Surface Characterizations of Mercury-Based Electrodes with the Resulting Micro and Nano Amalgam Wires and Spheres Formations May Reveal Both Gained Sensitivity and Faced Nonstability in Heavy Metal Detection

被引:32
作者
Aragay, Gemma [1 ,2 ]
Puig-Font, Anna [1 ]
Cadevall, Miquel [1 ]
Merkoci, Arben [1 ,3 ]
机构
[1] CSIC, ICN, CIN2, Nanobioelect & Biosensors Grp, Bellaterra 08193, Spain
[2] Univ Autonoma Barcelona, Dept Chem, Bellaterra 08193, Spain
[3] ICREA, Barcelona, Spain
关键词
ANODIC-STRIPPING VOLTAMMETRY; LEAD; CADMIUM; SENSOR; CD; PB; CU;
D O I
10.1021/jp102123w
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Surface characterizations of mercury-coated screen-printed electrodes with interest for electrochemical stripping analysis of heavy metals detection are presented. SEM images and microanalysis data of the working electrode surface show a homogeneous distribution of mercury film prior to sensor application in heavy metals detection in seawater. The response stability during the 16 days measuring period in terms of RSD (relative standard deviation) was 33%, 24%, and 7.7% for Cd2+, Pb2+, and Cu2+, respectively. Detection limits lower than 7.0 mu g L-1 in a seawater matrix modified with HCl arc achieved for the three metals. The microscopic and microanalysis studies revealed some damages of the mercury film after a long period of use (continuous measuring) of the SPE. The decrease of the sensitivity as well as splitting of the peaks is related to the deposition and stripping of heavy metals in mixed mercury and "mercury free" areas. The application of this sensor for a longer period would need the use of a less acidic medium so as to avoid the damage of the working electrode. This would need further optimizations so as to find a compromise between sensitivity and stability. The frequency of measurements with interest for application in an automatic control system where the sensor may be integrated and applied in the future should also be considered. Moreover, the deposition of metals into the surface of the electrode was evaluated. Surface characterizations of mercury-based electrodes with the resulting micro and nano amalgam wires and spheres formations may in addition reveal both gained sensitivity and faced nonstability while being applied in real water samples.
引用
收藏
页码:9049 / 9055
页数:7
相关论文
共 23 条
  • [1] Anodic stripping voltammetry at a hydrodynamic mercury electrode under high mass transport conditions.: 2.: Experimental verification of theory and implications for sonovoltammetry
    Agra-Gutiérrez, C
    Ball, JC
    Compton, RG
    [J]. JOURNAL OF PHYSICAL CHEMISTRY B, 1998, 102 (36) : 7028 - 7032
  • [2] Electrocatalysis at graphite and carbon nanotube modified electrodes: edge-plane sites and tube ends are the reactive sites
    Banks, CE
    Davies, TJ
    Wildgoose, GG
    Compton, RG
    [J]. CHEMICAL COMMUNICATIONS, 2005, (07) : 829 - 841
  • [3] Banks EC, 1997, NEUROTOXICOLOGY, V18, P237
  • [4] Recent developments in the field of screen-printed electrodes and their related applications
    Dominguez Renedo, O.
    Alonso-Lomillo, M. A.
    Arcos Martinez, M. J.
    [J]. TALANTA, 2007, 73 (02) : 202 - 219
  • [5] Determination of Antimony (III) in Real Samples by Anodic Stripping Voltammetry Using a Mercury Film Screen-Printed Electrode
    Dominguez-Renedo, Olga
    Gomez Gonzalez, M. Jesus
    Julia Arcos-Martinez, M.
    [J]. SENSORS, 2009, 9 (01) : 219 - 231
  • [6] Detection of trace levels of Pb2+ in tap water at boron-doped diamond electrodes with anodic stripping voltammetry
    Dragoe, D
    Spataru, N
    Kawasaki, R
    Manivannan, A
    Spataru, T
    Tryk, DA
    Fujishima, A
    [J]. ELECTROCHIMICA ACTA, 2006, 51 (12) : 2437 - 2441
  • [7] EURACHEM, 1998, LAB GUID METH VAL RE
  • [8] An Innovative Continuous Flow System for Monitoring Heavy Metal Pollution in Water Using Transgenic Xenopus laevis Tadpoles
    Fini, Jean-Baptiste
    Pallud-Mothre, Sophie
    Le Mevel, Sebastien
    Palmier, Karima
    Havens, Christopher M.
    Le Brun, Matthieu
    Mataix, Vincent
    Lemkine, Gregory F.
    Demeneix, Barbara A.
    Turque, Nathalie
    Johnson, Paul E.
    [J]. ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2009, 43 (23) : 8895 - 8900
  • [9] GRANADO MA, 2008, ELECTROANAL, V20, P2608
  • [10] Sensitive and stable monitoring of lead and cadmium in seawater using screen-printed electrode and electrochemical stripping analysis
    Gueell, Raquel
    Aragay, Gemma
    Fontas, Claudia
    Antico, Enriqueta
    Merkoci, Arben
    [J]. ANALYTICA CHIMICA ACTA, 2008, 627 (02) : 219 - 224