Quantification of functional mitral valve regurgitation in patients with congestive heart failure: Comparison of electron-beam computed tomography with cardiac catheterization

被引:9
作者
Lembcke, A
Borges, AC
Dohmen, PM
Hoffmann, U
Hermann, KGA
Kroencke, TJ
Fischer, T
Hamm, B
Enzweiler, CNH
机构
[1] Harvard Univ, Massachusetts Gen Hosp, Sch Med, Dept Radiol, Boston, MA 02114 USA
[2] Univ Med Berlin, Charite Med Sch, Dept Radiol, Berlin, Germany
[3] Univ Med Berlin, Charite Med Sch, Dept Internal Med 1, Cardiol Angiol & Pulm Sect, Berlin, Germany
[4] Univ Med Berlin, Charite Med Sch, Dept Cardiovasc Surg, Berlin, Germany
关键词
computed tomography (CT); electron beam; catheters and catheterization; echocardiography; heart; mitral valve; regurgitation;
D O I
10.1097/00004424-200412000-00004
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives: We sought to determine the agreement between electron-beam computed tomography (CT) and cardiac catheterization for the quantification of mitral regurgitation and to evaluate their association with echocardiographic assessment. Material and Methods: Fifty patients with congestive heart failure were examined both by electron-beam CT and catheterization to calculate mitral regurgitation volume and fraction based on the difference between the left ventricular stroke and aortic flow volume. The severity of regurgitation was also compared with visual assessment by echocardiography (grade, 0-4+). Results: The mean values for the mitral regurgitation volume and fraction did not differ significantly between electron-beam CT and catheterization (mean differences: 0.2 mL/m(2) and -0.9%, P > 0.05 each, limits of agreement: -14.0 to 14.4 mL/m(2) and -26.3 to 24.5%, respectively) and showed a good correlation (r = 0.79 and r = 0.76, respectively; P < 0.05 each). Good levels of correlation were observed between echocardiographic severity grading and quantitative measurements of regurgitation volume and fraction, which were somewhat better between echocardiography and electron-beam CT (r(S) = 0.78 and r(S) = 0.84, respectively; P < 0.05 each) than between echocardiography and catheterization (r(S) = 0.72 and r(S) = 0.81, respectively; P < 0.05 each). Conclusion: Our results suggest that electron-beam CT allows for quantification of mitral valve regurgitation with similar accuracy as cardiac catheterization. Measurements with both modalities correlated well with the results of echocardiographic assessment.
引用
收藏
页码:728 / 739
页数:12
相关论文
共 47 条
[1]   Comparison of image quality in contrast-enhanced coronary artery visualization by electron beam tomography and retrospectively electrocardiogram-gated multislice spiral computed tomography [J].
Achenbach, S ;
Giesler, T ;
Ropers, D ;
Ulzheimer, S ;
Anders, K ;
Wenkel, E ;
Pohle, K ;
Kachelriess, M ;
Derlien, H ;
Kalender, WA ;
Daniel, WG ;
Bautz, W ;
Baum, U .
INVESTIGATIVE RADIOLOGY, 2003, 38 (02) :119-128
[2]   Accurate measures of left ventricular ejection fraction using electron beam tomography: A comparison with radionuclide angiography, and cine angiography [J].
Baik, HK ;
Budoff, MJ ;
Lane, KL ;
Bakhsheshi, H ;
Brundage, BH .
INTERNATIONAL JOURNAL OF CARDIAC IMAGING, 2000, 16 (05) :391-398
[3]  
Becker C, 1999, ROFO-FORTSCHR RONTG, V170, P99
[4]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[5]   QUANTIFYING VALVULAR REGURGITATION - LIMITATIONS AND INHERENT ASSUMPTIONS OF DOPPLER TECHNIQUES [J].
BOLGER, AF ;
EIGLER, NL ;
MAURER, G .
CIRCULATION, 1988, 78 (05) :1316-1318
[6]   COMPARISON OF SINGLE AND BIPLANE VENTRICULOGRAPHY FOR DETERMINATION OF LEFT-VENTRICULAR VOLUME AND EJECTION FRACTION [J].
BROGAN, WC ;
GLAMANN, DB ;
LANGE, RA ;
HILLIS, LD .
AMERICAN JOURNAL OF CARDIOLOGY, 1992, 69 (12) :1079-1082
[7]  
Carabello B A, 1995, J Heart Valve Dis, V4 Suppl 2, pS132
[8]   LIMITATIONS OF QUALITATIVE ANGIOGRAPHIC GRADING IN AORTIC OR MITRAL REGURGITATION [J].
CROFT, CH ;
LIPSCOMB, K ;
MATHIS, K ;
FIRTH, BG ;
NICOD, P ;
TILTON, G ;
WINNIFORD, MD ;
HILLIS, LD .
AMERICAN JOURNAL OF CARDIOLOGY, 1984, 53 (11) :1593-1598
[9]  
DEBONO D, 1993, BRIT HEART J, V70, P297
[10]   Multisegment and halfscan reconstruction of 16-slice computed tomography for detection of coronary artery stenoses [J].
Dewey, M ;
Laule, M ;
Krug, L ;
Schnapauff, D ;
Rogalla, P ;
Rutsch, WF ;
Hamm, B ;
Lembcke, A .
INVESTIGATIVE RADIOLOGY, 2004, 39 (04) :223-229