The role of welding techniques in the biomechanical behavior of implant-supported prostheses

被引:13
|
作者
Rodrigues, Sabrina Alessandra [1 ]
Camacho Presotto, Anna Gabriella [1 ]
Ricardo Barao, Valentim Adelino [1 ]
Xediek Consani, Rafael Leonardo [1 ]
Arruda Nobilo, Mauro Antonio [1 ]
Mesquita, Marcelo Ferraz [1 ]
机构
[1] Univ Estadual Campinas, Piracicaba Dent Sch, Dept Prosthodont & Periodontol, Piracicaba, Brazil
基金
巴西圣保罗研究基金会;
关键词
Prostheses and implants; Welding; Dental marginal adaptation; Imaging; Three-dimensional; Dental stress analysis; TITANIUM FRAMEWORKS; VERTICAL MISFIT; FIT; ALLOY; LASER; FABRICATION; STRENGTH; CAD/CAM; SCREWS; JOINT;
D O I
10.1016/j.msec.2017.04.090
中图分类号
TB3 [工程材料学]; R318.08 [生物材料学];
学科分类号
0805 ; 080501 ; 080502 ;
摘要
This in vitro study investigated the role of welding techniques of implant-supported prostheses in the 2D and 3D marginal misfits of prosthetic frameworks, strain induced on the mini abutment, and detorque of prosthetic screws. The correlations between the analyzed variables were also investigated. Frameworks were cast in commercially pure titanium (cp-Ti). A marginal misfit of 200 mu m was simulated in the working models (control group) (n = 20). The 2D marginal misfit was analyzed according to the single-screw test protocol using a precision optical microscope. The 3D marginal misfit was performed by X-ray microtomography. Strain gauge analysis was performed to investigate the strain induced on the mini abutment. A digital torque meter was used for analysis of the detorque and the mean value was calculated for each framework. Afterwards, the frameworks were divided into two experimental groups (n = 10): Laser (L) and TIG (T). The welding techniques were performed according to the following parameters: L (390 V/9 ms); T (36 A/60 ms). The L and T groups were reevaluated according to the marginal misfit, strain, and detorque. The results were submitted to one-way ANOVA followed by Tukey's HSD test and Person correlation analysis (alpha = 0.05). Welding techniques statistically reduced the 2D and 3D marginal misfits of prosthetic frameworks (p < 0.001), the strain induced on the mini abutment replicas (p = 0.006), and improved the screw torque maintenance (p < 0.001). Similar behavior was noted between L and T groups for all dependent variables (p > 0.05). Positive correlations were observed between 2D and 3D marginal misfit reading methods (r = 0.943, p < 0.0001) and between misfit and strain (2D r = 0.844, p < 0.0001 and 3D r = 0.864, p < 0.0001). Negative correlation was observed between misfit and detorque (2D r = -0.823, p = 0.003 and 3D r = -0.811, p = 0.005). In conclusion, the welding techniques improved the biomechanical behavior of the implant-supported system. TIG can be an acceptable and affordable technique to reduce the misfit of 3 unit Ti frameworks. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:435 / 442
页数:8
相关论文
共 50 条
  • [31] Completely implant-supported telescopic maxillofacial prostheses.
    Weischer, T
    Mohr, C
    JOURNAL OF DENTAL RESEARCH, 2000, 79 : 296 - 296
  • [32] Cement retention for retrievable implant-supported prostheses.
    Alfaro, MA
    Papazoglou, E
    Beck, M
    McGlumphy, EA
    Holloway, JA
    JOURNAL OF DENTAL RESEARCH, 2000, 79 : 530 - 530
  • [33] Implant-supported fixed and removable prostheses in the fibular mandible
    Nguyen, Truc Thi Hoang
    Eo, Mi Young
    Myoung, Hoon
    Kim, Myung-Joo
    Kim, Soung Min
    INTERNATIONAL JOURNAL OF IMPLANT DENTISTRY, 2020, 6 (01)
  • [34] Study of occlusal patterns in completely implant-supported prostheses
    Tortamano, P
    Saito, T
    Boruszewski, W
    JOURNAL OF DENTAL RESEARCH, 1998, 77 (05) : 1180 - 1180
  • [35] Implant-supported fixed and removable prostheses in the fibular mandible
    Truc Thi Hoang Nguyen
    Mi Young Eo
    Hoon Myoung
    Myung-Joo Kim
    Soung Min Kim
    International Journal of Implant Dentistry, 6
  • [36] Influence of the frameworks of implant-supported prostheses and implant connections on stress distribution
    Tonin, Bruna Santos Honorio
    Peixoto, Raniel Fernandes
    Fu, Jing
    de Mattos, Maria da Gloria Chiarello
    Macedo, Ana Paula
    DENTAL AND MEDICAL PROBLEMS, 2023, 60 (04) : 551 - 557
  • [37] Removable dentures versus implant-supported prostheses in the elderly
    Bortolotti, L.
    DENTAL CADMOS, 2011, 79 (01) : 18 - 26
  • [38] Facial defects restored with extraoral implant-supported prostheses
    Karayazgan, Banu
    Gunay, Yumushan
    Atay, Arzu
    Noyun, Fuat
    JOURNAL OF CRANIOFACIAL SURGERY, 2007, 18 (05) : 1086 - 1090
  • [39] Photoelastic Analysis of Cemented or Screwed Implant-Supported Prostheses With Different Prostheses Connections
    Tonella, Bianca Piccolotto
    Pellizzer, Eduardo Piza
    Ferraco, Renato
    Falcon-Antenucci, Rosse Mary
    Perri de Carvalho, Paulo S.
    Goiato, Marcelo Coelho
    JOURNAL OF ORAL IMPLANTOLOGY, 2011, 37 (04) : 401 - 410
  • [40] Comparison of fixed implant-supported prostheses, removable implant-supported prostheses, and complete dentures: patient satisfaction and oral health-related quality of life
    Oh, Sung-Hee
    Kim, Younhee
    Park, Joo-Yeon
    Jung, Yea Ji
    Kim, Seong-Kyun
    Park, Sun-Young
    CLINICAL ORAL IMPLANTS RESEARCH, 2016, 27 (02) : E31 - E37