Comparison of two-dimensional synthesized mammogram (2DSM) and conventional full-field digital mammogram (FFDM) for evaluation of breast cancer

被引:5
作者
Choi, Gayoung [1 ]
Woo, Ok Hee [1 ]
Shin, Hye Seon [1 ]
Jang, Seonah [2 ]
Cho, Kyu Ran [3 ]
Seo, Bo Kyoung [4 ]
机构
[1] Korea Univ, Guro Hosp, Diagnost Radiol, 148 Gurodongro, Seoul 08308, South Korea
[2] Korea Canc Ctr Hosp, Diagnost Radiol, 75 Nowon Ro, Seoul 01812, South Korea
[3] Korea Univ, Anam Hosp, Diagnost Radiol, 73 Inchon Ro, Seoul 02841, South Korea
[4] Korea Univ, Ansan Hosp, Diagnost Radiol, 123 Jeokgeum Ro, Ansan 15355, Gyeonggi Do, South Korea
关键词
RECONSTRUCTED PROJECTION IMAGES; OBSERVER-PERFORMANCE; TOMOSYNTHESIS; CALCIFICATIONS;
D O I
10.1016/j.clinimag.2017.03.004
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To compare the diagnostic efficacy of 2DSM and FFDM for evaluation of breast cancer. Materials and methods: A retrospective observer performance study was done by 3 breast radiologists. The diagnostic accuracy, image quality, and detailed lesion characterization of each 2DSM and FFDM were evaluated blindly to determine superior modality. Results: The diagnostic accuracy was not significantly different between two modalities. The image quality was superior in 2DSM (p-value 0.0362). Conclusions: 2DSM showed equivalent diagnostic accuracy and superior image quality to FFDM. Overall characterization of the lesion was better in 2DSM, and 2DSM showed superiority in evaluation of spiculated margins. (C) 2017 Elsevier Inc. All rights reserved.
引用
收藏
页码:170 / 174
页数:5
相关论文
共 19 条
[1]  
[Anonymous], 2011, HOLOGIC PROPRIETARY
[2]   Performance comparison of single-view digital breast tomosynthesis plus single-view digital mammography with two-view digital mammography [J].
Gennaro, Gisella ;
Hendrick, R. Edward ;
Ruppel, Patricia ;
Chersevani, Roberta ;
di Maggio, Cosimo ;
La Grassa, Manuela ;
Pescarini, Luigi ;
Polico, Ilaria ;
Proietti, Alessandro ;
Baldan, Enrica ;
Bezzon, Elisabetta ;
Pomerri, Fabio ;
Muzzio, Pier Carlo .
EUROPEAN RADIOLOGY, 2013, 23 (03) :664-672
[3]   Digital breast tomosynthesis versus digital mammography: a clinical performance study [J].
Gennaro, Gisella ;
Toledano, Alicia ;
di Maggio, Cosimo ;
Baldan, Enrica ;
Bezzon, Elisabetta ;
La Grassa, Manuela ;
Pescarini, Luigi ;
Polico, Ilaria ;
Proietti, Alessandro ;
Toffoli, Aida ;
Muzzio, Pier Carlo .
EUROPEAN RADIOLOGY, 2010, 20 (07) :1545-1553
[4]   Dose Reduction in Digital Breast Tomosynthesis (DBT) Screening using Synthetically Reconstructed Projection Images: An Observer Performance Study [J].
Gur, David ;
Zuley, Margarita L. ;
Anello, Maria I. ;
Rathfon, Grace Y. ;
Chough, Denise M. ;
Ganott, Marie A. ;
Hakim, Christiane M. ;
Wallace, Luisa ;
Lu, Amy ;
Bandos, Andriy I. .
ACADEMIC RADIOLOGY, 2012, 19 (02) :166-171
[5]   Digital Breast Tomosynthesis: Observer Performance Study [J].
Gur, David ;
Abrams, Gordon S. ;
Chough, Denise M. ;
Ganott, Marie A. ;
Hakim, Christiane M. ;
Perrin, Ronald L. ;
Rathfon, Grace Y. ;
Sumkin, Jules H. ;
Zuley, Margarita L. ;
Bandos, Andriy I. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2009, 193 (02) :586-591
[6]   Comparison of Tomosynthesis Plus Digital Mammography and Digital Mammography Alone for Breast Cancer Screening [J].
Haas, Brian M. ;
Kalra, Vivek ;
Geisel, Jaime ;
Raghu, Madhavi ;
Durand, Melissa ;
Philpotts, Liane E. .
RADIOLOGY, 2013, 269 (03) :694-700
[7]   Digital Mammography Imaging: Breast Tomosynthesis and Advanced Applications [J].
Helvie, Mark A. .
RADIOLOGIC CLINICS OF NORTH AMERICA, 2010, 48 (05) :917-+
[8]  
Kim SH, 2000, Journal of the Korean Radiological Society, V42, P1009
[9]  
Kim SJ, 2008, J KOREAN SOC BREAST, V5, P9
[10]   Calcifications in the Breast and Digital Breast Tomosynthesis [J].
Kopans, Daniel ;
Gavenonis, Sara ;
Halpern, Elkan ;
Moore, Richard .
BREAST JOURNAL, 2011, 17 (06) :638-644