EUS-guided core biopsies of pancreatic solid masses using a new fork-tip needle: A multicenter prospective study

被引:39
作者
Di Leo, Milena [1 ,2 ]
Crino, Stefano Francesco [3 ]
Bernardoni, Laura [3 ]
Rahal, Daoud [4 ]
Auriemma, Francesco [1 ]
Correale, Loredana [6 ]
Donato, Giulio [5 ]
Massidda, Marco [1 ]
Anderloni, Andrea [1 ]
Manfrin, Erminia [7 ]
Armellini, Elia [5 ]
Poliani, Laura [1 ]
Fugazza, Alessandro [1 ]
Semeraro, Rossella [1 ]
Occhipinti, Pietro [5 ]
Repici, Alessandro [1 ,2 ]
Carrara, Silvia [1 ]
机构
[1] Humanitas Res Hosp, Div Gastroenterol, Digest Endoscopy Unit, Via Manzoni 56, I-20089 Milan, Italy
[2] Humanitas Univ, Dept Biomed Sci, Milan, Italy
[3] GB Rossi Univ Hosp, Pancreas Inst, Gastroenterol & Digest Endoscopy Unit, Verona, Italy
[4] Humanitas Res Hosp, Pathol Dept, Milan, Italy
[5] Osped Maggiore La Carita, Digest Endoscopy Unit, Novara, Italy
[6] Ctr Prevenz Oncol, Turin, Italy
[7] GB Rossi Univ Hosp, Dept Diagnost & Publ Hlth, Verona, Italy
关键词
FNA; FNB; Pancreatic adenocarcinoma; SharkCore needle; Tissue acquisition; DIAGNOSTIC-ACCURACY; TISSUE ACQUISITION; ASPIRATION; LESIONS; 22-GAUGE; FNA; TRIAL;
D O I
10.1016/j.dld.2019.03.025
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background and aim: Endoscopic ultrasound-guided sampling (EUS sampling) is a safe and effective technique. The study aim was to evaluate the presence of a histological core from pancreatic lesions using a new 25G fork-tip needle. Methods: Observational multicenter prospective and analytical study, including consecutive patients with solid pancreatic masses referred for EUS-guided sampling. At each needle pass, the endoscopist performed macroscopic on-site evaluation (MOSE). The primary outcome was the histological core procurement rates. Secondary outcomes were the evaluation of interobserver agreement between endoscopists and pathologists, adequacy of EUS samples for the diagnosis and post-procedure adverse events. Results: 100 patients were enrolled in 3 centers. The mean size of the lesions was 28.5 mm (SD 11.7). Final diagnoses were adenocarcinoma (68%), neuroendocrine tumor (21%), inflammatory mass/benign lesions (8.0%), and pancreatic metastasis (3.0%). The pathologists described the presence of a core in 67 samples (67.0% of patients), with poor agreement with MOSE (kappa, 0. 12; 95% CI: 0.03-0.28). The diagnostic accuracy was 93%. We observed 6% of mild adverse events. Conclusion: The new 25-gauge core needle showed good overall adequacy and a good rate of histological specimens during EUS sampling of solid pancreatic masses, with a minimum number of passes and no major complications. (C) 2019 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:1275 / 1280
页数:6
相关论文
共 50 条
  • [21] Prospective Assessment of the Performance of a New Fine Needle Biopsy Device for EUS-Guided Sampling of Solid Lesions
    El Hajj, Ihab I.
    Wu, Howard
    Reuss, Sarah
    Randolph, Melissa
    Harris, Akeem
    Gromski, Mark A.
    Al-Haddad, Mohammad
    CLINICAL ENDOSCOPY, 2018, 51 (06) : 576 - 583
  • [22] Diagnosis of autoimmune pancreatitis by EUS-guided FNA using a 22-gauge needle: a prospective multicenter study
    Kanno, Atsushi
    Masamune, Atsushi
    Fujishima, Fumiyoshi
    Iwashita, Takuji
    Kodama, Yuzo
    Katanuma, Akio
    Ohara, Hirotaka
    Kitano, Masayuki
    Inoue, Hiroyuki
    Itoi, Takao
    Mizuno, Nobumasa
    Miyakawa, Hiroyuki
    Mikata, Rintaro
    Irisawa, Atsushi
    Sato, Satoko
    Notohara, Kenji
    Shimosegawa, Tooru
    GASTROINTESTINAL ENDOSCOPY, 2016, 84 (05) : 797 - +
  • [23] EUS-guided fine needle biopsy of pancreatic masses can yield true histology
    Bang, Ji Young
    Hebert-Magee, Shantel
    Navaneethan, Udayakumar
    Hasan, Muhammad K.
    Hawes, Robert
    Varadarajulu, Shyam
    GUT, 2018, 67 (12) : 2081 - +
  • [24] Impact of EUS-guided fine-needle biopsy sampling with a new core needle on the need for onsite cytopathologic assessment: a preliminary study
    Rodrigues-Pinto, Eduardo
    Jalaj, Sujai
    Grimm, Ian S.
    Baron, Todd H.
    GASTROINTESTINAL ENDOSCOPY, 2016, 84 (06) : 1040 - 1046
  • [25] Performance of a new flexible 19 G EUS needle in pancreatic solid lesions located in the head and uncinate process: A prospective multicenter study
    Gines, Angels
    Fusaroli, Pietro
    Sendino, Oriol
    Seicean, Andrada
    Gimeno-Garcia, Antonio Z.
    Gratacos-Gines, Jordi
    Araujo, Isis K.
    Rodriguez-Carunchio, Leonardo
    Alos, Silvia
    Lisotti, Andrea
    Cominardi, Anna
    Montenegro, Andrea
    Fernandez-Esparrach, Gloria
    ENDOSCOPY INTERNATIONAL OPEN, 2021, 09 (08) : E1269 - E1275
  • [26] Optimal sampling technique for EUS-guided fine-needle biopsy of solid pancreatic lesions using a 25-gauge ProCore needle: A multicenter randomized crossover superiority study
    Li, Shi-Yu
    Shi, Lei
    Yao, Jun
    Zhou, Wei
    Wang, Zhi-Jie
    Jiang, Yue-Ping
    Wang, Xiao-Wei
    Zhou, Chun-Hua
    Gao, Li
    Jiang, Hui
    Chen, Ying
    Li, Zhao-Shen
    Jin, Zhen-Dong
    Wang, Kai-Xuan
    ENDOSCOPIC ULTRASOUND, 2022, 11 (06) : 466 - 477
  • [27] Per-Pass Performance Characteristics of Endoscopic Ultrasound-Guided Fine-Needle Aspiration of Malignant Solid Pancreatic Masses in a Large Multicenter Cohort
    Ge, Phillip S.
    Wani, Sachin
    Watson, Rabindra R.
    Sedarat, Alireza
    Kim, Stephen
    Marshall, Carrie
    Wilson, Robert H.
    Makker, Jitin
    Mohamadnejad, Mehdi
    Komanduri, Srinadh
    Muthusamy, V. Raman
    PANCREAS, 2018, 47 (03) : 296 - 301
  • [28] Comparison of the diagnostic performance of new torque technique by twisting the scope with standard technique for EUS-guided tissue acquisition in solid pancreatic lesions: A multicenter prospective randomized study
    Park, Se Woo
    Lee, Sang Soo
    JOURNAL OF GASTROENTEROLOGY AND HEPATOLOGY, 2018, 33 : 188 - 188
  • [29] EUS-guided tissue acquisition in chronic pancreatitis: Differential diagnosis between pancreatic cancer and pseudotumoral masses using EUS-FNA or core biopsy
    Grassia, Roberto
    Imperatore, Nicola
    Capone, Pietro
    Cereatti, Fabrizio
    Forti, Edoardo
    Antonini, Filippo
    Tanzi, Giulia Paola
    Martinotti, Mario
    Buffoli, Federico
    Mutignani, Massimiliano
    Macarri, Giampiero
    Manes, Gianpiero
    Vecchi, Maurizio
    De Nucci, Germana
    ENDOSCOPIC ULTRASOUND, 2020, 9 (02) : 122 - 129
  • [30] EUS-Guided 22-Gauge Fine-Needle Aspiration Versus Core Biopsy Needle in the Evaluation of Solid Pancreatic Neoplasms
    Strand, Daniel S.
    Jeffus, Susanne K.
    Sauer, Bryan G.
    Wang, Andrew Y.
    Stelow, Edward B.
    Shami, Vanessa M.
    DIAGNOSTIC CYTOPATHOLOGY, 2014, 42 (09) : 751 - 758