High Fidelity System Modeling for High Quality Image Reconstruction in Clinical CT

被引:3
|
作者
Do, Synho [1 ,2 ]
Karl, William Clem [3 ]
Singh, Sarabjeet [1 ,2 ]
Kalra, Mannudeep [1 ,2 ]
Brady, Tom [1 ,2 ]
Shin, Ellie [1 ,2 ]
Pien, Homer [1 ,2 ]
机构
[1] Massachusetts Gen Hosp, Dept Radiol, Boston, MA 02114 USA
[2] Harvard Univ, Sch Med, Boston, MA 02115 USA
[3] Boston Univ, Dept Elect & Comp Engn, Boston, MA 02215 USA
来源
PLOS ONE | 2014年 / 9卷 / 11期
关键词
BEAM COMPUTED-TOMOGRAPHY; LOW-DOSE CT; ITERATIVE RECONSTRUCTION; RADIATION; MAXIMUM; REDUCTION; ALGORITHM; FORMULATION; EXPOSURE; MATRIX;
D O I
10.1371/journal.pone.0111625
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Today, while many researchers focus on the improvement of the regularization term in IR algorithms, they pay less concern to the improvement of the fidelity term. In this paper, we hypothesize that improving the fidelity term will further improve IR image quality in low-dose scanning, which typically causes more noise. The purpose of this paper is to systematically test and examine the role of high-fidelity system models using raw data in the performance of iterative image reconstruction approach minimizing energy functional. We first isolated the fidelity term and analyzed the importance of using focal spot area modeling, flying focal spot location modeling, and active detector area modeling as opposed to just flying focal spot motion. We then compared images using different permutations of all three factors. Next, we tested the ability of the fidelity terms to retain signals upon application of the regularization term with all three factors. We then compared the differences between images generated by the proposed method and Filtered-Back-Projection. Lastly, we compared images of low-dose in vivo data using Filtered-Back-Projection, Iterative Reconstruction in Image Space, and the proposed method using raw data. The initial comparison of difference maps of images constructed showed that the focal spot area model and the active detector area model also have significant impacts on the quality of images produced. Upon application of the regularization term, images generated using all three factors were able to substantially decrease model mismatch error, artifacts, and noise. When the images generated by the proposed method were tested, conspicuity greatly increased, noise standard deviation decreased by 90% in homogeneous regions, and resolution also greatly improved. In conclusion, the improvement of the fidelity term to model clinical scanners is essential to generating higher quality images in low-dose imaging.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Optimal Sampling Lattices for High-Fidelity CT Reconstruction
    Mueller, Klaus
    Xu, Fang
    2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 3048 - 3052
  • [2] Optoelectronic image scanning with high spatial resolution and reconstruction fidelity
    Craubner, S
    OPTICAL ENGINEERING, 2002, 41 (02) : 381 - 394
  • [3] High-fidelity reconstruction and computational modeling of metallic microstructure
    Qidwai, M. A. Siddiq
    Geltmacher, A. B.
    Lewis, A. C.
    Rowenhorst, D. J.
    Spanos, G.
    PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION 2007, VOL 12: NEW DEVELOPMENTS IN SIMULATION METHODS AND SOFTWARE FOR ENGINEERING APPLICATIONS, 2008, : 77 - 86
  • [4] High Quality Image Reconstruction of Point Models
    Marroquim, Ricardo
    Oliveira, Antonio
    Cavalcanti, Paulo Roma
    SIBGRAPI 2008: XXI BRAZILIAN SYMPOSIUM ON COMPUTER GRAPHICS AND IMAGE PROCESSING, 2008, : 297 - 304
  • [5] High-Fidelity Clothed Avatar Reconstruction from a Single Image
    Liao, Tingting
    Zheng, Xiaomei
    Xiu, Yuliang
    Yi, Hongwei
    Liu, Xudong
    Qi, Guo-Jun
    Zhang, Yong
    Wang, Xuang
    Zhu, Xiangyu
    Lei, Zhen
    2023 IEEE/CVF CONFERENCE ON COMPUTER VISION AND PATTERN RECOGNITION (CVPR), 2023, : 8662 - 8672
  • [6] High Fidelity Image Reconstruction of Optical Sectioning Structured Illumination Microscopy
    Xie Xianfeng
    Qian Jia
    Li Xing
    Dang Shipei
    Bai Chen
    Min Junwei
    Dan Dan
    Yao Baoli
    ACTA PHOTONICA SINICA, 2023, 52 (11)
  • [7] High fidelity modeling and simulation of space net system
    高庆玉
    张青斌
    唐乾刚
    丰志伟
    Journal of Beijing Institute of Technology, 2016, 25(S2) (S2) : 64 - 67
  • [8] Deep learning reconstruction improves image quality of abdominal ultra-high-resolution CT
    Akagi, Motonori
    Nakamura, Yuko
    Higaki, Toru
    Narita, Keigo
    Honda, Yukiko
    Zhou, Jian
    Yu, Zhou
    Akino, Naruomi
    Awai, Kazuo
    EUROPEAN RADIOLOGY, 2019, 29 (11) : 6163 - 6171
  • [9] Deep learning reconstruction improves image quality of abdominal ultra-high-resolution CT
    Motonori Akagi
    Yuko Nakamura
    Toru Higaki
    Keigo Narita
    Yukiko Honda
    Jian Zhou
    Zhou Yu
    Naruomi Akino
    Kazuo Awai
    European Radiology, 2019, 29 : 6163 - 6171
  • [10] Modeling the calibration pipeline of the Lytro camera for high quality light-field image reconstruction
    Cho, Donghyeon
    Lee, Minhaeng
    Kim, Sunyeong
    Tai, Yu-Wing