Utilization of W/Mg(NO3)2 modifiers for the direct determination of As and Sb in soils, sewage sludge and sediments by solid sampling electrothermal atomic absorption spectrometry

被引:18
作者
Torok, Peter [1 ]
Zemberyova, Maria [1 ]
机构
[1] Comenius Univ, Fac Nat Sci, Dept Analyt Chem, Bratislava 84215, Slovakia
关键词
Arsenic; Antimony; Soil; Sewage sludge; Sediment; GRAPHITE-FURNACE; HYDRIDE GENERATION; ANTIMONY DETERMINATION; ARSENIC DETERMINATION; CHEMICAL MODIFIERS; FEASIBILITY; EXTRACTION; PALLADIUM; ETAAS; LEAD;
D O I
10.1016/j.sab.2010.03.007
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
A simple method has been developed for the determination of arsenic and antimony in environmental samples by solid sampling electrothermal atomic absorption spectrometry, which was validated using certified reference materials of soils (S-VM Soil Eutric Cambisol; S-MS Soil Orthic Luvisols; S-SP Soil Rendzina), sewage sludge (WT-L; WT-M) and sediments (NIES2; GBW07906). The analytical procedure combines solid sampling with utilization of a matrix modifier admixture containing 5 mu g of W and 5 mu g of Mg. The tungsten in the admixture serves to stabilize the solid matrix during atomisation, which results in dramatically reduced non-specific absorption compared with the conventional palladium modifier. Magnesium was efficient in reducing the accumulation of the matrix residue on the platform. An alternative resonance line of 197.2 nm for arsenic and 206.8 nm for Sb was used in order to eliminate the spectral interferences caused by aluminum compounds, and silicon and iron compounds, respectively. Under optimized experimental conditions, the effective in situ analyte/matrix separation was achieved so that the use of aqueous standards for calibration became possible. With the modifier, a 3 SD detection limit of 0.5 mu g g(-1) As and 0.1 mu g g(-1) Sb and 10 SD quantification limit of 1.7 mu g g(-1) As and 0.3 mu g g(-1) Sb and a characteristic mass of 65 pg As and 53 pg Sb were obtained. For all the matrices under scrutiny, a good agreement with certified values was achieved with RSD values less than 10%. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:291 / 296
页数:6
相关论文
共 39 条
[1]   Correction of structured molecular background by means of high-resolution continuum source electrothermal atomic absorption spectrometry-Determination of antimony in sediment reference materials using direct solid sampling [J].
Araujo, Rennan G. O. ;
Welz, Bernhard ;
Vignola, Fabiola ;
Becker-Ross, Helmut .
TALANTA, 2009, 80 (02) :846-852
[2]   Determination of arsenic in sediment and soil slurries by electrothermal atomic absorption spectrometry using W-Rh permanent modifier [J].
Barbosa, F ;
Lima, ÉC ;
Krug, FJ .
ANALYST, 2000, 125 (11) :2079-2083
[3]  
Barciela-Alonso MC, 2007, ATOM SPECTROSC, V28, P102
[4]  
BECCALONI E, 2002, ANAL BIOANAL CHEM, V374, P1230
[5]   Direct determination of cobalt and zinc in samples of different volatility by means of solid sampling-graphite furnace atomic absorption spectrometry [J].
Belarra, MA ;
Crespo, C ;
Martínez-Garbayo, MR ;
Resano, M .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2003, 58 (10) :1847-1858
[6]   Direct determination of copper and lead in sewage sludge by solid sampling-graphite furnace atomic absorption spectrometry - study of the interference reduction in the gaseous phase working in non-stop flow conditions [J].
Belarra, MA ;
Crespo, C ;
Resano, M ;
Castillo, JR .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2000, 55 (07) :865-874
[7]   THE INFLUENCE OF PYROLYSIS AND MATRIX MODIFIERS FOR ANALYSIS OF GLASS MATERIALS BY GFAAS USING SLURRY SAMPLE INTRODUCTION [J].
BENDICHO, C ;
DELOOSVOLLEBREGT, MTC .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1990, 45 (07) :679-693
[8]  
Cal-Prieto MJ, 2000, ATOM SPECTROSC, V21, P93
[9]   Development of an analytical scheme for the direct determination of antimony in geological materials by automated ultrasonic slurry sampling-ETAAS [J].
Cal-Prieto, MJ ;
Carlosena, A ;
Andrade, JM ;
Muniategui, S ;
López-Mahía, P ;
Fernández, E ;
Prada, D .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1999, 14 (04) :703-710
[10]   Tube ageing as an important quality factor in the direct determination of Sb in solid samples by ultrasonic slurry sampling-GFAAS [J].
Cal-Prieto, MJ ;
Carlosena, A ;
Andrade, JM ;
López-Mahía, P ;
Muniategui, S ;
Prada, D .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2003, 18 (01) :29-37