Considerations in the application of two dimensional shear wave elastography in muscle

被引:7
|
作者
Mackintosh, S. [1 ,2 ,3 ]
Young, A. [1 ]
Lee, A. [4 ]
Sim, J. [1 ,5 ]
机构
[1] Univ Auckland, Sch Med Sci, Dept Anat & Med Imaging, Auckland, New Zealand
[2] Pacific Radiol Grp, Wellington, New Zealand
[3] Pacific Radiol Grp, Manawatu, New Zealand
[4] Univ Auckland, Sch Populat Hlth, Sect Epidemiol & Biostat, Auckland, New Zealand
[5] Monash Univ, Dept Med Imaging & Radiat Sci, Sch Primary & Allied Hlth Care, Melbourne, Vic, Australia
关键词
2D-SWE; Shear wave elastography; skeletal muscle; 1 BASIC PRINCIPLES; SKELETAL-MUSCLE; ULTRASOUND ELASTOGRAPHY; CLINICAL-USE; MECHANICAL-PROPERTIES; EFSUMB GUIDELINES; WFUMB GUIDELINES; ELASTIC-MODULUS; STIFFNESS; RECOMMENDATIONS;
D O I
10.1002/sono.12204
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
There is hope that the development of 2D shear wave elastography (2D-SWE) technology will enhance clinical assessment of muscles. In addition to structural information obtained from traditional sonography, knowledge of muscle biomechanical properties may add diagnostic value in the investigation of pathological processes and functions of the musculoskeletal system. 2D-SWE offers benefits over traditional biomechanical testing tools and may be adapted to assess muscle at rest, or in contracted or lengthened states. To date, disparate research methodologies and proprietary technological differences limit comparison of research findings. Consensus guidelines exist for clinical utilisation of elastography in fields such as liver, breast and thyroid imaging. Presently, no such consensus has been reached for 2D-SWE muscle utilisation. This paper explores the current literature to describe the technical considerations and challenges of 2D-SWE in the assessment of skeletal muscle.
引用
收藏
页码:13 / 21
页数:9
相关论文
共 50 条
  • [1] Two-dimensional shear wave elastography with two different systems for the diagnosis of breast lesions
    Yu, Ji-Feng
    Zhang, Shen
    Yin, Hao-Hao
    Zhou, Bang-Guo
    Pu, Yin-Ying
    Fang, Yan
    Du, Dou
    Zhang, Yan
    Xu, Hui-Xiong
    CLINICAL HEMORHEOLOGY AND MICROCIRCULATION, 2022, 82 (01) : 53 - 62
  • [2] Feasibility and Reliability of Two-Dimensional Shear-Wave Elastography of the Liver of Clinically Healthy Cats
    Kim, Kyeonga
    Lee, Jieun
    So, Jaebeom
    Jang, Yong-seok
    Jung, Mingyu
    Kang, Kyuyong
    Choi, Mincheol
    Yoon, Junghee
    FRONTIERS IN VETERINARY SCIENCE, 2020, 7
  • [3] SYSTEMATIC REVIEW OF INSTRUMENTED MEASURES OF SKELETAL MUSCLE MECHANICAL PROPERTIES: EVIDENCE FOR THE APPLICATION OF SHEAR WAVE ELASTOGRAPHY WITH CHILDREN
    Goo, Miran
    Johnston, Leanne M.
    Hug, Francois
    Tucker, Kylie
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2020, 46 (08) : 1831 - 1840
  • [4] The application of qualitative shear wave elastography in differential diagnosis of thyroid nodules
    Liu, Qian-Qi
    Yang, Zhuo-Wen
    Tian, Jie
    Xing, Ping
    Tang, Hai-Ling
    Qiu, Qian-Yi
    Wu, Chang-Jun
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2019, 12 (04): : 3569 - 3579
  • [5] Characterization of Muscle Weakness Due to Myasthenia Gravis Using Shear Wave Elastography
    Zimmer, Manuela
    Kleiser, Benedict
    Marquetand, Justus
    Ates, Filiz
    DIAGNOSTICS, 2023, 13 (06)
  • [6] Muscle Ultrasound Shear Wave Elastography as a Non-Invasive Biomarker in Myotonia
    Kronlage, Cornelius
    Grimm, Alexander
    Romano, Alyssa
    Stahl, Jan-Hendrik
    Martin, Pascal
    Winter, Natalie
    Marquetand, Justus
    DIAGNOSTICS, 2021, 11 (02)
  • [7] Current status of musculoskeletal application of shear wave elastography
    Ryu, JeongAh
    Jeong, Woo Kyoung
    ULTRASONOGRAPHY, 2017, 36 (03) : 185 - 197
  • [8] Is musculoskeletal pain associated with increased muscle stiffness? Evidence map and critical appraisal of muscle measurements using shear wave elastography
    Haueise, Andreas
    Le Sant, Guillaume
    Eisele-Metzger, Angelika
    Dieterich, Angela V.
    CLINICAL PHYSIOLOGY AND FUNCTIONAL IMAGING, 2024, 44 (03) : 187 - 204
  • [9] Influence of transducer pressure and examiner experience on muscle active shear modulus measured by shear wave elastography
    Pimenta, R.
    Coelho, F.
    Correia, J. P.
    Vaz, J. R.
    RADIOGRAPHY, 2024, 30 (01) : 185 - 192
  • [10] Two-dimensional shear wave elastography for assessing liver, spleen, and kidneys in healthy newborns
    Postek, Grzegorz
    Zalewski, Pawel
    Sadowska-Krawczenko, Iwona
    JOURNAL OF ULTRASONOGRAPHY, 2025, 25 (100)