Dosimetric characteristics of the new RadioCoil™ 103Pd wire line source for use in permanent brachytherapy implants

被引:30
|
作者
Meigooni, AS [1 ]
Zhang, H [1 ]
Clark, JR [1 ]
Rachabatthula, V [1 ]
Koona, RA [1 ]
机构
[1] Univ Kentucky, Albert B Chandler Med Ctr, Dept Radiat Med, Lexington, KY 40536 USA
关键词
brachytherapy; Pd-103; linear source; prostate; dosimetry;
D O I
10.1118/1.1809851
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Recently, a novel linear brachytherapy source in the form of a coiled wire has become available for use in interstitial implants of various treatment sites such as prostate gland. This source type employs a design completely different from that of most "seed" sources currently on the market, one which improves upon or eliminates several common problems with such sources. Dosimetric characteristics of these sources with active lengths 0.5 cm to 5.0 cm were determined for clinical application. For 0.5 cm and 1.0 cm active length sources, the dose rate constant, radial dose function, and two-dimensional (2D) anisotropy function were experimentally and theoretically determined following the updated AAPM Task Group 43 (TG-43U1) recommendations. Radial dose functions and/or "along-away" matrix functions were also obtained for sources with active lengths 2.0 cm to 5.0 cm. Measurements were performed with LiF thermoluminescent dosimeters in Solid Water(TM) phantoms. Measured data was compared to Monte Carlo simulated data in Solid Water(TM) utilizing the PTRAN code, version 7.43. After finding the data to be in agreement, Monte Carlo calculations were performed in liquid water to obtain clinically applicable dosimetric data as per TG-43U1 recommendations. The results indicated the dose rate constant of the 0.5 cm long Radio-Coil(TM) Pd-103 source in Solid Water(TM) to be 0.641 cGy h(-1) U-1 when measured, and 0.636 cGy h(-1) U-1 when simulated by Monte Carlo. The calculated dose rate constant in liquid water was found to be 0.650 cGy h(-1) U-1. These values are comparable to other commercially available sources. Complete dosimetric data and simulation results are described in this paper. Per TG-43U1, clinical treatment planning systems should utilize the values reported for liquid water. (C) 2004 American Association of Physicists in Medicine.
引用
收藏
页码:3095 / 3105
页数:11
相关论文
共 37 条
  • [1] Treatment-planning considerations for prostate implants with the new linear RadioCoil™ 103Pd brachytherapy source
    Meigooni, Ali S.
    Awan, Shahid B.
    Rachabatthula, Venkata
    Koona, Rafiq A.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2005, 6 (03): : 23 - 36
  • [2] Determination of dosimetric characteristics of OptiSeed™ a plastic brachytherapy 103Pd source
    Wang, ZL
    Hertel, NE
    APPLIED RADIATION AND ISOTOPES, 2005, 63 (03) : 311 - 321
  • [3] Dosimetric characteristics of the Best® double-wall 103Pd brachytherapy source
    Meigooni, AS
    Bharucha, Z
    Yoe-Sein, M
    Sowards, K
    MEDICAL PHYSICS, 2001, 28 (12) : 2568 - 2575
  • [4] Monte Carlo dosimetric characterization of the IsoAid ADVANTAGE 103Pd brachytherapy source
    Sowards, Keith T.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2007, 8 (02): : 18 - 25
  • [5] Dosimetric parameters of the new design 103Pd brachytherapy source based on Monte Carlo study
    Saidi, Pooneh
    Sadeghi, Mahdi
    Shirazi, Alireza
    Tenreiro, Claudio
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2012, 28 (01): : 13 - 18
  • [6] TG-43U1 parameterization of elongated RadioCoil 103Pd brachytherapy sources
    Dini, Sharifeh A.
    Awan, Shahid B.
    Dou, Kai
    Meigooni, Ali S.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2007, 8 (03): : 60 - 75
  • [7] Experimental and Monte Carlo dosimetric characterization of a 1 cm 103Pd brachytherapy source
    Reed, Joshua L.
    Rivard, Mark J.
    Micka, John A.
    Culberson, Wesley S.
    DeWerd, Larry A.
    BRACHYTHERAPY, 2014, 13 (06) : 657 - 667
  • [8] A directional 103Pd brachytherapy device: Dosimetric characterization and practical aspects for clinical use
    Rivard, Mark J.
    BRACHYTHERAPY, 2017, 16 (02) : 421 - 432
  • [9] Dosimetric aspects of 103Pd radioactive stent source
    Sadeghi, M.
    Kiavar, O.
    KERNTECHNIK, 2012, 77 (05) : 390 - 394
  • [10] 103Pd strings: Monte Carlo assessment of a new approach to brachytherapy source design
    Rivard, Mark J.
    Reed, Joshua L.
    DeWerd, Larry A.
    MEDICAL PHYSICS, 2014, 41 (01)