共 47 条
Intraoperative visualization of cerebral oxygenation using hyperspectral image data: a two-dimensional mapping method
被引:36
作者:
Mori, Megumu
[1
]
Chiba, Toru
[2
]
Nakamizo, Akira
[1
]
Kumashiro, Ryuichi
[3
]
Murata, Masaharu
[4
]
Akahoshi, Tomohiko
[5
]
Tomikawa, Morimasa
[3
]
Kikkawa, Yuichiro
[1
]
Yoshimoto, Koji
[1
]
Mizoguchi, Masahiro
[1
]
Sasaki, Tomio
[1
]
Hashizume, Makoto
[5
]
机构:
[1] Kyushu Univ, Grad Sch Med Sci, Dept Neurosurg, Higashi Ku, Fukuoka 8128582, Japan
[2] HOYA Corp, PENTAX Lifecare Div Med Instrument SBU, Akishima, Tokyo 1960012, Japan
[3] Kyushu Univ Hosp, Dept Adv Med & Innovat Technol, Higashi Ku, Fukuoka 8128582, Japan
[4] Kyushu Univ, Innovat Ctr Med Redox Nav, Higashi Ku, Fukuoka 8128582, Japan
[5] Kyushu Univ, Grad Sch Med Sci, Dept Adv Med Initiat, Higashi Ku, Fukuoka 8128582, Japan
关键词:
Optical intrinsic signal image;
Visible light spectroscopy;
Oxygen saturation;
Misery perfusion;
Hyperspectral camera;
Continuous spectral data;
CORTICAL SPREADING DEPRESSION;
INDOCYANINE GREEN ANGIOGRAPHY;
BLOOD-FLOW;
OPTICAL SPECTROSCOPY;
SCATTERING CHANGES;
NEURONAL-ACTIVITY;
BYPASS;
RATS;
HEMODYNAMICS;
ISCHEMIA;
D O I:
10.1007/s11548-014-0989-9
中图分类号:
R318 [生物医学工程];
学科分类号:
0831 ;
摘要:
Superficial temporal artery (STA)-middle cerebral artery (MCA) bypass is an important technique for cerebrovascular reconstruction. Intraoperative hemodynamic imaging is needed to perform cerebrovascular reconstruction safely and effectively. Optical intrinsic signal (OIS) imaging is commonly used for assessing cerebral hemodynamics in experimental studies, because it can provide high-resolution mapping images. However, OIS is not used clinically due to algorithm, instrumentation and spectral resolution limitations. We tested the feasibility of a hyperspectral camera (HSC) for assessment of cortical hemodynamics with spectral imaging of the cerebral cortex in rats and in vivo humans. A hyperspectral camera (HSC) was tested in a rat model of cerebral ischemia (middle cerebral artery occlusion) and during human revascularization surgery (STA-MCA anastomosis). Changes in cortical oxygen saturation were derived from spectral imaging data (400-800 nm) collected by exposing the cortex to Xenon light. Reflected light was sampled using the HSC. The system was then tested intraoperatively during superficial temporal artery to middle cerebral artery anastomosis procedures. Comparison with single-photon emission computed tomography (SPECT) imaging data was done. During middle cerebral artery occlusion in rats, the HSC technique showed a significant decrease in cortical oxygen saturation in the ischemic hemisphere. In clinical cases, the cortical oxygen saturation was increased after STA-MCA anastomosis, which agreed with the SPECT imaging data. Continuous collection of imaging spectroscopic data is feasible and may provide reliable quantification of the hemodynamic responses in the brain. The HSC system may be useful for monitoring intraoperative changes in cortical surface hemodynamics during revascularization procedures in humans.
引用
收藏
页码:1059 / 1072
页数:14
相关论文