Impact of X-ray energy on absorbed dose assessed with Monte Carlo simulations in a mouse tumor and in nearest organs irradiated with kilovoltage X-ray beams

被引:4
作者
Hamdi, M. [1 ]
Mimi, M. [1 ]
Bentourkia, M. [2 ]
机构
[1] Univ Mostaganem, Dept Elect Engn, BP188-227, Mostaganem 27000, Algeria
[2] Univ Sherbrooke, Dept Nucl Med & Radiobiol, 3001,12th,Ave North, Sherbrooke, PQ J1H 5N4, Canada
来源
CANCER RADIOTHERAPIE | 2017年 / 21卷 / 03期
基金
加拿大自然科学与工程研究理事会; 加拿大创新基金会;
关键词
Dosimetry; Monte Carlo; Small animal; Tumor; X-rays; Photon interaction; SMALL ANIMAL RADIOTHERAPY; COMPUTED-TOMOGRAPHY; CONFORMAL RADIOTHERAPY; RADIATION-THERAPY; HOUNSFIELD UNITS; IMAGING RESEARCH; PHOTON BEAMS; CT; SYSTEM; GATE;
D O I
10.1016/j.canrad.2017.01.008
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose. - Radiotherapy treatments to local tumors are always associated with dose deposit in surrounding tissues and even in distant tissues not traversed by the radiation beams. In the present work, we demonstrate by Monte Carlo simulations the impact of radiation energy on absorbed dose in a lung tumor and in other secondary organs in a digital mouse. We also report the energy difference between simulations of monoenergetic and spectral radiations, and between CT-based and atlas-made digital mouse. Materials and methods. - We simulated seven monoenergetic and spectral radiation beams from 50 keV (or kVp) to 450 keV (or kVp). For each energy mode, the beams were generated along seven angles converging on the tumor. We assessed the absorbed dose in ten volumes including the lungs, the heart and the spine. Results. - The results showed an increase of absorbed dose as a function of energy with a lowest dose at 100 keV. In the secondary organs not traversed by the beams, the spinal cord received doses of 0.78% and 0.07%, and the spinal bone received 2.36% and 0.35% relative to those in the tumor, respectively at 50 keV and at 450 keV. A region in the heart not traversed by the beams received 2% of the dose to the tumor. Conclusions. - The optimal energy to the tumor with relatively reduced doses to other organs was achieved at energies around 200 key. At these energies, the surrounding of the tumor received lesser doses. Monoenergetic radiations were found to be more appropriate to target the tumor than spectral radiations produced by X-ray tubes, and CT-based digital mouse was more realistic than atlas-based mouse since it accounts for tissue heterogeneity. (C) 2017 Societe francaise de radiotherapie oncologique (SFRO). Published by Elsevier Masson SAS. All rights reserved.
引用
收藏
页码:190 / 198
页数:9
相关论文
共 48 条
[1]   Software architecture for multi-bed FDK-based reconstruction in X-ray CT scanners [J].
Abella, M. ;
Vaquero, J. J. ;
Sisniega, A. ;
Pascau, J. ;
Udias, A. ;
Garcia, V. ;
Vidal, I. ;
Desco, M. .
COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2012, 107 (02) :218-232
[2]  
[Anonymous], 1997, E193597 ASTM
[3]   Small animal computed tomography Imaging [J].
Bartling, Soenke H. ;
Stiller, Wolfram ;
Semmler, Wolfhard ;
Kiessling, Fabian .
CURRENT MEDICAL IMAGING, 2007, 3 (01) :45-59
[4]   Modality comparison for small animal radiotherapy: A simulation study [J].
Bazalova, Magdalena ;
Nelson, Geoff ;
Noll, John M. ;
Graves, Edward E. .
MEDICAL PHYSICS, 2014, 41 (01)
[5]   The importance of tissue segmentation for dose calculations for kilovoltage radiation therapy [J].
Bazalova, Magdalena ;
Graves, Edward E. .
MEDICAL PHYSICS, 2011, 38 (06) :3039-3049
[6]   A stoichiometric calibration method for dual energy computed tomography [J].
Bourque, Alexandra E. ;
Carrier, Jean-Francois ;
Bouchard, Hugo .
PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (08) :2059-2088
[7]   ROOT - An object oriented data analysis framework [J].
Brun, R ;
Rademakers, F .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1997, 389 (1-2) :81-86
[8]   Planning, delivery, and quality assurance of intensity-modulated radiotherapy using dynamic multileaf collimator: A strategy for large-scale implementation for the treatment of carcinoma of the prostate [J].
Burman, C ;
Chui, CS ;
Kutcher, G ;
Leibel, S ;
Zelefsky, M ;
LoSasso, T ;
Spirou, S ;
Wu, QW ;
Yang, J ;
Stein, J ;
Mohan, R ;
Fuks, Z ;
Ling, CC .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1997, 39 (04) :863-873
[9]  
Chen SC, 2012, MALAYS J MED SCI, V19, P22
[10]   Report of the AAPM Task Group No. 105: Issues associated with clinical implementation of Monte Carlo-based photon and electron external beam treatment planning [J].
Chetty, Indrin J. ;
Curran, Bruce ;
Cygler, Joanna E. ;
DeMarco, John J. ;
Ezzell, Gary ;
Faddegon, Bruce A. ;
Kawrakow, Iwan ;
Keall, Paul J. ;
Liu, Helen ;
Ma, C. -M. Charlie ;
Rogers, D. W. O. ;
Seuntjens, Jan ;
Sheikh-Bagheri, Daryoush ;
Siebers, Jeffrey V. .
MEDICAL PHYSICS, 2007, 34 (12) :4818-4853