Accuracy of a New Pulse Oximetry in Detection of Arterial Oxygen Saturation and Heart Rate Measurements: The SOMBRERO Study

被引:8
作者
Marinari, Stefano [1 ]
Volpe, Pasqualina [2 ]
Simoni, Marzia [3 ]
Aventaggiato, Matteo
De Benedetto, Fernando [4 ]
Nardini, Stefano [5 ]
Sanguinetti, Claudio M. [6 ]
Palange, Paolo [7 ]
机构
[1] G Mazzini Hosp, Resp Dis Unit, I-64100 Teramo, Italy
[2] Presidio PneumoTisiol Terr ASL 02, I-66100 Chieti, Italy
[3] CNR, Inst Clin Physiol, I-56124 Pisa, Italy
[4] FISAR Fdn, Fdn Salute Ambiente & Respiro, I-66100 Chieti, Italy
[5] Italian Multidisciplinary Resp Soc, I-20127 Milan, Italy
[6] Italian Multidisciplinary Resp Soc, Editorial Act, I-20127 Milan, Italy
[7] Sapienza Univ, Umberto Hosp, Div Resp Dis, Dept Publ Hlth & Infect Dis, I-00161 Rome, Italy
关键词
wrist-watch pulsoximeter; chronic cardiac diseases; chronic respiratory diseases; heart rate; pulse oxygen saturation; reflective pulseoximeter; SpO(2); IDIOPATHIC PULMONARY-FIBROSIS; SYSTEMIC INFLAMMATION; LUNG-FUNCTION; HOME; EXACERBATIONS; MORTALITY; FAILURE; COMORBIDITY; TELEHEALTH; OUTCOMES;
D O I
10.3390/s22135031
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Early diagnosis and continuous monitoring of respiratory failure (RF) in the course of the most prevalent chronic cardio-vascular (CVD) and respiratory diseases (CRD) are a clinical, unresolved problem because wearable, non-invasive, and user-friendly medical devices, which could grant reliable measures of the oxygen saturation (SpO(2)) and heart rate (HR) in real-life during daily activities are still lacking. In this study, we investigated the agreement between a new medical wrist-worn device (BrOxy M) and a reference, medical pulseoximeter (Nellcor PM 1000N). Twelve healthy volunteers (aged 20-51 years, 84% males, 33% with black skin, obtaining, during the controlled hypoxia test, the simultaneous registration of 219 data pairs, homogeneously deployed in the levels of Sat.O-2 97%, 92%, 87%, 82% [ISO 80601-2-61:2017 standard (paragraph EE.3)]) were included. The paired T test 0 and the Bland-Altman plot were performed to assess bias and accuracy. SpO(2) and HR readings by the two devices resulted significantly correlated (r = 0.91 and 0.96, p < 0.001, respectively). Analyses excluded the presence of proportional bias. For SpO(2), the mean bias was -0.18% and the accuracy (A(RMS)) was 2.7%. For HR the mean bias was 0.25 bpm and the A(RMS)3.7 bpm. The sensitivity to detect SpO(2) <= 94% was 94.4%. The agreement between BrOxy M and the reference pulse oximeter was "substantial" (for SpO(2) cut-off 94% and 90%, k = 0.79 and k = 0.80, respectively). We conclude that BrOxy M demonstrated accuracy, reliability and consistency in measuring SpO(2) and HR, being fully comparable with a reference medical pulseoxymeter, with no adverse effects. As a wearable device, Broxy M can measure continually SpO(2) and HR in everyday life, helping in detecting and following up CVD and CRD subjects.
引用
收藏
页数:18
相关论文
共 60 条
  • [1] Airflow obstruction, lung function, and risk of incident heart failure: the Atherosclerosis Risk in Communities (ARIC) study
    Agarwal, Sunil K.
    Heiss, Gerardo
    Barr, R. Graham
    Chang, Patricia P.
    Loehr, Laura R.
    Chambless, Lloyd E.
    Shahar, Eyal
    Kitzman, Dalane W.
    Rosamond, Wayne D.
    [J]. EUROPEAN JOURNAL OF HEART FAILURE, 2012, 14 (04) : 414 - 422
  • [2] [Anonymous], UNLOCK HLTH INSIGHTS
  • [3] [Anonymous], NEXT GENERATION HLTH
  • [4] [Anonymous], TECHNOLOGY THATS BUI
  • [5] [Anonymous], WATCHING YOU
  • [6] [Anonymous], OXITONE 1000M WORLDS
  • [7] Anzueto A, 2009, Int J Chron Obstruct Pulmon Dis, V4, P245
  • [8] Heart rate variability in patients with sleep-related breathing disorders
    Bauer, T
    Ewig, S
    Schafer, H
    Jelen, E
    Omran, H
    Luderitz, B
    [J]. CARDIOLOGY, 1996, 87 (06) : 492 - 496
  • [9] STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
    BLAND, JM
    ALTMAN, DG
    [J]. LANCET, 1986, 1 (8476) : 307 - 310
  • [10] The impact of concurrent heart failure on prognosis in patients with chronic obstructive pulmonary disease
    Boudestein, Laura C. M.
    Rutten, Frans H.
    Cramer, Maarten J.
    Lammers, Jan Willem J.
    Hoes, Arno W.
    [J]. EUROPEAN JOURNAL OF HEART FAILURE, 2009, 11 (12) : 1182 - 1188