R&D on dental implants breakage

被引:5
作者
Croitoru, Sorin Mihai [1 ]
Popovici, Ion Alexandru [2 ]
机构
[1] POLITEHNICA Univ Bucharest, Fac Engn & Management Technol Syst, Machines & Mfg Syst Dept, 313 Spl Independentei,Sect 6, Bucharest, Romania
[2] Univ Med & Pharm Carol Davila, Fac Dent, 19 Calea Plevnei,Sect 1, Bucharest, Romania
关键词
Dental implant; Breakage; FEM simulation; New instruments; Implant restoration;
D O I
10.1016/j.apsusc.2017.02.110
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Most used dental implants for human dental prostheses are of two steps type: first step means implantation and, after several months healing and osseointegration, second step is prosthesis fixture. For sure, dental implants and prostheses are meant to last for a lifetime. Still, there are unfortunate cases when dental implants break. This paper studies two steps dental implants breakage and proposes a set of instruments for replacement and restoration of the broken implant. First part of the paper sets the input data of the study: structure of the studied two steps dental implants based on two Romanian patents and values of the loading forces found in practice and specialty papers. In the second part of the paper, using DEFORM 2DTM FEM simulation software, worst case scenarios of loading dental implants are studied in order to determine which zones and components of the dental implant set are affected (broken). Last part of the paper is dedicated to design and presentation of a set for extracting and cutting tools used to restore the broken implant set. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:262 / 268
页数:7
相关论文
共 10 条
[1]  
[Anonymous], 2007, Romanian patent, Patent No. 121362
[2]  
[Anonymous], 2008, EFORM 2DTM V 9 0 PER
[3]  
Mahajan A, 2014, Int J Sci Res, V3, P1085
[4]  
Mancuso D.N., 2008, DENT TODAY
[5]   A Critical Review of Dental Implant Materials with an Emphasis on Titanium versus Zirconia [J].
Osman, Reham B. ;
Swain, Michael V. .
MATERIALS, 2015, 8 (03) :932-958
[6]   A technique for salvaging an implant-supported crown with a fractured abutment screw [J].
Pow, EHN ;
Wat, PYP .
JOURNAL OF PROSTHETIC DENTISTRY, 2006, 95 (02) :169-170
[7]   EFFECT OF IMPLANTS ON MAXIMUM BITE FORCE IN EDENTULOUS PATIENTS [J].
Rismanchian, Mansour ;
Bajoghli, Farshad ;
Mostajeran, Zahra ;
Fazel, Akbar ;
Eshkevari, P. Sadr .
JOURNAL OF ORAL IMPLANTOLOGY, 2009, 35 (04) :196-200
[8]  
Stanciu R., 2014, Patent No, Patent No. 125886
[9]  
Tokmakidis K., 2009, DTSCH ARZTE VER6AG, V25, P44
[10]  
Verplancke K., 2011, Int. J. Sustain. Constr. Des, V2, P360, DOI [10.21825/scad.v2i3.20534, DOI 10.21825/SCAD.V2I3.20534, DOI 10.1016/J.ECOLECON.2014.05.003]