Bronchial Segment Matching in Low-dose Lung CT Scan Pairs

被引:0
|
作者
Lee, Jaesung [1 ]
Reeves, Anthony P. [1 ]
Yankelevitz, David F. [2 ]
Henschke, Claudia, I [2 ]
机构
[1] Cornell Univ, Sch Elect & Comp Engn, Ithaca, NY 14850 USA
[2] Weill Cornell Med Coll, Dept Radiol, New York, NY USA
来源
MEDICAL IMAGING 2009: COMPUTER-AIDED DIAGNOSIS | 2009年 / 7260卷
关键词
Lung; CT; airway; bronchial segment; IMAGE REGISTRATION;
D O I
10.1117/12.812024
中图分类号
TP301 [理论、方法];
学科分类号
081202 ;
摘要
Documenting any change in airway dimensions over time may be relevant for monitoring the progression of pulmonary diseases. In order to correctly measure the change in segmental dimensions of airways, it is necessary to locate the identical airway segments across two scans. In this paper, we present an automated method to match individual bronchial segments from a pair of low-dose CT scans. Our method uses the intensity information in addition to the graph structure as evidences for matching the individual segments. 3D image correlation matching technique is employed to match the region of interest around the branch points in two scans and therefore locate the matching bronchial segments. The matching process was designed to address the differences in airway tree structures from two scans due to the variation in tree segmentations. The algorithm was evaluated using 114 pairs of low-dose CT scans (120 kV, 40 mAs). The total number of segments matched was 3591, of which 99.7% were correctly matched. When the matching was limited to the bronchial segments of the fourth generation or less, the algorithm correctly identified all of 1553 matched segments.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] LOW-DOSE HIGH-RESOLUTION CT OF LUNG PARENCHYMA
    ZWIREWICH, CV
    MAYO, JR
    MULLER, NL
    RADIOLOGY, 1991, 180 (02) : 413 - 417
  • [2] SCREENING FOR LUNG CANCER WITH LOW-DOSE CT
    Coche, E.
    JBR-BTR, 2008, 91 (01): : 1 - 5
  • [3] Lung cancer screening with low-dose CT
    Diederich, S
    Wormanns, D
    Heindel, W
    EUROPEAN JOURNAL OF RADIOLOGY, 2003, 45 (01) : 2 - 7
  • [4] Automated lung nodule detection at low-dose CT: Preliminary experience
    Goo, JM
    Lee, JW
    Lee, HJ
    Kim, S
    Kim, JH
    Im, JG
    KOREAN JOURNAL OF RADIOLOGY, 2003, 4 (04) : 211 - 216
  • [5] Development and Validation of Automated 2D-3D Bronchial Airway Matching to Track Changes in Regional Bronchial Morphology Using Serial Low-Dose Chest CT Scans in Children with Chronic Lung Disease
    Raman, Pavithra
    Raman, Raghav
    Newman, Beverley
    Venkatraman, Raman
    Raman, Bhargav
    Robinson, Terry E.
    JOURNAL OF DIGITAL IMAGING, 2010, 23 (06) : 744 - 754
  • [6] Development and Validation of Automated 2D–3D Bronchial Airway Matching to Track Changes in Regional Bronchial Morphology Using Serial Low-Dose Chest CT Scans in Children with Chronic Lung Disease
    Pavithra Raman
    Raghav Raman
    Beverley Newman
    Raman Venkatraman
    Bhargav Raman
    Terry E. Robinson
    Journal of Digital Imaging, 2010, 23 : 744 - 754
  • [7] Low-dose CT: new tool for screening lung cancer?
    Diederich, S
    Wormanns, D
    Heindel, W
    EUROPEAN RADIOLOGY, 2001, 11 (10) : 1916 - 1924
  • [8] Low-dose CT of the lung: potential value of iterative reconstructions
    Stephan Baumueller
    Anna Winklehner
    Christoph Karlo
    Robert Goetti
    Thomas Flohr
    Erich W. Russi
    Thomas Frauenfelder
    Hatem Alkadhi
    European Radiology, 2012, 22 : 2597 - 2606
  • [9] Low-dose lung CT: Optimizing diagnostic radiation dose - A phantom study
    Zellner, Michael
    Tschauner, Sebastian
    Weyland, Mathias S.
    Hotz, Peter Eggenberger
    Scheidegger, Stephan
    Kellenberger, Christian J.
    EUROPEAN JOURNAL OF RADIOLOGY OPEN, 2024, 13
  • [10] Low-dose CT of the lung: potential value of iterative reconstructions
    Baumueller, Stephan
    Winklehner, Anna
    Karlo, Christoph
    Goetti, Robert
    Flohr, Thomas
    Russi, Erich W.
    Frauenfelder, Thomas
    Alkadhi, Hatem
    EUROPEAN RADIOLOGY, 2012, 22 (12) : 2597 - 2606