reduction in line current THD of high power current source rectifiers operating at a switching frequency of only 540Hz. Two types of LC resonances are investigated: the parallel resonance excited by harmonic currents drawn by the rectifier and the series resonance caused by harmonic pollution in the source voltage. It is demonstrated through simulation and experiments that the proposed active damping control can effectively reduce the line current THD caused by both parallel and series resonances.
引用
收藏
页码:552 / 557
页数:6
相关论文
共 50 条
  • [21] Five-Phase PWM Current Source Rectifier
    Masoud, Mahmoud I.
    Al Abri, R. S.
    2013 7TH IEEE GCC CONFERENCE AND EXHIBITION (GCC), 2013, : 148 - 152
  • [22] Decoupling control strategy of current-source PWM rectifier with capacitive load
    Zhang, Yu (zyu1126@mail.hust.edu.cn), 1600, China Machine Press (31):
  • [23] Performance improvement of active filter for power distribution line using current source PWM inverter
    Nagoya Inst of Technology
    Electr Eng Jpn, 4 (109-119):
  • [24] Performance improvement of active filter for power distribution line using current source PWM inverter
    Matsunami, S
    Yamamura, N
    Tsunehiro, Y
    ELECTRICAL ENGINEERING IN JAPAN, 1996, 116 (04) : 109 - 119
  • [25] Performance improvement of active filter for power distribution line using current source PWM inverter
    Matsunami, S.
    Yamamura, N.
    Tunehiro, Y.
    Denki Gakkai Ronbunshi. D, Sangyo Oyo Bumonshi, 1995, 115 (06):
  • [26] Predictive Current Control of a Current-Source Inverter with Active Damping Method
    Du, Chunshui
    Zhou, Jiangwei
    Ma, Yiwei
    2015 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2015, : 1100 - 1104
  • [27] A three-switch current-source PWM rectifier with active filter function
    Salo, M
    2005 IEEE 36TH POWER ELECTRONIC SPECIALISTS CONFERENCE (PESC), VOLS 1-3, 2005, : 2230 - 2236
  • [28] Low-frequency Leakage Current Reduction using Active Control of Single-phase PWM Rectifier
    Dong, Dong
    Boroyevich, Dushan
    Mattavelli, Paolo
    2011 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2011, : 3778 - 3785
  • [29] Novel control strategy of instantaneous-power based current-source PWM rectifier and experimental results
    Nagaoka University of Technology, 1603-1, Kamitomioka, Nagaoka 940-2188, Japan
    不详
    IEEJ Trans. Ind Appl., 2006, 11 (1486-1492+9):
  • [30] A NOVEL LOAD CURRENT CONTROL METHOD FOR A LEADING POWER-FACTOR VOLTAGE-SOURCE PWM RECTIFIER
    VEAS, DR
    DIXON, JW
    OOI, BT
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 1994, 9 (02) : 153 - 159