High Fidelity System Modeling for High Quality Image Reconstruction in Clinical CT

被引:3
|
作者
Do, Synho [1 ,2 ]
Karl, William Clem [3 ]
Singh, Sarabjeet [1 ,2 ]
Kalra, Mannudeep [1 ,2 ]
Brady, Tom [1 ,2 ]
Shin, Ellie [1 ,2 ]
Pien, Homer [1 ,2 ]
机构
[1] Massachusetts Gen Hosp, Dept Radiol, Boston, MA 02114 USA
[2] Harvard Univ, Sch Med, Boston, MA 02115 USA
[3] Boston Univ, Dept Elect & Comp Engn, Boston, MA 02215 USA
来源
PLOS ONE | 2014年 / 9卷 / 11期
关键词
BEAM COMPUTED-TOMOGRAPHY; LOW-DOSE CT; ITERATIVE RECONSTRUCTION; RADIATION; MAXIMUM; REDUCTION; ALGORITHM; FORMULATION; EXPOSURE; MATRIX;
D O I
10.1371/journal.pone.0111625
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Today, while many researchers focus on the improvement of the regularization term in IR algorithms, they pay less concern to the improvement of the fidelity term. In this paper, we hypothesize that improving the fidelity term will further improve IR image quality in low-dose scanning, which typically causes more noise. The purpose of this paper is to systematically test and examine the role of high-fidelity system models using raw data in the performance of iterative image reconstruction approach minimizing energy functional. We first isolated the fidelity term and analyzed the importance of using focal spot area modeling, flying focal spot location modeling, and active detector area modeling as opposed to just flying focal spot motion. We then compared images using different permutations of all three factors. Next, we tested the ability of the fidelity terms to retain signals upon application of the regularization term with all three factors. We then compared the differences between images generated by the proposed method and Filtered-Back-Projection. Lastly, we compared images of low-dose in vivo data using Filtered-Back-Projection, Iterative Reconstruction in Image Space, and the proposed method using raw data. The initial comparison of difference maps of images constructed showed that the focal spot area model and the active detector area model also have significant impacts on the quality of images produced. Upon application of the regularization term, images generated using all three factors were able to substantially decrease model mismatch error, artifacts, and noise. When the images generated by the proposed method were tested, conspicuity greatly increased, noise standard deviation decreased by 90% in homogeneous regions, and resolution also greatly improved. In conclusion, the improvement of the fidelity term to model clinical scanners is essential to generating higher quality images in low-dose imaging.
引用
收藏
页数:12
相关论文
共 50 条
  • [41] High quality image reconstruction with self-pumped phase conjugation
    Miyakawa, K
    Ichinose, M
    Yamashita, M
    ADVANCED MATERIALS AND DEVICES FOR SENSING AND IMAGING, 2002, 4919 : 48 - 53
  • [42] Reduced-Order Modeling of a High-Fidelity Propulsion System Simulation
    Lee, Kyunghoon
    Nam, Taewoo
    Perullo, Christopher
    Mavris, Dimitri N.
    AIAA JOURNAL, 2011, 49 (08) : 1665 - 1682
  • [43] High Fidelity RF Clutter Modeling and Simulation
    Gogineni, Sandeep
    Guerci, Joseph R.
    Nguyen, Hoan K.
    Bergin, Jameson S.
    Kirk, David R.
    Watson, Brian C.
    Rangaswamy, Muralidhar
    IEEE AEROSPACE AND ELECTRONIC SYSTEMS MAGAZINE, 2022, 37 (11) : 24 - 43
  • [44] High-fidelity spectroscopy reconstruction in accelerated NMR
    Qu, Xiaobo
    Qiu, Tianyu
    Guo, Di
    Lu, Hengfa
    Ying, Jiaxi
    Shen, Ming
    Hu, Bingwen
    Orekhov, Vladislav
    Chen, Zhong
    CHEMICAL COMMUNICATIONS, 2018, 54 (78) : 10958 - 10961
  • [45] Effects of High Fidelity Modeling of Multirotor Drones
    Hoang, Samantha
    Marsh, Laurel
    Aliseda, Alberto
    Shen, I.Y.
    Journal of Autonomous Vehicles and Systems, 2021, 1 (01):
  • [46] HIGH FIDELITY MODELING AND SIMULATION FOR SATCOM NETWORKS
    Lee, Junghoon
    Elmasry, George
    Life, Roy
    Phillips, Clifton
    Dave, Nikhil
    Fiscko, Kurt
    MILCOM 2009 - 2009 IEEE MILITARY COMMUNICATIONS CONFERENCE, VOLS 1-4, 2009, : 864 - +
  • [47] Neuralangelo: High-Fidelity Neural Surface Reconstruction
    Li, Zhaoshuo
    Muller, Thomas
    Evans, Alex
    Tayloi, Russell H.
    Unberath, Mathias
    Liu, Ming -Yu
    Lin, Chen-Hsuan
    2023 IEEE/CVF CONFERENCE ON COMPUTER VISION AND PATTERN RECOGNITION (CVPR), 2023, : 8456 - 8465
  • [48] Study of CT image reconstruction algorithm based on high order total variation
    Xi, Yarui
    Qiao, Zhiwei
    Wang, Wenjie
    Niu, Lei
    OPTIK, 2020, 204
  • [49] Predictors of Image Quality in High-Pitch Coronary CT Angiography
    Stolzmann, Paul
    Goetti, Robert P.
    Maurovich-Horvat, Pal
    Hoffmann, Udo
    Flohr, Thomas G.
    Leschka, Sebastian
    Alkadhi, Hatem
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2011, 197 (04) : 851 - 858
  • [50] Image reconstruction and image quality evaluation for a dual source CT scanner
    Flohr, T. G.
    Bruder, H.
    Stierstorfer, K.
    Petersilka, M.
    Schmidt, B.
    McCollough, C. H.
    MEDICAL PHYSICS, 2008, 35 (12) : 5882 - 5897