Quantification of functional mitral valve regurgitation in patients with congestive heart failure: Comparison of electron-beam computed tomography with cardiac catheterization

被引:9
作者
Lembcke, A
Borges, AC
Dohmen, PM
Hoffmann, U
Hermann, KGA
Kroencke, TJ
Fischer, T
Hamm, B
Enzweiler, CNH
机构
[1] Harvard Univ, Massachusetts Gen Hosp, Sch Med, Dept Radiol, Boston, MA 02114 USA
[2] Univ Med Berlin, Charite Med Sch, Dept Radiol, Berlin, Germany
[3] Univ Med Berlin, Charite Med Sch, Dept Internal Med 1, Cardiol Angiol & Pulm Sect, Berlin, Germany
[4] Univ Med Berlin, Charite Med Sch, Dept Cardiovasc Surg, Berlin, Germany
关键词
computed tomography (CT); electron beam; catheters and catheterization; echocardiography; heart; mitral valve; regurgitation;
D O I
10.1097/00004424-200412000-00004
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives: We sought to determine the agreement between electron-beam computed tomography (CT) and cardiac catheterization for the quantification of mitral regurgitation and to evaluate their association with echocardiographic assessment. Material and Methods: Fifty patients with congestive heart failure were examined both by electron-beam CT and catheterization to calculate mitral regurgitation volume and fraction based on the difference between the left ventricular stroke and aortic flow volume. The severity of regurgitation was also compared with visual assessment by echocardiography (grade, 0-4+). Results: The mean values for the mitral regurgitation volume and fraction did not differ significantly between electron-beam CT and catheterization (mean differences: 0.2 mL/m(2) and -0.9%, P > 0.05 each, limits of agreement: -14.0 to 14.4 mL/m(2) and -26.3 to 24.5%, respectively) and showed a good correlation (r = 0.79 and r = 0.76, respectively; P < 0.05 each). Good levels of correlation were observed between echocardiographic severity grading and quantitative measurements of regurgitation volume and fraction, which were somewhat better between echocardiography and electron-beam CT (r(S) = 0.78 and r(S) = 0.84, respectively; P < 0.05 each) than between echocardiography and catheterization (r(S) = 0.72 and r(S) = 0.81, respectively; P < 0.05 each). Conclusion: Our results suggest that electron-beam CT allows for quantification of mitral valve regurgitation with similar accuracy as cardiac catheterization. Measurements with both modalities correlated well with the results of echocardiographic assessment.
引用
收藏
页码:728 / 739
页数:12
相关论文
共 47 条
[11]   THE USE OF BIPLANE ANGIOCARDIOGRAPHY FOR THE MEASUREMENT OF LEFT VENTRICULAR VOLUME IN MAN [J].
DODGE, HT ;
SANDLER, H ;
BALLEW, DW ;
LORD, JD .
AMERICAN HEART JOURNAL, 1960, 60 (05) :762-776
[12]   Is the indicator dilution theory really the adequate base of many blood flow measurement techniques? [J].
Doriot, PA ;
Dorsaz, PA ;
Dorsaz, L ;
Rutishauser, WJ .
MEDICAL PHYSICS, 1997, 24 (12) :1889-1898
[13]  
ENZWEILER CN, 2004, ROFO FORTSCHR RONTG, V175, P27
[14]   MEASUREMENT OF CARDIAC-OUTPUT BY CINE COMPUTED-TOMOGRAPHY [J].
GARRETT, JS ;
LANZER, P ;
JASCHKE, W ;
BOTVINICK, E ;
SIEVERS, R ;
HIGGINS, CB ;
LIPTON, MJ .
AMERICAN JOURNAL OF CARDIOLOGY, 1985, 56 (10) :657-661
[15]  
Grossman W, 1980, CARDIAC CATHETERIZAT, P305
[16]   Evaluation of global left ventricular myocardial function with electrocardiogram-gated multidetector computed tomography - Comparison with magnetic resonance imaging [J].
Grude, M ;
Juergens, KU ;
Wichter, T ;
Paul, M ;
Fallenberg, EM ;
Muller, JG ;
Heindel, W ;
Breithardt, G ;
Fischbach, R .
INVESTIGATIVE RADIOLOGY, 2003, 38 (10) :653-661
[17]   COMPARISON OF THERMODILUTION AND INDOCYANINE GREEN-DYE IN LOW CARDIAC-OUTPUT OR LEFT-SIDED REGURGITATION [J].
HILLIS, LD ;
FIRTH, BG ;
WINNIFORD, MD .
AMERICAN JOURNAL OF CARDIOLOGY, 1986, 57 (13) :1201-1202
[18]   MAGNETIC-RESONANCE-IMAGING ASSESSMENT OF THE SEVERITY OF MITRAL REGURGITATION - COMPARISON WITH INVASIVE TECHNIQUES [J].
HUNDLEY, WG ;
LI, HF ;
WILLARD, JE ;
LANDAU, C ;
LANGE, RA ;
MESHACK, BM ;
HILLIS, LD ;
PESHOCK, RM .
CIRCULATION, 1995, 92 (05) :1151-1158
[19]   FLOW MEASUREMENTS WITH A HIGH-SPEED COMPUTED-TOMOGRAPHY SCANNER [J].
JASCHKE, W ;
GOULD, RG ;
ASSIMAKOPOULOS, PA ;
LIPTON, MJ .
MEDICAL PHYSICS, 1987, 14 (02) :238-243
[20]   QUANTITATIVE-EVALUATION OF MITRAL REGURGITATION WITH ULTRAFAST CT [J].
KAMINAGA, T ;
NAITO, H ;
TAKAMIYA, M ;
NISHIMURA, T .