Use of Anti-Skid Material and Patient-Positioning To Prevent Patient Shifting during Robotic-Assisted Gynecologic Procedures

被引:35
作者
Klauschie, Jennifer [1 ]
Wechter, M. E. [1 ]
Jacob, K. [1 ]
Zanagnolo, V. [1 ]
Montero, R. [1 ]
Magrina, J. [1 ]
Kho, R. [1 ]
机构
[1] Mayo Clin Arizona, Dept Gynecol Surg, Phoenix, AZ 85054 USA
关键词
Antiskid material; Laparoscopy; Robotics; Shoulder braces; SHOULDER RESTRAINTS; NERVE INJURIES; ARM ABDUCTION; NEUROPATHIES; SURGERY;
D O I
10.1016/j.jmig.2010.03.013
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Study Objective: To estimate patient shifting with the current practice of use of an antiskid material and patient positioning during robotic procedures in gynecology. Design: Pilot observational study (Canadian Task Force classification). Setting: Tertiary referral center. Patients: Twenty-two women undergoing robotic-assisted gynecologic procedures. Intervention: Antiskid material (egg-crate pink foam) was placed beneath patients and patient positioning was used during robotic-assisted procedures. Measurements and Main Results: Patient position was marked before and after surgery. Measurements of shift distance before and after surgery were determined for each patient. Median (range) shift distance was 1.3 (0-7.5) cm. There was no significant association between shift in position and either body mass index or duration of the Trendelenburg position. No shoulder neuropathic injuries were observed during the study. Conclusion: Minimal patient shifting is observed with the use of an antiskid material and patient positioning described, without the use of shoulder braces and straps. Journal of Minimally Invasive Gynecology (2010) 17, 504-507 (c) 2010 AAGL. All rights reserved.
引用
收藏
页码:504 / 507
页数:4
相关论文
共 12 条
[1]   Laparoscopic positioning and nerve injuries [J].
Barnett, J. Cory ;
Hurd, William W. ;
Rogers, Robert M., Jr. ;
Williams, Ned L. ;
Shapiro, Scott A. .
JOURNAL OF MINIMALLY INVASIVE GYNECOLOGY, 2007, 14 (05) :664-672
[2]   Prevention of femoral nerve injuries in gynecologic surgery [J].
Chan, JK ;
Manetta, A .
AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2002, 186 (01) :1-7
[3]   Shoulder restraints as a potential cause for stretch neuropathies: Biomechanical support for the impact of shoulder girdle depression and arm abduction on nerve strain [J].
Coppieters, MW .
ANESTHESIOLOGY, 2006, 104 (06) :1351-1352
[4]   Positioning in anesthesiology - Toward a better understanding of stretch-induced perioperative neuropathies [J].
Coppieters, MW ;
Van de Velde, M ;
Stappaerts, KH .
ANESTHESIOLOGY, 2002, 97 (01) :75-81
[5]   Shoulder supports, brachial plexus injury and head-down tilt [J].
Craig, J .
ANAESTHESIA, 2004, 59 (02) :196-196
[6]   USE OF SHOULDER RESTRAINTS DURING ARM ABDUCTION AND STEEP TRENDELENBURGS POSITION [J].
GOSKOWICZ, R .
ANESTHESIOLOGY, 1995, 83 (06) :1377-1377
[7]  
HEWER CL, 1953, LANCET, V264, P522
[8]  
HOWKINS J, 1952, LANCET, V263, P759
[9]   Minimizing the risk of neurologic injury in gynecologic surgery [J].
Irvin, W ;
Andersen, W ;
Taylor, P ;
Rice, L .
OBSTETRICS AND GYNECOLOGY, 2004, 103 (02) :374-382
[10]   A case of bilateral brachial plexus palsy due to shoulder braces [J].
Kent, Christopher D. ;
Cheney, Frederick W. .