An implantable telemetry platform system for in vivo monitoring of physiological parameters

被引:66
作者
Valdastri, P [1 ]
Menciassi, A [1 ]
Arena, A [1 ]
Caccamo, C [1 ]
Dario, P [1 ]
机构
[1] CRIM Lab, Scuola Super Sant Anna, I-56025 Pisa, Italy
来源
IEEE TRANSACTIONS ON INFORMATION TECHNOLOGY IN BIOMEDICINE | 2004年 / 8卷 / 03期
关键词
biotelmetry; data acquisition; implantable devices; in vivo monitoring; wireless sensors;
D O I
10.1109/TITB.2004.834389
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
This paper describes a microcontroller-based multichannel telemetry system, suitable for in vivo monitoring of physiological parameters. The device can digitalize and transmit up to three analog signals coming from different sensors. The telemetry transmission is obtained by using a carrier frequency of 433.92 MHz and an amplitude-shift keying modulation. The signal data rate is 13 kb/s per channel. The digital microcontroller provides good flexibility and interesting performance, such as the threshold monitoring, the transmission error detection, and a low power consumption, thanks to the implementation of a sleep mode. The small overall size (less than 1 cm(3)), the power density compatible with current regulations for the design of implantable devices, and the dedicated packaging make the system suitable for in vivo monitoring in humans. The design, fabrication, operation, packaging, and performance of the system are described in this paper. An in vivo pressure monitoring case study is described as well.
引用
收藏
页码:271 / 278
页数:8
相关论文
共 17 条
[1]  
Ahlbom A, 1998, HEALTH PHYS, V74, P494
[2]  
Endonetics Inc., 2000, International Patent, Patent No. [WO00/59376, 0059376]
[3]   Wireless capsule endoscopy [J].
Iddan, G ;
Meron, G ;
Glukhovsky, A ;
Swain, P .
NATURE, 2000, 405 (6785) :417-417
[4]  
KWAN KY, 2002, P 9 INT C EL CIRC SY, V3, P1211
[6]   A TELEMETRY-INSTRUMENTATION SYSTEM FOR CHRONICALLY IMPLANTED GLUCOSE AND OXYGEN SENSORS [J].
MCKEAN, BD ;
GOUGH, DA .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1988, 35 (07) :526-532
[7]   The development of the swallowable video capsule (M2A) [J].
Meron, GD .
GASTROINTESTINAL ENDOSCOPY, 2000, 52 (06) :817-819
[8]   ECHO CAPSULE FOR MEDICAL USE (A BATTERYLESS ENDORADIOSONDE) [J].
NAGUMO, J ;
HORI, M ;
KIMOTO, S ;
UCHIYAMA, A ;
SUMA, K ;
WATANABE, H ;
OUCHI, A ;
WATANUKI, T ;
KUMANO, M .
IRE TRANSACTIONS ON BIOMEDICAL ELECTRONICS, 1962, BME9 (03) :195-&
[9]   Golden accomplishments in biomedical engineering [J].
Nebeker, F .
IEEE ENGINEERING IN MEDICINE AND BIOLOGY MAGAZINE, 2002, 21 (03) :17-47
[10]   Design of bi-directional and multi-channel miniaturized telemetry module for wireless endoscopy [J].
Park, HJ ;
Nam, HW ;
Song, BS ;
Choi, JL ;
Choi, HC ;
Park, JC ;
Kim, MN ;
Lee, JT ;
Cho, JH .
2ND ANNUAL INTERNATIONAL IEEE-EMBS SPECIAL TOPIC CONFERENCE ON MICROTECHNOLOGIES IN MEDICINE & BIOLOGY, PROCEEDINGS, 2002, :273-276