Multiple Open-Circuit Faults Diagnosis in Back-to-Back Converters of PMSG Drives for Wind Turbine Systems

被引:188
作者
Jlassi, Imed [1 ,2 ]
Estima, Jorge O. [2 ]
El Khil, Sejir Khojet [1 ,2 ]
Bellaaj, Najiba Mrabet [1 ]
Marques Cardoso, Antonio J. [2 ]
机构
[1] Univ Tunis El Manar, Ecole Natl Ingn Tunis, Lab Syst Elect LR11ES15, Tunis 1002, Tunisia
[2] Univ Beira Interior, Electromechatron Syst Res Ctr, P-6201001 Covilha, Portugal
关键词
Fault diagnosis in back-to-back converter; Luenberger observer; permanent magnet machines; power switch open-circuit faults; wind turbine systems; OPEN-SWITCH FAULTS; MAGNET SYNCHRONOUS MOTOR; VOLTAGE; INVERTER; SCHEME; RELIABILITY; OBSERVER;
D O I
10.1109/TPEL.2014.2342506
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In order to increase the reliability and availability of wind turbines, condition monitoring and fault diagnosis are considered crucial means to achieve these goals. In this context, direct drives wind turbines based on permanent-magnet synchronous generators (PMSGs) with full-scale power converters are an emerging and promising technology. However, several statistical studies point out that power converters are a significant contributor to the overall failure rate of modern wind turbines. Accordingly, this paper presents a new algorithm for multiple open-circuit faults diagnosis in full-scale back-to-back converters, applied in PMSG drives used for wind turbine systems. The proposed method is based on a Luenberger observer and on an adaptive threshold, which can guarantee a reliable diagnosis independently of the drive operating conditions. Several simulation and experimental results using a PMSG drive with a full-scale converter are presented, showing the diagnostic algorithm effectiveness and robustness against false alarms for both generator-and grid-side converters.
引用
收藏
页码:2689 / 2702
页数:14
相关论文
共 41 条
  • [1] Wavelet-based switching faults detection in direct torque control induction motor drives
    Aktas, M.
    Turkmenoglu, V.
    [J]. IET SCIENCE MEASUREMENT & TECHNOLOGY, 2010, 4 (06) : 303 - 310
  • [2] Hardware-circuit-based diagnosis method for open-switch faults in inverters
    An, Q. T.
    Sun, L.
    Sun, L. Z.
    [J]. ELECTRONICS LETTERS, 2013, 49 (17) : 1089 - 1090
  • [3] Low-cost diagnostic method for open-switch faults in inverters
    An, Q. T.
    Sun, L. Z.
    Sun, L.
    Jahns, T. M.
    [J]. ELECTRONICS LETTERS, 2010, 46 (14) : 1021 - U90
  • [4] Switching Function Model-Based Fast-Diagnostic Method of Open-Switch Faults in Inverters Without Sensors
    An, Qun-Tao
    Sun, Li-Zhi
    Zhao, Ke
    Sun, Li
    [J]. IEEE TRANSACTIONS ON POWER ELECTRONICS, 2011, 26 (01) : 119 - 126
  • [5] [Anonymous], 2005, P EUR C POW EL APPL
  • [6] [Anonymous], 2012, P 15 IEEE INT C EL M
  • [7] A Failure-Detection Strategy for IGBT Based on Gate-Voltage Behavior Applied to a Motor Drive System
    Antonio Rodriguez-Blanco, Marco
    Claudio-Sanchez, Abraham
    Theilliol, Didier
    Gerardo Vela-Valdes, Luis
    Sibaja-Teran, Pedro
    Hernandez-Gonzalez, Leobardo
    Aguayo-Alquicira, Jesus
    [J]. IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2011, 58 (05) : 1625 - 1633
  • [8] Future on Power Electronics for Wind Turbine Systems
    Blaabjerg, Frede
    Ma, Ke
    [J]. IEEE JOURNAL OF EMERGING AND SELECTED TOPICS IN POWER ELECTRONICS, 2013, 1 (03) : 139 - 152
  • [9] An Observer-Based Diagnosis Scheme for Single and Simultaneous Open-Switch Faults in Induction Motor Drives
    Campos-Delgado, D. U.
    Espinoza-Trejo, D. R.
    [J]. IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2011, 58 (02) : 671 - 679
  • [10] Method for Detecting an Open-Switch Fault in a Grid-Connected NPC Inverter System
    Choi, Ui-Min
    Jeong, Hae-Gwang
    Lee, Kyo-Beum
    Blaabjerg, Frede
    [J]. IEEE TRANSACTIONS ON POWER ELECTRONICS, 2012, 27 (06) : 2726 - 2739