Standardisation of a European measurement method for the determination of total gaseous mercury: results of the field trial campaign and determination of a measurement uncertainty and working range

被引:24
作者
Brown, Richard J. C. [1 ]
Pirrone, N. [2 ]
van Hoek, C. [3 ]
Sprovieri, F. [4 ]
Fernandez, R. [5 ]
Tote, K. [6 ]
机构
[1] Natl Phys Lab, Analyt Sci Team, Teddington TW11 0LW, Middx, England
[2] Inst Atmospher Pollut Res, CNR, CNR IIA, Rome, Italy
[3] Dutch Standardizat Inst, NEN, Delft, Netherlands
[4] Inst Atmospher Pollut Res, CNR, CNR IIA, Arcavacata Di Rende, Italy
[5] Inst Salud Carlos III, Madrid, Spain
[6] VMM, Flemish Environm Agcy, Antwerp, Belgium
来源
JOURNAL OF ENVIRONMENTAL MONITORING | 2010年 / 12卷 / 03期
关键词
AMBIENT AIR;
D O I
10.1039/b924955a
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Working Group 25 of the European Committee for Standardisation's (CEN) Technical Committee 264 'Air Quality' is currently finalising a standard method for the measurement of total gaseous mercury (TGM) in ambient air, in response to the requirements of the European Union's Fourth Air Quality Daughter Directive (4(th) DD). We report the results of a programme of field measurements and the statistical analysis performed to assess the uncertainty of the proposed standard method, define its working range and determine its compliance with the required data quality objectives of the Fourth Air Quality Daughter Directive. The statistical analysis has shown that the maximum relative expanded uncertainty of 50% allowed by the 4(th) DD is met down to a mercury mass concentration of approximately 0.75 ng m(-3), and that the dominant contribution to this uncertainty is systematic bias between instruments, mainly arising from the uncertainty in the calibration of the instruments.
引用
收藏
页码:689 / 695
页数:7
相关论文
共 11 条
[1]  
[Anonymous], 2008, OFF J EUR UNION, V152, P1
[2]  
Berger K, 2003, GEFAHRST REINHALT L, V63, P157
[3]   Accurate calibration of mercury vapour measurements [J].
Brown, Richard J. C. ;
Brown, Andrew S. .
ANALYST, 2008, 133 (11) :1611-1618
[4]   A practical uncertainty budget for ambient mercury vapour measurement [J].
Brown, Richard J. C. ;
Brown, Andrew S. ;
Yardley, Rachel E. ;
Corns, Warren T. ;
Stockwell, Peter B. .
ATMOSPHERIC ENVIRONMENT, 2008, 42 (10) :2504-2517
[5]   Standardisation of a European measurement method for the determination of mercury in deposition: results of the field trial campaign and determination of a measurement uncertainty and working range [J].
Brown, Richard James Christopher ;
Pirrone, N. ;
van Hoek, C. ;
Horvat, M. ;
Kotnik, J. ;
Wangberg, I. ;
Corns, W. T. ;
Bieber, E. ;
Sprovieri, F. .
ACCREDITATION AND QUALITY ASSURANCE, 2010, 15 (06) :359-366
[6]  
EU, 2005, Directive 2004/107/EC of the European Parliament and of the council of 15 December 2004 relating to arsenic, cadmium, mercury, nickel and polycyclic aromatic hydrocarbons in ambient air, VL23, P3
[7]  
*EUR COMM, 2002, AMB AIR POLL MERC HG
[8]  
*EUR COMM STAND, 2009, 158532009 FPREN CEN
[9]  
*EUR COMM STAND, 2009, 158522009 FPREN CEN
[10]  
Miller James, 2018, Statistics and chemometrics for analytical chemistry