Swirling flow created in a glass tube suppressed platelet adhesion to the surface of the tube: Its implication in the design of small-caliber arterial grafts

被引:53
作者
Zhan, Fan [1 ]
Fan, Yubo [1 ]
Deng, Xiaoyan [1 ]
机构
[1] Beihang Univ, Sch Biol Sci & Med Engn, Beijing 100191, Peoples R China
基金
中国国家自然科学基金;
关键词
Platelet adhesion; Thrombus formation; Small-caliber arterial graft; Swirling flow; Wall shear stress; VASCULAR GRAFTS; HELICAL FLOW; BLOOD-FLOW; COLLAGEN; AGGREGATION; AORTA;
D O I
10.1016/j.thromres.2009.02.011
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
To test the hypothesis that intentionally inducing swirling blood flow in a small-caliber arterial graft can suppress acute thrombus formation by affecting the adhesion of platelets to the internal surface of the graft, an experimental comparative study was designed to investigate the effect of swirling flow on the adhesion and activation of platelets in a straight glass tube coated with calf skin type I collagen. The experimental results showed that when compared with the normal flow, the swirling flow generated in the test tube significantly reduced the platelet adhesion to the surface of the test tube. Different from normal flow condition under which platelet adhesion increased simply with decreasing wall shear stress, the platelet adhesion density under swirling flow condition remained almost unchanged along the first 5 mm section of the tube in which the flow had relatively high rotation strength, even though the wall shear stress in this section of the tube dropped drastically. This suggests that when the swirling flow in the tube was strong enough, platelet adhesion was dominantly affected by the swirling flow itself, wall shear stress was secondary. The results also showed that there was no significant difference in the activation of platelets between the spiral flow group and the normal flow group. The present study therefore suggests that intentionally introducing swirling flow in small-caliber arterial grafts has no adverse effect on platelet activation and may indeed be a solution to improving the patency of the grafts by suppressing acute thrombus formation. (C) 2009 Elsevier Ltd. All rights reserved.
引用
收藏
页码:413 / 418
页数:6
相关论文
共 26 条
[1]   MECHANICAL ISSUES IN VASCULAR GRAFTING - A REVIEW [J].
BROSSOLLET, LJ .
INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 1992, 15 (10) :579-584
[2]   Preliminary comparative study of small amplitude helical and conventional ePTFE arteriovenous shunts in pigs [J].
Caro, CG ;
Cheshire, NJ ;
Watkins, N .
JOURNAL OF THE ROYAL SOCIETY INTERFACE, 2005, 2 (03) :261-266
[3]  
FRAZIN L, 1990, CLIN RES, V38, pA331
[4]   Confirmation and initial documentation of thoracic and abdominal aortic helical flow - An ultrasound study [J].
Frazin, LJ ;
Vonesh, MJ ;
Chandran, KB ;
Shipkowitz, T ;
Yaacoub, AS ;
McPherson, DD .
ASAIO JOURNAL, 1996, 42 (06) :951-956
[5]   ADHESION OF HUMAN-PLATELETS TO COLLAGEN ON THE WALLS DISTAL TO A TUBULAR EXPANSION [J].
KARINO, T ;
GOLDSMITH, HL .
MICROVASCULAR RESEARCH, 1979, 17 (03) :238-262
[6]   FLOW PATTERNS IN VESSELS OF SIMPLE AND COMPLEX GEOMETRIES [J].
KARINO, T ;
GOLDSMITH, HL ;
MOTOMIYA, M ;
MABUCHI, S ;
SOHARA, Y .
ANNALS OF THE NEW YORK ACADEMY OF SCIENCES, 1987, 516 :422-441
[7]   HELICAL AND RETROGRADE SECONDARY FLOW PATTERNS IN THE AORTIC-ARCH STUDIED BY 3-DIRECTIONAL MAGNETIC-RESONANCE VELOCITY MAPPING [J].
KILNER, PJ ;
YANG, GZ ;
MOHIADDIN, RH ;
FIRMIN, DN ;
LONGMORE, DB .
CIRCULATION, 1993, 88 (05) :2235-2247
[8]  
Kroll MH, 1996, BLOOD, V88, P1525
[9]   Luminal surface microgeometry affects platelet adhesion in small-diameter synthetic grafts [J].
Losi, P ;
Lombardi, S ;
Briganti, E ;
Soldani, G .
BIOMATERIALS, 2004, 25 (18) :4447-4455
[10]   Requirements for growing tissue-engineered vascular grafts [J].
Mitchell, SL ;
Niklason, LE .
CARDIOVASCULAR PATHOLOGY, 2003, 12 (02) :59-64