Evaluation of a proper cutoff value on quantitative dual-energy perfusion CT for the assessment of acute pulmonary thromboembolism

被引:2
作者
Kunihiro, Yoshie [1 ]
Okada, Munemasa [1 ]
Matsunaga, Naofumi [1 ]
机构
[1] Yamaguchi Univ, Grad Sch Med, Dept Radiol, 1-1-1 Minamikogushi, Ube, Yamaguchi 7558505, Japan
关键词
Dual-energy; volumetric; computed tomography (CT); pulmonary embolism; qualitative evaluation; HELICAL CT; EMBOLISM; ANGIOGRAPHY; OBSTRUCTION; QUANTIFICATION; PREDICTION; SEVERITY; INDEX;
D O I
10.1177/0284185116683577
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: The cutoff value for assessing the severity of acute pulmonary thromboembolism (PTE) using relative volumetric evaluations of dual-energy perfusion computed tomography (DEpCT) is unclear. Purpose: To determine the proper cutoff value for determining the severity of PTE using DEpCT volumetry. Material and Methods: A total of 185 patients with venous thromboembolism were included in this study, of whom 61 were diagnosed with acute PTE. DEpCT images were three-dimensionally reconstructed at the following attenuation ranges: 1-2 HU (V2), 1-10 HU (V10), and 1-120 HU (V120). The ratios of low perfusion areas associated with each threshold range per V120 were also calculated, and the relative ratios were expressed as % V2 to % V10. These values were compared with factors indicating the severity of PTE, including the pulmonary arterial pressure, heart rate, CT angiographic obstruction index (CTOI), and right/left ventricular diameter ratio (RV/LV). Results: The area under the curve (AUC) of % V2 was highest (0.783) among these values (95% confidence interval, 0.710-0.856) based on the presence of IPCs. The % V2 showed moderate correlations with CTOI (r = 0.36, P = 0.005) and RV/LV (r = 0.36, P = 0.004) in the patients with acute PTE. Conclusion: Volumetric evaluations of DEpCT images using the lowest attenuation threshold range (1-2 HU) exhibit the best correlation with factors suggesting the severity of acute PTE.
引用
收藏
页码:1061 / 1067
页数:7
相关论文
共 18 条
[1]   Comparison of ventilation/perfusion scintigraphy and helical CT for diagnosis of pulmonary embolism; strategy using clinical data and ancillary findings [J].
Bajc, M ;
Albrechtsson, U ;
Olsson, CG ;
Olsson, B ;
Jonson, B .
CLINICAL PHYSIOLOGY AND FUNCTIONAL IMAGING, 2002, 22 (06) :392-397
[2]   Dose and image quality at CT pulmonary angiography-comparison of first and second generation dual-energy CT and 64-slice CT [J].
Bauer, Ralf W. ;
Kramer, Sebastian ;
Renker, Matthias ;
Schell, Boris ;
Larson, Maya Christina ;
Beeres, Martin ;
Lehnert, Thomas ;
Jacobi, Volkmar ;
Vogl, Thomas J. ;
Kerl, Josef Matthias .
EUROPEAN RADIOLOGY, 2011, 21 (10) :2139-2147
[3]   Dual-Energy CT for Assessment of the Severity of Acute Pulmonary Embolism: Pulmonary Perfusion Defect Score Compared With CT Angiographic Obstruction Score and Right Ventricular/Left Ventricular Diameter Ratio [J].
Chae, Eun Jin ;
Seo, Joon Beom ;
Jang, Yu Mi ;
Krauss, Bernhard ;
Lee, Choong Wook ;
Lee, Hyun Joo ;
Song, Koun-Sik .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 194 (03) :604-610
[4]   Severity assessment of acute pulmonary embolism: evaluation using helical CT [J].
Collomb, D ;
Paramelle, PJ ;
Calaque, O ;
Bosson, JL ;
Vanzetto, G ;
Barnoud, D ;
Pison, C ;
Coulomb, M ;
Ferretti, G .
EUROPEAN RADIOLOGY, 2003, 13 (07) :1508-1514
[5]   Severe pulmonary embolism: Pulmonary artery clot load scores and cardiovascular parameters as predictors of mortality [J].
Ghaye, B ;
Ghuysen, A ;
Willems, V ;
Lambermont, B ;
Gerard, P ;
D'Orio, V ;
Gevenois, PA ;
Dondelinger, RF .
RADIOLOGY, 2006, 239 (03) :884-891
[6]   Focal Iodine Defects on Color-Coded Iodine Perfusion Maps of Dual-Energy Pulmonary CT Angiography Images: A Potential Diagnostic Pitfall [J].
Kang, Mi-Jin ;
Park, Chang Min ;
Lee, Chang-Hyun ;
Goo, Jin Mo ;
Lee, Hyun Ju .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 195 (05) :W325-W330
[7]   Dual-energy perfusion CT of non-diseased lung segments using dual-source CT: correlation with perfusion SPECT [J].
Kunihiro, Yoshie ;
Okada, Munemasa ;
Matsunaga, Naofumi ;
Sano, Yuichi ;
Kudomi, Shohei ;
Suga, Kazuyoshi ;
Kido, Shoji .
JAPANESE JOURNAL OF RADIOLOGY, 2013, 31 (02) :99-104
[8]   Potential of right to left ventricular volume ratio measured on chest CT for the prediction of pulmonary hypertension: correlation with pulmonary arterial systolic pressure estimated by echocardiography [J].
Lee, Heon ;
Kim, Seok Yeon ;
Lee, Soo Jeong ;
Kim, Jae Kyun ;
Reddy, Ryan P. ;
Schoepf, U. Joseph .
EUROPEAN RADIOLOGY, 2012, 22 (09) :1929-1936
[9]   Optimization of Contrast Material Delivery for Dual-Energy Computed Tomography Pulmonary Angiography in Patients With Suspected Pulmonary Embolism [J].
Nance, John W., Jr. ;
Henzler, Thomas ;
Meyer, Mathias ;
Apfaltrer, Paul ;
Braunagel, Margarita ;
Krissak, Radko ;
Schoepf, Uwe J. ;
Schoenberg, Stefan O. ;
Fink, Christian .
INVESTIGATIVE RADIOLOGY, 2012, 47 (01) :78-84
[10]   Volumetric evaluation of dual-energy perfusion CT for the assessment of intrapulmonary clot burden [J].
Okada, M. ;
Nakashima, Y. ;
Kunihiro, Y. ;
Sano, Y. ;
Suga, K. ;
Kido, S. ;
Matsunaga, N. .
CLINICAL RADIOLOGY, 2013, 68 (12) :E669-E675