Phase-Contrast Micro-Computed Tomography Measurements of the Intraocular Pressure-Induced Deformation of the Porcine Lamina Cribrosa

被引:47
|
作者
Coudrillier, Baptiste [1 ,2 ]
Geraldes, Diogo M. [3 ]
Vo, Nghia T. [4 ]
Atwood, Robert [4 ]
Reinhard, Christina [4 ]
Campbell, Ian C. [1 ,2 ,5 ]
Raji, Yazdan [1 ,2 ]
Albon, Julie [6 ,7 ]
Abel, Richard L. [8 ]
Ethier, C. Ross [1 ,2 ,5 ]
机构
[1] Georgia Inst Technol, Wallace H Coulter Dept Biomed Engn, Atlanta, GA 30332 USA
[2] Emory Univ, Atlanta, GA 30332 USA
[3] Univ London Imperial Coll Sci Technol & Med, Biomech Grp, Dept Mech Engn, London SW7 2AZ, England
[4] Diamond Light Source Ltd, Harwell Sci & Innovat Campus, Didcot OX11 0QX, Oxon, England
[5] Atlanta VA Med Ctr, Decatur, GA 30033 USA
[6] Cardiff Univ, Sch Optometry & Vis Sci, Opt Nerve Grp, Cardiff CF24 4HQ, S Glam, Wales
[7] Cardiff Univ, Cardiff Inst Tissue Engn Repair, Cardiff CF24 4HQ, S Glam, Wales
[8] Univ London Imperial Coll Sci Technol & Med, Dept Surg & Canc, London SW7 2AZ, England
关键词
Biomechanics; strain measurements; x-ray tomography; OPTIC-NERVE HEAD; DIGITAL VOLUME CORRELATION; CONNECTIVE-TISSUE; STRAIN; GLAUCOMA; BONE; ELEVATION; DISPLACEMENT; BIOMECHANICS; REMOVAL;
D O I
10.1109/TMI.2015.2504440
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
The lamina cribrosa (LC) is a complex mesh-like tissue in the posterior eye. Its biomechanical environment is thought to play a major role in glaucoma, the second most common cause of blindness. Due to its small size and relative inaccessibility, high-resolution measurements of LC deformation, important in characterizing LC biomechanics, are challenging. Here we present a novel noninvasive imaging method, which enables measurement of the three-dimensional deformation of the LC caused by acute elevation of intraocular pressure (IOP). Posterior segments of porcine eyes were imaged using synchrotron radiation phase contrast micro-computed tomography (PC mu CT) at IOPs between 6 and 37 mmHg. The complex trabecular architecture of the LC was reconstructed with an isotropic spatial resolution of 3.2 mu m. Scans acquired at different IOPs were analyzed with digital volume correlation (DVC) to compute full-field deformation within the LC. IOP elevation caused substantial tensile, shearing and compressive devformation within the LC, with maximum tensile strains at 30 mmHg averaging 5.5%, and compressive strains reaching 20%. We conclude that PC mu CT provides a novel high-resolution method for imaging the LC, and when combined with DVC, allows for full-field 3D measurement of ex vivo LC biomechanics at high spatial resolution.
引用
收藏
页码:988 / 999
页数:12
相关论文
共 4 条
  • [1] The pressure-induced deformation response of the human lamina cribrosa: Analysis of regional variations
    Midgett, Dan E.
    Pease, Mary E.
    Jefferys, Joan L.
    Patel, Mohak
    Franck, Christian
    Quigley, Harry A.
    Nguyen, Thao D.
    ACTA BIOMATERIALIA, 2017, 53 : 123 - 139
  • [2] Characterization of Deformation and Failure of Fomes fomentarius Hymenium by Synchrotron Phase-Contrast Enhanced Micro-Computed Tomography, In situ Compression Testing and Three-Dimensional Optical Flow
    Klemm, Sophie
    Nogatz, Tessa
    Perrin, Jonathan
    Weitkamp, Timm
    Redenbach, Claudia
    Fleck, Claudia
    SMALL STRUCTURES, 2025, 6 (04):
  • [3] Analysis of the Meso-Mechanical Deformation Behavior of Al Foams and Ni/Al Hybrid Foams Using Time-Lapse Micro-Computed Tomography Measurements and 3D Optical Flow
    Nogatz, Tessa
    Jung, Anne
    Fila, Tomas
    Kumpova, Ivana
    Jirousek, Ondrej
    ADVANCED ENGINEERING MATERIALS, 2024, 26 (24)
  • [4] Organization of Extracellular Matrix Fibers Within Polyglycolic Acid-Polylactic Acid Scaffolds Analyzed Using X-Ray Synchrotron-Radiation Phase-Contrast Micro Computed Tomography
    Albertini, Gianni
    Giuliani, Alessandra
    Komlev, Vladimir
    Moroncini, Francesca
    Pugnaloni, Armanda
    Pennesi, Giuseppina
    Belicchi, Marzia
    Rubini, Corrado
    Rustichelli, Franco
    Tasso, Roberta
    Torrente, Yvan
    TISSUE ENGINEERING PART C-METHODS, 2009, 15 (03) : 403 - 411