Controlling the surface chemistry and chromatography properties of methyacrylate-ester-based monolithic capillary colums via photografting

被引:78
作者
Eeltink, Sebastiaan
Hilder, Emily F.
Geiser, Laurent
Svec, Frantisek
Frechet, Jean M. J.
Rozing, Gerard P.
Schoenmakers, Peter J.
Kok, Wim Th.
机构
[1] Univ Amsterdam, Vant Hoff Inst Mol Sci, Polymer Anal Grp, NL-1018 WV Amsterdam, Netherlands
[2] Univ Calif Berkeley, Dept Chem, Berkeley, CA 94720 USA
[3] EO Lawrence Berkeley natl Lab, Mol Foundry, Berkeley, CA USA
[4] Univ Tasmania, Sch Chem, Australian Ctr Res Separat Sci, ACROSS, Hobart, Tas, Australia
[5] Agilent Technol, Pharmaceut Solut, Life Sci & Chem Anal, Waldbronn, Germany
关键词
capillary electrochromatography; monolithic columns; photografting; selectivity;
D O I
10.1002/jssc.200600316
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Preparation of monolithic capillary columns for separations in the CEC mode using UV-initiated polymerization of the plain monolith followed by functionalization of its pore surface by photografting has been studied. The first step enabled the preparation of generic poly(butyl methacrylate-co-ethylene dimethacrylate) monoliths with optimized porous properties, controlled by the percentages of porogens 1-decanol and cyclohexanol in the polymerization mixture, irradiation time, and UV light intensity. Ionizable monomers [2-(methacryloyloxy)ethyl]trimethylammonium chloride or 2-acryloamido-2-methyl-1-propanesulfonic acid were then photografted onto the monolithic matrix, allowing us to control the direction of the EOF in CEC. Different strategies were applied to control the grafting density and, thereby, the magnitude of the EOF. To control the hydrophobic properties, two approaches were tested: (i) cografting of a mixture of the ionizable and hydrophobic monomers and (ii) sequential grafting of the ionizable and hydrophobic monomers. Cografting resulted in similar retention but higher EOF. With sequential grafting, more than 50% increase in retention factors was obtained and a slight decrease in EOF was observed due to shielding of the ionizable moieties.
引用
收藏
页码:407 / 413
页数:7
相关论文
共 31 条
  • [1] Silica-based monoliths for capillary electrochromatography: Methods of fabrication and their applications in analytical separations
    Allen, D
    El Rassi, Z
    [J]. ELECTROPHORESIS, 2003, 24 (22-23) : 3962 - 3976
  • [2] Development of acrylate-based monolithic stationary phases for electrochromatographic separations
    Barrioulet, MP
    Delaunay-Bertoncini, N
    Demesmay, C
    Rocca, JL
    [J]. ELECTROPHORESIS, 2005, 26 (21) : 4104 - 4115
  • [3] Novel monolithic materials using poly(ethylene glycol) as porogen for protein separation
    Courtois, J
    Byström, E
    Irgum, K
    [J]. POLYMER, 2006, 47 (08) : 2603 - 2611
  • [4] Surface photograft polymerization of vinyl acetate on low density polyethylene film. Effects of solvent
    Deng, JP
    Yang, WT
    Ranby, B
    [J]. POLYMER JOURNAL, 2000, 32 (10) : 834 - 837
  • [5] Practical aspects of using methacrylate-ester-based monolithic columns in capillary electrochromatography
    Eeltink, S
    Rozing, GP
    Schoenmakers, PJ
    Kok, WT
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2006, 1109 (01) : 74 - 79
  • [6] Performance limits of monolithic and packed capillary columns in high-performance liquid chromatography and capillary electrochromatography
    Eeltink, S
    Desmet, G
    Vivó-Truyols, G
    Rozing, GP
    Schoenmakers, PJ
    Kok, WT
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2006, 1104 (1-2) : 256 - 262
  • [7] Tailoring the morphology of methacrylate ester-based monoliths for optimum efficiency in liquid chromatography
    Eeltink, S
    Herrero-Martinez, JM
    Rozing, GP
    Schoenmakers, PJ
    Kok, WT
    [J]. ANALYTICAL CHEMISTRY, 2005, 77 (22) : 7342 - 7347
  • [8] GUSEV I, 1999, J CHROMATOGR A, V69, P4499
  • [9] Shielded stationary phases based on porous polymer monoliths for the capillary electrochromatography of highly basic biomolecules
    Hilder, EF
    Svec, F
    Fréchet, JMJ
    [J]. ANALYTICAL CHEMISTRY, 2004, 76 (14) : 3887 - 3892
  • [10] HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY ON CONTINUOUS POLYMER BEDS
    HJERTEN, S
    LIAO, JL
    ZHANG, R
    [J]. JOURNAL OF CHROMATOGRAPHY, 1989, 473 (01): : 273 - 275