Quantitative ultrasound image analysis of the supraspinatus muscle

被引:27
作者
Nielsen, PK [1 ]
Jensen, BR
Darvann, T
Jorgensen, K
Bakke, M
机构
[1] Natl Inst Occupat Hlth, Dept Physiol, Copenhagen, Denmark
[2] Univ Copenhagen, Sch Dent, Lab 3D, Copenhagen, Denmark
[3] Univ Copenhagen, August Krogh Inst, IESS, Dept Human Physiol, Copenhagen, Denmark
[4] Univ Copenhagen, Sch Dent, Dept Oral Funct & Physiol, Copenhagen, Denmark
关键词
shoulder; M; supraspinatus; ultrasound; image-analysis;
D O I
10.1016/S0268-0033(00)00053-X
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective. To develop and validate a method, based on quantitative ultrasound image analysis, to objectively analyse and characterize the ultrasound images of m. supraspinatus. Design. Quantitative ultrasonography was performed on the supraspinatus muscle of 14 healthy subjects. Methods.. A computerized analysis usings first-order grey-scale statistics to evaluate the muscle tissue composition was developed and validated. Results. Data from one scanning site were not representative for the whole muscle due to muscle inhomogenity. Using first-order grey-scale statistics the scanning direction was of no importance. By using a scanning session consisting of three different scanning sites along the muscle in two directions, longitudinally and transversely, to characterize the tissue composition of the muscle, a high day-to-day reproducibility was obtained. Conclusion. The described scanning session is a relatively sensitive and reproducible method for studying the muscle tissue composition.
引用
收藏
页码:S13 / S16
页数:4
相关论文
共 14 条
[1]   ULTRASONIC TISSUE CHARACTERIZATION OF SKELETAL-MUSCLE [J].
CADY, EB ;
GARDENER, JE ;
EDWARDS, RHT .
EUROPEAN JOURNAL OF CLINICAL INVESTIGATION, 1983, 13 (06) :469-473
[2]   NEUROMUSCULAR DISEASES - EVALUATION WITH HIGH-FREQUENCY SONOGRAPHY [J].
DOCK, W ;
HAPPAK, W ;
GRABENWOGER, F ;
TOIFL, K ;
BITTNER, R ;
GRUBER, H .
RADIOLOGY, 1990, 177 (03) :825-828
[3]  
Eisele R, 1998, Eur J Ultrasound, V8, P167, DOI 10.1016/S0929-8266(98)00073-1
[4]   REAL-TIME ULTRASOUND IMAGING OF MUSCLES [J].
HECKMATT, JZ ;
PIER, N ;
DUBOWITZ, V .
MUSCLE & NERVE, 1988, 11 (01) :56-65
[5]   THE EFFECT OF PROLONGED ISOMETRIC CONTRACTIONS ON MUSCLE FLUID BALANCE [J].
JENSEN, BR ;
JORGENSEN, K ;
SJOGAARD, G .
EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 1994, 69 (05) :439-444
[6]  
JENSEN BR, 1995, EUR J MORPHOL, V33, P205
[7]  
JENSEN BR, 1998, PROLONGED WORK SHOUL, P149
[8]   ULTRASOUND IMAGING OF THE MASSETER MUSCLE IN MYOTONIC-DYSTROPHY PATIENTS [J].
KILIARIDIS, S ;
ENGVALL, M ;
TZAKIS, MG .
JOURNAL OF ORAL REHABILITATION, 1995, 22 (08) :619-625
[9]  
LAMMINEN A, 1988, J ULTRAS MED, V7, P505
[10]   MUSCLE STRENGTH AND HISTORY OF HEAVY MANUAL WORK AMONG ELDERLY TRAINED WOMEN AND RANDOMLY CHOSEN SAMPLE-POPULATION [J].
RANTANEN, T ;
SIPILA, S ;
SUOMINEN, H .
EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY AND OCCUPATIONAL PHYSIOLOGY, 1993, 66 (06) :514-517