The effect of in situ/in vitro three-dimensional quantitative computed tomography image voxel size on the finite element model of human vertebral cancellous bone
Quantitative computed tomography image;
finite element;
voxel size;
in situ;
in vitro;
vertebra;
3D QCT;
CT;
STRENGTH;
MICROMECHANICS;
ALENDRONATE;
WOMEN;
ELASTICITY;
FRACTURES;
PROTOCOL;
D O I:
10.1177/0954411914558654
中图分类号:
R318 [生物医学工程];
学科分类号:
0831 ;
摘要:
Quantitative computed tomography-based finite element modeling technique is a promising clinical tool for the prediction of bone strength. However, quantitative computed tomography-based finite element models were created from image datasets with different image voxel sizes. The aim of this study was to investigate whether there is an influence of image voxel size on the finite element models. In all 12 thoracolumbar vertebrae were scanned prior to autopsy (in situ) using two different quantitative computed tomography scan protocols, which resulted in image datasets with two different voxel sizes (0.29x0.29x1.3mm(3) vs 0.18x0.18x0.6mm(3)). Eight of them were scanned after autopsy (in vitro) and the datasets were reconstructed with two voxel sizes (0.32x0.32x0.6mm(3) vs. 0.18x0.18x0.3mm(3)). Finite element models with cuboid volume of interest extracted from the vertebral cancellous part were created and inhomogeneous bilinear bone properties were defined. Axial compression was simulated. No effect of voxel size was detected on the apparent bone mineral density for both the in situ and in vitro cases. However, the apparent modulus and yield strength showed significant differences in the two voxel size group pairs (in situ and in vitro). In conclusion, the image voxel size may have to be considered when the finite element voxel modeling technique is used in clinical applications.
引用
收藏
页码:1208 / 1213
页数:6
相关论文
共 28 条
[1]
[Anonymous], 2009, FUNDAMENTALS MED IMA, DOI DOI 10.1017/CBO9780511596803
机构:
Charles Univ Prague, Dept Anat, Fac Med 3, Prague, Czech RepublicCharles Univ Prague, Dept Anat, Fac Med 3, Prague, Czech Republic
Baca, Vaclav
Horak, Zdenek
论文数: 0引用数: 0
h-index: 0
机构:
Czech Tech Univ, Fac Mech Engn, Biomech Lab, CR-16635 Prague, Czech RepublicCharles Univ Prague, Dept Anat, Fac Med 3, Prague, Czech Republic
Horak, Zdenek
Mikulenka, Petr
论文数: 0引用数: 0
h-index: 0
机构:
Czech Tech Univ, Fac Mech Engn, Biomech Lab, CR-16635 Prague, Czech RepublicCharles Univ Prague, Dept Anat, Fac Med 3, Prague, Czech Republic
Mikulenka, Petr
Dzupa, Valer
论文数: 0引用数: 0
h-index: 0
机构:
Charles Univ Prague, Dept Orthopaed & Traumatol, Fac Med 3, Prague, Czech RepublicCharles Univ Prague, Dept Anat, Fac Med 3, Prague, Czech Republic
机构:
Charles Univ Prague, Dept Anat, Fac Med 3, Prague, Czech RepublicCharles Univ Prague, Dept Anat, Fac Med 3, Prague, Czech Republic
Baca, Vaclav
Horak, Zdenek
论文数: 0引用数: 0
h-index: 0
机构:
Czech Tech Univ, Fac Mech Engn, Biomech Lab, CR-16635 Prague, Czech RepublicCharles Univ Prague, Dept Anat, Fac Med 3, Prague, Czech Republic
Horak, Zdenek
Mikulenka, Petr
论文数: 0引用数: 0
h-index: 0
机构:
Czech Tech Univ, Fac Mech Engn, Biomech Lab, CR-16635 Prague, Czech RepublicCharles Univ Prague, Dept Anat, Fac Med 3, Prague, Czech Republic
Mikulenka, Petr
Dzupa, Valer
论文数: 0引用数: 0
h-index: 0
机构:
Charles Univ Prague, Dept Orthopaed & Traumatol, Fac Med 3, Prague, Czech RepublicCharles Univ Prague, Dept Anat, Fac Med 3, Prague, Czech Republic