Assessment and correction of macroscopic field variations in 2D spoiled gradient-echo sequences

被引:1
作者
Soellradl, Martin [1 ]
Lesch, Andreas [2 ]
Strasser, Johannes [1 ]
Pirpamer, Lukas [1 ]
Stollberger, Rudolf [2 ]
Ropele, Stefan [1 ]
Langkammer, Christian [1 ]
机构
[1] Med Univ Graz, Dept Neurol, Auenbruggerpl 22, A-8036 Graz, Austria
[2] Graz Univ Technol, Inst Med Engn, Graz, Austria
基金
奥地利科学基金会;
关键词
field inhomogeneities; myelin water fraction; R-2*; relaxometry; slice profile; T-2*; EXPONENTIAL EXCITATION PULSES; MULTIPLE-SCLEROSIS; T-2-ASTERISK DECAY; BRAIN; ARTIFACTS; CONTRAST; ROBUST; IRON; R-2(ASTERISK); OPTIMIZATION;
D O I
10.1002/mrm.28139
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose To model and correct the dephasing effects in the gradient-echo signal for arbitrary RF excitation pulses with large flip angles in the presence of macroscopic field variations. Methods The dephasing of the spoiled 2D gradient-echo signal was modeled using a numerical solution of the Bloch equations to calculate the magnitude and phase of the transverse magnetization across the slice profile. Additionally, regional variations of the transmit RF field and slice profile scaling due to macroscopic field gradients were included. Simulations, phantom, and in vivo measurements at 3 T were conducted for R2* and myelin water fraction (MWF) mapping. Results The influence of macroscopic field gradients on R2* and myelin water fraction estimation can be substantially reduced by applying the proposed model. Moreover, it was shown that the dephasing over time for flip angles of 60 degrees or greater also depends on the polarity of the slice-selection gradient because of phase variation along the slice profile. Conclusion Substantial improvements in R2* accuracy and myelin water fraction mapping coverage can be achieved using the proposed model if higher flip angles are required. In this context, we demonstrated that the phase along the slice profile and the polarity of the slice-selection gradient are essential for proper modeling of the gradient-echo signal in the presence of macroscopic field variations.
引用
收藏
页码:620 / 633
页数:14
相关论文
共 57 条
[1]   Efficient high-resolution RF pulse design applied to simultaneous multi-slice excitation [J].
Aigner, Christoph Stefan ;
Clason, Christian ;
Rund, Armin ;
Stollberger, Rudolf .
JOURNAL OF MAGNETIC RESONANCE, 2016, 263 :33-44
[2]   Field inhomogeneity correction for gradient echo myelin water fraction imaging [J].
Alonso-Ortiz, Eva ;
Levesque, Ives R. ;
Paquin, Raphael ;
Pike, G. Bruce .
MAGNETIC RESONANCE IN MEDICINE, 2017, 78 (01) :49-57
[3]   Tracking iron in multiple sclerosis: a combined imaging and histopathological study at 7 Tesla [J].
Bagnato, Francesca ;
Hametner, Simon ;
Yao, Bing ;
van Gelderen, Peter ;
Merkle, Hellmut ;
Cantor, Fredric K. ;
Lassmann, Hans ;
Duyn, Jeff H. .
BRAIN, 2011, 134 :3599-3612
[4]  
Bartzokis G, 2000, CELL MOL BIOL, V46, P821
[5]   Rapid Single-Scan T2*-Mapping Using Exponential Excitation Pulses and Image-Based Correction for Linear Background Gradients [J].
Baudrexel, Simon ;
Volz, Steffen ;
Preibisch, Christine ;
Klein, Johannes C. ;
Steinmetz, Helmuth ;
Hilker, Ruediger ;
Deichmann, Ralf .
MAGNETIC RESONANCE IN MEDICINE, 2009, 62 (01) :263-268
[6]  
Brass Steven D, 2006, Top Magn Reson Imaging, V17, P31, DOI 10.1097/01.rmr.0000245459.82782.e4
[7]   Controlled aliasing in volumetric parallel imaging (2D CAIPIRINHA) [J].
Breuer, FA ;
Blaimer, M ;
Mueller, MF ;
Seiberlich, N ;
Heidemann, RM ;
Griswold, MA ;
Jakob, PM .
MAGNETIC RESONANCE IN MEDICINE, 2006, 55 (03) :549-556
[8]   Functional MR imaging using gradient-echo echo-planar imaging in the presence of large static field inhomogeneities [J].
Constable, RT .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1995, 5 (06) :746-752
[9]   Limits of detection of SPIO at 3.0 T using T2* relaxometry [J].
Dahnke, H ;
Schaeffter, T .
MAGNETIC RESONANCE IN MEDICINE, 2005, 53 (05) :1202-1206
[10]  
Does MD., MULTIEXPONENTIAL REL