Measurement System for Characterization of Gas and Particle Phase of High Temperature Combustion Aerosols

被引:14
作者
Deuerling, Christian F. [1 ]
Maguhn, Juergen [1 ]
Nordsieck, Hermann O. [2 ]
Warnecke, Ragnar [3 ]
Zimmermann, Ralf [1 ,4 ]
机构
[1] Helmholtz Res Ctr Munich, Inst Ecol Chem, D-85764 Neuherberg, Germany
[2] Bifa Environm Inst, Augsburg, Germany
[3] GKS Gemeinschaftskraftwerk Schweinfurt GmbH, Schweinfurt, Germany
[4] Univ Rostock, Inst Chem, Rostock, Germany
关键词
SIZE DISTRIBUTION; INCINERATION PLANT; EFFECTIVE DENSITY; ASH FORMATION; FINE; NUCLEATION; BOILERS; ALKALI; FLUE;
D O I
10.1080/02786820903325402
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
A measurement system was developed to sample and analyze the particle and gas phase of high temperature combustion aerosols up to a particle aerodynamic diameter of approximately 3 mm. The rapid changes of aerosol composition and concentration caused by the inhomogeneous fuel and changing burning conditions were accommodated by a combined measurement of both gas and particle phase and a synchronous measurement of two identical systems at two different positions at the boiler. Based on works reported earlier, an air-cooled dilution probe was designed and adapted to the corrosive composition of the combustion aerosol by use of a silica glass inlet and a ceramic porous tube diluter (PTD). Directly behind the probe, the raw gas is passing a cyclone which precipitates the coarse particles > 25 mu m, and is then split into a gas analysis and a particle analysis branch. The particle branch, after further dilution and cooling to ambient temperature, is split for a simultaneous analysis by an APS and a low pressure impactor (ELPI or BLPI). The whole sampling line is conditioned to 300 degrees C until final dilution and cooling to ambient temperature. The measurement system was employed at different incineration plants between 220 degrees C and 950 degrees C for various experiments, e. g., time resolved concentration analysis during soot blowing cleaning routine. The mass concentration balance, including the content of the inlet, achieved a 92% match of the total slag mass balance of the investigated plant.
引用
收藏
页码:1 / 9
页数:9
相关论文
共 32 条
  • [1] AUVINEN A, 2003, EUR AER C 2003 MADR, pS109
  • [2] Baron P.A., 2001, AEROSOL MEASUREMENT, V2nd
  • [3] BRUNNER T, 2006, THERMAL BIOMASS UTIL, V7, P26
  • [4] The formation of submicron aerosol particles, HCl and SO2 in straw-fired boilers
    Christensen, KA
    Stenholm, M
    Livbjerg, H
    [J]. JOURNAL OF AEROSOL SCIENCE, 1998, 29 (04) : 421 - 444
  • [5] CHRISTMANN E, 1999, DORST DRUCKFL SEM ZE, P174
  • [6] CIEZKI H, 1996, 32 JOINT PROP C LAK
  • [7] DIXKENS J, 1995, STAUB REINHALT LUFT, V55, P283
  • [8] Enders M, 2000, EUR J MINERAL, V12, P639
  • [9] Particle collection efficiency and particle re-entrainment of an electrostatic precipitator in a sewage sludge incineration plant
    Ferge, T
    Maguhn, J
    Felber, H
    Zimmermann, R
    [J]. ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2004, 38 (05) : 1545 - 1553
  • [10] The nucleation of aerosols in flue gases with a high content of alkali - A laboratory study
    Jensen, JR
    Nielsen, LB
    Schultz-Moller, C
    Wedel, S
    Livbjerg, H
    [J]. AEROSOL SCIENCE AND TECHNOLOGY, 2000, 33 (06) : 490 - 509