Detection of zinc and lead in wine by potentiometric stripping on novel dental amalgam electrodes

被引:15
作者
Mikkelsen, O [1 ]
Nordhei, C [1 ]
Skogvold, SM [1 ]
Schroder, KH [1 ]
机构
[1] Norwegian Univ Sci & Technol, Dept Chem, N-7491 Trondheim, Norway
关键词
wine; zinc; lead; potentiometric stripping analyses (PSA); dental amalgam electrode;
D O I
10.1081/AL-200035832
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A simple method for detection of zinc and lead in wine by use of potentiometric stripping analyses (PSA) on. the dental amalgam electrode is introduced and demonstrated for 10 different wines, both red and white. The combination of PSA and the novel nontoxic electrode offers a fast and easy-to-use technique without matrix effects seen in, e.g., voltammetry. Concentrations of zinc in the range of approximately 2.1 x 10(-6) M to 11.7 x 10(-6) M (3.5% std. dev.) and lead in the range of 9.7 x 10(-8) M to 2.4 x 10(-7) M (3.5% std. dev.) were found in the actual wine samples. PSA measurements were verified against atomic adsorption spectroscopy analyses (AAS), and a good correlation factor was found (r(2) = 0.96). A simple speciation study was performed by measuring the amount of zinc and lead before and after the addition of acid, giving an approximate ratio between free and total amount of the metals. Estimated detection limits for zinc and lead were calculated to, respectively, 3.0 x 10(-7) M and 1.5 x 10(-8) M for 120 sec. of plating time.
引用
收藏
页码:2925 / 2936
页数:12
相关论文
共 43 条
  • [1] Sono-electroanalysis: Application to the detection of lead in wine
    Akkermans, RP
    Ball, JC
    Rebbitt, TO
    Marken, F
    Compton, RG
    [J]. ELECTROCHIMICA ACTA, 1998, 43 (23) : 3443 - 3449
  • [2] Alvarez EA, 1998, ELECTROANAL, V10, P917, DOI 10.1002/(SICI)1521-4109(199810)10:13<917::AID-ELAN917>3.0.CO
  • [3] 2-L
  • [4] STUDY OF LABILITY OF HEAVY-METALS IN WINES WITH DIFFERENT DEGREES OF AGING THROUGH DIFFERENTIAL-PULSE ANODIC-STRIPPING VOLTAMMETRY
    ARCOS, MT
    ANCIN, MC
    ECHEVERRIA, JC
    GONZALEZ, A
    GARRIDO, JJ
    [J]. JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 1993, 41 (12) : 2333 - 2339
  • [5] ARIEL M, 1964, J ELECTROANAL CHEM, V7, P307
  • [6] Evaluation of Pb-Spec® for flow-injection solid-phase extraction preconcentration for the determination of trace lead in water and wine by flame atomic absorption spectrometry
    Bakircioglu, Y
    Segade, SR
    Yourd, ER
    Tyson, JF
    [J]. ANALYTICA CHIMICA ACTA, 2003, 485 (01) : 9 - 18
  • [7] Polarography and voltammetry at mercury electrodes
    Barek, J
    Fogg, AG
    Muck, A
    Zima, J
    [J]. CRITICAL REVIEWS IN ANALYTICAL CHEMISTRY, 2001, 31 (04) : 291 - 309
  • [8] Carvalho ML, 1996, X-RAY SPECTROM, V25, P29, DOI 10.1002/(SICI)1097-4539(199601)25:1<29::AID-XRS134>3.0.CO
  • [9] 2-Z
  • [10] Pushing the detectability of voltammetry: how low can we go?
    Czae, MZ
    Wang, J
    [J]. TALANTA, 1999, 50 (05) : 921 - 928