Expired EBT3 Films' Sensitivity for the Measurement of X-ray and UV Radiation: An Optical Analysis

被引:2
|
作者
Abu Mhanna, Hamad Yahia [1 ]
Omar, Ahmad Fairuz [1 ]
Radzi, Yasmin Md [1 ]
Akhdar, Hanan Fawaz [2 ]
Al Ewaidat, Haytham [3 ]
机构
[1] Univ Sains Malaysia, Sch Phys, Gelugor 11800, Penang, Malaysia
[2] Imam Mohammad Ibn Saud Islamic Univ IMSIU, Phys Dept, Coll Sci, Riyadh 13318, Saudi Arabia
[3] Jordan Univ Sci & Technol, Fac Appl Med Sci, Dept Allied Med Sci Radiol Technol, Irbid 22110, Jordan
关键词
colorimetry; EBT3; expiry date; visible spectroscopy; RADIOCHROMIC FILM; GAFCHROMIC EBT3; DOSIMETRY; CALIBRATION; PROTOCOL;
D O I
10.3390/ma15082903
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
The aim of this study is to compare the optical responses of external beam therapy 3 (EBT3) films exposed to X-rays and solar ultraviolet rays (SUV-rays), as a dose control technique in the clinical sector for various radiation types, energies, and absorbed doses up to 4 Gy. In this study, EBT3 films with three different expiry dates were prepared and cut into pieces of size 2 by 2 cm(2). The first group was exposed to 90 kVp X-rays, while the second group was exposed to the SUV-rays at noon. The analysis was performed using a visible Jaz spectrometer and an EPSON Perfection V370 Photo scanner to obtain the absorbance, the net reflective optical density (ROD) and the red-green-blue (RGB) values of the samples. The results have shown that spectroscopic measurements of the exposed expired EBT3 films with these radiation sources are able to produce primary peaks and secondary peaks at lambda = 641.74 nm and lambda = 585.98 nm for X-rays, and at lambda = 637.93 nm and lambda = 584.45 nm for SUV-rays, respectively. According to these findings, compared to 2021 films that expired shortly before the trial start date; 2018 films responded better to the absorbed dose than 2016 films when exposed to both X-ray and SUV-rays. In terms of energy dependence, the expired EBT3 2018 had the largest net ROD value. Using L*a*b* indices extracted from the RGB data, and despite that EBT3 films have expiry dates according to the manufacturer; all the films exhibited a substantial colour change, indicating that these films are still usable for clinical and research purposes.
引用
收藏
页数:11
相关论文
共 50 条
  • [41] Long-term optical, UV, and X-ray continuum variations in the changing-look AGN HE 1136-2304
    Zetzl, M.
    Kollatschny, W.
    Ochmann, M. W.
    Grupe, D.
    Haas, M.
    Ramolla, M.
    Chelouche, D.
    Kaspi, S.
    Schartel, N.
    ASTRONOMY & ASTROPHYSICS, 2018, 618
  • [42] Calibration of GafChromic XR-RV3 radiochromic film for skin dose measurement using standardized x-ray spectra and a commercial flatbed scanner
    McCabe, Bradley P.
    Speidel, Michael A.
    Pike, Tina L.
    Van Lysel, Michael S.
    MEDICAL PHYSICS, 2011, 38 (04) : 1919 - 1930
  • [43] X-ray and optical stereo-based 3D sensor fusion system for image-guided neurosurgery
    Kim, Duk Nyeon
    Chae, You Seong
    Kim, Min Young
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2016, 11 (04) : 529 - 541
  • [44] Study of the Sensitivity Limit of Detection of α-Particles by Polymer Film Detectors LR-115 Type 2 Using X-ray Diffraction and UV-Vis Spectroscopic Methods
    Yerimbetova, Dana S.
    Kozlovskiy, Artem L.
    Tuichiyev, Umitali N.
    Zhumadilov, Kassym S.
    POLYMERS, 2023, 15 (11)
  • [45] Traceable Quantitative Raman Microscopy and X-ray Fluorescence Analysis as Nondestructive Methods for the Characterization of Cu(In,Ga)Se2 Absorber Films
    Zakel, Sabine
    Pollakowski, Beatrix
    Streeck, Cornelia
    Wundrack, Stefan
    Weber, Alfons
    Brunken, Stefan
    Mainz, Roland
    Beckhoff, Burckhardt
    Stosch, Rainer
    APPLIED SPECTROSCOPY, 2016, 70 (02) : 279 - 288
  • [46] X-ray diffraction measurement and equation of state for piezoelectric Pb(Zr1-xTix)O3 (x=0.1-0.8) under static compression
    Ko, Young Ho
    Kim, Kwang Joo
    Cho, Kyung Ho
    Seo, Chang Eui
    CURRENT APPLIED PHYSICS, 2011, 11 (04) : 1024 - 1030
  • [47] Is abdominal x-ray (AXR) or computed tomography (CT) of the abdomen the most appropriate imaging modality for the detection of illegal substances concealed, taking into consideration the sensitivity, specificity and radiation dose?
    Lan, Kiki
    Doyle, Edel
    JOURNAL OF FORENSIC RADIOLOGY AND IMAGING, 2019, 16 : 50 - 56
  • [48] Optical cone beam tomography of Cherenkov-mediated signals for fast 3D dosimetry of x-ray photon beams in water
    Glaser, Adam K.
    Andreozzi, Jacqueline M.
    Zhang, Rongxiao
    Pogue, Brian W.
    Gladstone, David J.
    MEDICAL PHYSICS, 2015, 42 (07) : 4127 - 4136
  • [49] Radiation Exposure of Children in Pediatric Radiology. Part 3: Conversion Coefficients for Reconstruction of Organ Doses Achieved During Chest X-ray Examinations
    Seidenbusch, M. C.
    Regulla, D.
    Schneider, K.
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2008, 180 (12): : 1061 - 1081
  • [50] Binary pseudo-random array standards for calibration of 3D optical surface profilers used for metrology with aspheric x-ray optics
    Munechika, Keiko
    Chao, Weilun
    Dhuey, Scott
    Lacey, Ian
    Pina-Hernandez, Carlos
    Rochester, Simon
    Yashchuk, Valeriy V.
    INTERFEROMETRY XXI, 2022, 12223