Determination of carbendazim in soil samples by anodic stripping voltammetry using a carbon fiber ultramicroelectrode

被引:35
作者
de la Huebra, MJG [1 ]
Hernández, P [1 ]
Nieto, O [1 ]
Ballesteros, Y [1 ]
Hernández, L [1 ]
机构
[1] Univ Autonoma Madrid, Fac Sci, Dept Analyt Chem & Instrumental Anal, E-28049 Madrid, Spain
来源
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY | 2000年 / 367卷 / 05期
关键词
D O I
10.1007/s002160000361
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A method for the determination of carbendazim (MBC) by anodic stripping voltammetry using a carbon fiber ultramicroelectrode was developed. The ultramicroelectrode was made in our laboratory and its electrochemical behavior was characterized by measuring the electrochemical response with a solution of potassium ferricyanide. The optimum parameters used for the determination of MBC are the following: 0.05 M phosphate buffer at pH 2.0 as supporting electrolyte; a scan rate of v = 10.00 V s(-1) and an accumulation potential of E-ac = 0.00 V. The MBC was determined in a soil sample with the method proposed and the results found were comparable to those obtained by HPLC.